3 About the system

Operation manual

5

CTXF20~35C5V1B
Daikin room air conditioners
3P520336-11K – 2020.08

WARNING

▪ Do  NOT  modify,  disassemble,  remove,  reinstall  or

repair  the  unit  yourself  as  incorrect  dismantling  or
installation may cause an electric shock or fire. Contact
your dealer.

▪ In case of accidental refrigerant leaks, make sure there

are  no  naked  flames.  The  refrigerant  itself  is  entirely
safe,  non-toxic  and  mildly  flammable,  but  it  will
generate  toxic  gas  when  it  accidentally  leaks  into  a
room  where  combustible  air  from  fan  heaters,  gas
cookers,  etc.  is  present.  Always  have  qualified  service
personnel  confirm  that  the  point  of  leakage  has  been
repaired or corrected before resuming operation.

INFORMATION

The  following  figures  are  just  examples  and  may  NOT
completely match your system layout.

a

c d

ON/OFF

f

g

l

h

i

k

j

e

b

a

Air inlet

b

Air outlet

c

Flap (horizontal blade)

d

Louvers (vertical blades)

e

Front panel

f

Model name plate

g

Room temperature sensor

h

Signal receiver

i

Operation indicator (green)

j

Timer lamp (orange)

k

Indoor unit ON/OFF switch

l

Air filter

ON/OFF button

If the user interface is missing, you can use the ON/OFF button on
the  indoor  unit  to  start/stop  operation.  When  operation  is  started
using this button, the following settings are used:

▪ Operation mode = Automatic

▪ Temperature setting = 25°C

▪ Airflow rate = Automatic

3.2

About the user interface

Direct  sunlight.

  Do  NOT  expose  the  user  interface  to  direct

sunlight.

Dust.

  Dust  on  the  signal  transmitter  or  receiver  will  reduce

sensitivity. Wipe off dust with a soft cloth.

Fluorescent  lights.

  Signal  communication  might  be  disabled  if

fluorescent  lamps  are  in  the  room.  In  that  case,  contact  your
installer.

Other  appliances.

  If  the  user  interface  signals  operate  other

appliances, move the other appliances, or contact your installer.

Curtains.

 Make sure that the signal between the unit and the user

interface is NOT blocked by curtains or other objects.

NOTICE

▪ Do NOT drop the user interface.

▪ Do NOT let the user interface get wet.

3.2.1

Components: User interface

b

d

c

f

h

e

m

l

k

i

j

a

g

a

Signal transmitter

b

LCD display

c

ON/OFF button

d

Fan setting button

e

Temperature adjustment button

f

Swing button

g

Timer cancel button

h

ON timer button

i

OFF timer button

j

Comfort airflow button

k

Econo button

l

Mode selector button

m

Powerful button

3.2.2

Status: User interface LCD

Icon

Description

Operation mode = Automatic

Operation mode = Drying

Operation mode = Heating

Operation mode = Cooling

Operation mode = Fan only

Powerful operation is active

Econo operation is active

Operation is active

Summary of Contents for CTXF20C5V1B

Page 1: ...Operation manual Daikin room air conditioners English Operation manual Daikin room air conditioners CTXF20C5V1B CTXF25C5V1B CTXF35C5V1B...

Page 2: ...es while the air conditioner is not in operation 12 8 2 Solving problems based on error codes 12 9 Disposal 13 1 About the documentation 1 1 About this document Thank you for purchasing this product P...

Page 3: ...l symbols are Pb lead 0 004 Waste batteries must be treated at a specialized treatment facility for reuse By ensuring waste batteries are disposed of correctly you will help to prevent potential negat...

Page 4: ...er a long use check the unit stand and fitting for damage If damaged the unit may fall and result in injury CAUTION Do NOT touch the heat exchanger fins These fins are sharp and could result in cuttin...

Page 5: ...top operation When operation is started using this button the following settings are used Operation mode Automatic Temperature setting 25 C Airflow rate Automatic 3 2 About the user interface Direct s...

Page 6: ...eep Setting changes Long beep Operation stops 4 Before operation 4 1 To mount the user interface holder 2 b c a a User interface b Screws field supply c User interface holder 1 Choose a place where th...

Page 7: ...ing Description Automatic The system cools down or heats up a room to the temperature setpoint It automatically switches between cooling and heating if necessary Drying The system decreases the humidi...

Page 8: ...d position press when the flap reaches the desired position Result disappears from the LCD To adjust the louvers vertical blades 1 Hold 1 or both knobs and move the louvers a a a Knobs INFORMATION Whe...

Page 9: ...urs 2 Press to stop Result disappears from the LCD and the timer lamp goes off To start stop OFF timer operation 1 Press to start Result is displayed on the LCD and the timer lamp lights up INFORMATIO...

Page 10: ...leaning materials or means to accelerate the defrosting process other than those recommended by the manufacturer Be aware that the refrigerant inside the system is odourless NOTICE Maintenance MUST be...

Page 11: ...It is recommended to have periodical maintenance performed by a specialist For specialist maintenance contact your dealer Maintenance costs shall be borne by the customer In certain operating conditio...

Page 12: ...otection 8 2 Solving problems based on error codes Fault diagnosis by user interface If the unit runs into a problem you can identify the fault by checking the error code by the user interface It is i...

Page 13: ...6 11K 2020 08 9 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units MUS...

Page 14: ......

Page 15: ......

Page 16: ...ANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P520336 11K 2020 08 Copyright 2...

Reviews: