background image

Table of contents

Operation manual

2

CTXF20~35C5V1B

Daikin room air conditioners

3P520336-11K – 2020.08

Table of contents

1 About the documentation

2

1.1

About this document..................................................................

2

2 User safety instructions

2

2.1

General......................................................................................

2

2.2

Instructions for safe operation ...................................................

3

3 About the system

4

3.1

Indoor unit .................................................................................

4

3.2

About the user interface ............................................................

5

3.2.1

Components: User interface .......................................

5

3.2.2

Status: User interface LCD .........................................

5

3.2.3

To operate the user interface......................................

6

4 Before operation

6

4.1

To mount the user interface holder ...........................................

6

4.2

To insert the batteries................................................................

6

4.3

To turn on the power supply......................................................

6

5 Operation

6

5.1

Operation range ........................................................................

6

5.2

When to use which feature........................................................

7

5.3

Operation mode and temperature setpoint................................

7

5.3.1

To start/stop operation mode and to set the
temperature.................................................................

7

5.3.2

Airflow rate ..................................................................

7

5.3.3

Airflow direction...........................................................

8

5.3.4

Comfort airflow operation............................................

8

5.3.5

Powerful operation ......................................................

8

5.3.6

Econo operation..........................................................

9

5.3.7

OFF/ON timer operation .............................................

9

6 Energy saving and optimum operation

9

7 Maintenance and service

10

7.1

Overview: Maintenance and service .........................................

10

7.2

To clean the indoor unit and user interface ...............................

10

7.3

To clean the front panel.............................................................

11

7.4

About the air filters ....................................................................

11

7.5

To clean the air filters ................................................................

11

7.6

To take following items into account before a long idle period..

11

8 Troubleshooting

11

8.1

Symptoms that are NOT system malfunctions ..........................

12

8.1.1

Symptom: A sound like water flowing is heard ........... 12

8.1.2

Symptom: A blowing sound is heard........................... 12

8.1.3

Symptom: A ticking sound is heard............................. 12

8.1.4

Symptom: A whistling sound is heard ......................... 12

8.1.5

Symptom: A clicking sound during operation or idle
time is heard ............................................................... 12

8.1.6

Symptom: A clapping sound is heard ......................... 12

8.1.7

Symptom: The outdoor fan rotates while the air
conditioner is not in operation ..................................... 12

8.2

Solving problems based on error codes....................................

12

9 Disposal

13

1

About the documentation

1.1

About this document

Thank you for purchasing this product. Please:

▪ Read  the  documentation  carefully  before  operating  the  user

interface to ensure the best possible performance.

▪ Request the installer to inform you about the settings that he used

to  configure  your  system.  Check  if  he  has  filled  in  the  installer
settings tables. If not, request him to do so.

▪ Keep the documentation for future reference.

Target audience

End users

INFORMATION

This appliance is intended to be used by expert or trained
users  in  shops,  in  light  industry,  and  on  farms,  or  for
commercial and household use by lay persons.

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety  instructions  that  you  must  read  before  operating  your

system

▪ Format: Paper (in the box of the indoor unit)

Operation manual:

▪ Quick guide for basic usage

▪ Format: Paper (in the box of the indoor unit)

User reference guide:

▪ Detailed  step-by-step  instructions  and  background  information

for basic and advanced usage

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your installer.

The original documentation is written in English. All other languages
are translations.

2

User safety instructions

Always observe the following safety instructions and regulations.

2.1

General

WARNING

If you are NOT sure how to operate the
unit, contact your installer.

WARNING

Children aged from 8 years and above
and persons with reduced physical,
sensory or mental capabilities or lack
of experience and knowledge can only
use this appliance if they have been

Summary of Contents for CTXF20C5V1B

Page 1: ...Operation manual Daikin room air conditioners English Operation manual Daikin room air conditioners CTXF20C5V1B CTXF25C5V1B CTXF35C5V1B...

Page 2: ...es while the air conditioner is not in operation 12 8 2 Solving problems based on error codes 12 9 Disposal 13 1 About the documentation 1 1 About this document Thank you for purchasing this product P...

Page 3: ...l symbols are Pb lead 0 004 Waste batteries must be treated at a specialized treatment facility for reuse By ensuring waste batteries are disposed of correctly you will help to prevent potential negat...

Page 4: ...er a long use check the unit stand and fitting for damage If damaged the unit may fall and result in injury CAUTION Do NOT touch the heat exchanger fins These fins are sharp and could result in cuttin...

Page 5: ...top operation When operation is started using this button the following settings are used Operation mode Automatic Temperature setting 25 C Airflow rate Automatic 3 2 About the user interface Direct s...

Page 6: ...eep Setting changes Long beep Operation stops 4 Before operation 4 1 To mount the user interface holder 2 b c a a User interface b Screws field supply c User interface holder 1 Choose a place where th...

Page 7: ...ing Description Automatic The system cools down or heats up a room to the temperature setpoint It automatically switches between cooling and heating if necessary Drying The system decreases the humidi...

Page 8: ...d position press when the flap reaches the desired position Result disappears from the LCD To adjust the louvers vertical blades 1 Hold 1 or both knobs and move the louvers a a a Knobs INFORMATION Whe...

Page 9: ...urs 2 Press to stop Result disappears from the LCD and the timer lamp goes off To start stop OFF timer operation 1 Press to start Result is displayed on the LCD and the timer lamp lights up INFORMATIO...

Page 10: ...leaning materials or means to accelerate the defrosting process other than those recommended by the manufacturer Be aware that the refrigerant inside the system is odourless NOTICE Maintenance MUST be...

Page 11: ...It is recommended to have periodical maintenance performed by a specialist For specialist maintenance contact your dealer Maintenance costs shall be borne by the customer In certain operating conditio...

Page 12: ...otection 8 2 Solving problems based on error codes Fault diagnosis by user interface If the unit runs into a problem you can identify the fault by checking the error code by the user interface It is i...

Page 13: ...6 11K 2020 08 9 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units MUS...

Page 14: ......

Page 15: ......

Page 16: ...ANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P520336 11K 2020 08 Copyright 2...

Reviews: