WARNING

The refrigerant inside the unit is mildly
flammable, but normally does NOT
leak. If the refrigerant leaks in the room
and comes in contact with fire from a
burner, a heater, or a cooker, this may
result in fire, or the formation of a
harmful gas.

Turn off any combustible heating
devices, ventilate the room, and
contact the dealer where you
purchased the unit.

Do NOT use the unit until a service
person confirms that the part from
which the refrigerant leaked has been
repaired.

WARNING

▪ Do NOT pierce or burn refrigerant

cycle parts.

▪ Do NOT use cleaning materials or

means to accelerate the defrosting
process other than those
recommended by the manufacturer.

▪ Be aware that the refrigerant inside

the system is odourless.

WARNING

The appliance shall be stored in a
room without continuously operating
ignition sources (example: open
flames, an operating gas appliance or
an operating electric heater).

DANGER: RISK OF
ELECTROCUTION

To clean the air conditioner or air filter,
be sure to stop operation and turn all
power supplies off. Otherwise, an
electric shock and injury may result.

CAUTION

After a long use, check the unit stand
and fitting for damage. If damaged, the
unit may fall and result in injury.

CAUTION

Do NOT touch the heat exchanger fins.
These fins are sharp and could result
in cutting injuries.

WARNING

Be careful with ladders when working
in high places.

DANGER: RISK OF
ELECTROCUTION

Before cleaning, be sure to stop the
operation, turn the breaker off or pull
out the supply cord. Otherwise, an
electric shock and injury may result.

WARNING

Stop operation and shut off the
power if anything unusual occurs
(burning smells etc.).

Leaving the unit running under such
circumstances may cause breakage,
electric shock or fire. Contact your
dealer.

CAUTION

This  unit  is  equipped  with  electrically  powered  safety
measures,  such  as  a  refrigerant  leak  detector.  In  order  to
be  effective,  the  unit  must  be  electrically  powered  at  all
times after installation, except for short service periods.

3

About the system

WARNING: MILDLY FLAMMABLE MATERIAL

The refrigerant inside this unit is mildly flammable.

NOTICE

Do  NOT  use  the  system  for  other  purposes.  In  order  to
avoid  any  quality  deterioration,  do  NOT  use  the  unit  for
cooling  precision  instruments,  food,  plants,  animals,  or
works of art.

3.1

Indoor unit

CAUTION

Do  NOT  insert  fingers,  rods  or  other  objects  into  the  air
inlet or outlet. When the fan is rotating at high speed, it will
cause injury.

INFORMATION

The sound pressure level is less than 70 dBA.

Summary of Contents for CTXF20C5V1B

Page 1: ...Operation manual Daikin room air conditioners English Operation manual Daikin room air conditioners CTXF20C5V1B CTXF25C5V1B CTXF35C5V1B...

Page 2: ...es while the air conditioner is not in operation 12 8 2 Solving problems based on error codes 12 9 Disposal 13 1 About the documentation 1 1 About this document Thank you for purchasing this product P...

Page 3: ...l symbols are Pb lead 0 004 Waste batteries must be treated at a specialized treatment facility for reuse By ensuring waste batteries are disposed of correctly you will help to prevent potential negat...

Page 4: ...er a long use check the unit stand and fitting for damage If damaged the unit may fall and result in injury CAUTION Do NOT touch the heat exchanger fins These fins are sharp and could result in cuttin...

Page 5: ...top operation When operation is started using this button the following settings are used Operation mode Automatic Temperature setting 25 C Airflow rate Automatic 3 2 About the user interface Direct s...

Page 6: ...eep Setting changes Long beep Operation stops 4 Before operation 4 1 To mount the user interface holder 2 b c a a User interface b Screws field supply c User interface holder 1 Choose a place where th...

Page 7: ...ing Description Automatic The system cools down or heats up a room to the temperature setpoint It automatically switches between cooling and heating if necessary Drying The system decreases the humidi...

Page 8: ...d position press when the flap reaches the desired position Result disappears from the LCD To adjust the louvers vertical blades 1 Hold 1 or both knobs and move the louvers a a a Knobs INFORMATION Whe...

Page 9: ...urs 2 Press to stop Result disappears from the LCD and the timer lamp goes off To start stop OFF timer operation 1 Press to start Result is displayed on the LCD and the timer lamp lights up INFORMATIO...

Page 10: ...leaning materials or means to accelerate the defrosting process other than those recommended by the manufacturer Be aware that the refrigerant inside the system is odourless NOTICE Maintenance MUST be...

Page 11: ...It is recommended to have periodical maintenance performed by a specialist For specialist maintenance contact your dealer Maintenance costs shall be borne by the customer In certain operating conditio...

Page 12: ...otection 8 2 Solving problems based on error codes Fault diagnosis by user interface If the unit runs into a problem you can identify the fault by checking the error code by the user interface It is i...

Page 13: ...6 11K 2020 08 9 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units MUS...

Page 14: ......

Page 15: ......

Page 16: ...ANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P520336 11K 2020 08 Copyright 2...

Reviews: