8

CARE AND CLEANING

CAUTION

Only a qualified service person is allowed to perform maintenance.

Before cleaning, be sure to stop the operation and turn the breaker OFF.

Remove the air filter when connecting the duct.

Cleaning the air filter.

1. Removing the air filter.

Rear suction
Pull the bottom side of the air filter backwards, over the 2 bends.

Bottom suction
Pull the filter over the two bends situated at the backside of the unit.

2. Cleaning the air filter.

Remove dust from the air filter using a vacuum cleaner and gently rinse them in cool
water. Do not use detergent or hot water to avoid filter shrinking or deformation. After
cleaning dry them in the shade.

3. Replacing the air filter.

Rear suction
Hook the filter behind the flap situated at the top of the unit and push the other side gently over the 2 bends.

Bottom suction
Hook the filter behind the flap situated at the middle of
the unit and push the other side gently over the 2
bends.

Cleaning the drain pan

Clean the drain pan periodically, or drain piping may be clogged with dust and may result in water leakage.
Ask your DAIKIN dealer to clean them.

If the ambient air of indoor unit is so dusty, install the optional Dust Cover which prevent dust from falling into drain pan.

CAUTION

Do not operate the air conditioner without filters, this to avoid dust accummulation inside the unit.

Do not remove the air filter except when cleaning.
Unnecessary handling may damage the filter.

Do not use gasoline, benzene, thinner, polishing powder, liquid insecticide, It may cause discoloring or warping.

Do not let the indoor unit get wet. It may cause an electric shock or a fire.

Operation with dusty air filters lowers the cooling and heating capacity and wastes energy.

The suction grille is option.

Do not use water or air of 50°C or higher for cleaning air filters and outside panels.

In case of rear-suction.

Filter

Main unit

Attach the filter 
to the main unit 
while pushing 
down on the 
tabs.

In case of bottom-suction.

Summary of Contents for CDKS25BVMB

Page 1: ...plit R 410A Fran ais Manuel d installation S rie split R 410A Italiano Manuale d installazione Serie Multiambienti R 410A Nederlands Montagehandleiding R 410A Split systeem Portugues Manual de Instala...

Page 2: ...eceive no external stresses Incomplete connections or clamping may cause terminal overheating or fire After connecting interconnecting and supply wiring be sure to shape the cables so that they do not...

Page 3: ...gh to support the weight of the unit If there is a risk that the ceiling is not strong enough reinforce the ceiling before installing the unit Select the signal receiver mounting location within the s...

Page 4: ...he suspension bolt positions Install the suspension bolts Use M10 size bolts for the suspension bolts In order to reinforce the ceiling bearing the weight of the unit use anchors when installing onto...

Page 5: ...nd below the hanger brackets to secure them NOTE Use washers when mounting with M8 bolts Use a water level or water filled vinyl tubes to check that the unit is level at all four corners as shown in t...

Page 6: ...g into the system as this would reduce the lifetime of the units Never use piping which has been used for previous installations Only use parts which are delivered with the unit Do never install a dri...

Page 7: ...fittings observe the following Insulation material Polyethylene foam Heat transfer rate 0 041 to 0 052kW mK 0 035 to 0 045 kcal mh C Refrigerant gas pipe s surface temperature reaches 110 C max Choos...

Page 8: ...y screw wires to the corresponding terminals 3 Connect the earth wires to the corresponding terminals 4 Pull wires to make sure that they are securely latched up then retain wires with wire retainer 5...

Page 9: ...e of the unit and push the other side gently over the 2 bends Cleaning the drain pan Clean the drain pan periodically or drain piping may be clogged with dust and may result in water leakage Ask your...

Page 10: ...power in its standby mode If the system is not to be used for some time after installation shut off the circuit breaker to eliminate unnecessary power consumption If the circuit breaker trips to shut...

Page 11: ...2P098794 3 M02B075 0210 HT...

Reviews: