The following symptoms do not indi-

cate air conditioner malfunction

I.

THE SYSTEM DOES NOT OPERATE

• The system does not restart immediately 

after the ON/OFF button is pressed.

If the OPERATION lamp lights, the system 
is in normal condition. It does not restart 
immediately because a safety device 
operates to prevent overload of the sys-
tem. After 3 minutes, the system will turn 
on again automatically.

• The system does not restart immedi-

ately when TEMPERATURE SETTING 
button is returned to the former posi-
tion after pushing the button.

It does not restart immediately because a 
safety device operates to prevent overload 
of the system. After 3 minutes, the system 
will turn on again automatically.

• If the reception beep is rapidly repeated 

3 times (It sounds only twice when 
operating normally.)

Control is set to the optional controller for 
centralized control.

• If the defrost lamp on the indoor unit’s 

display is lit when heating is started.

This indication is to warn against cold air 
being blown from the unit.  There is 
nothing wrong with the equipment.

I.

  EMERGENCY STOP

When the air conditioner stops in emergency, 
the run lamp on the indoor unit starts blinking. 
Take the following steps yourself to read the 
malfunction code that appears on the dis-
play. Contact your dealer with this code. It will 
help pinpoint the cause of the trouble, speed-
ing up the repair.

6. NOT MALFUNCTION OF 

THE AIR CONDITIONER

7. HOW TO DIAGNOSE 

TROUBLE SPOTS

Press the INSPECTION/TEST button 
to select the inspection mode “

”.

” appears on display and blinks. “UNIT” 

lights up.

Press PROGRAMMING TIMER BUT-

TON and change the unit number.

Press to change the unit number until the 
indoor unit beeps and perform the following 
operation according to the number of beeps.

Number of beeps

3 short beeps .....Perform all steps from 

 

to .

1 short beep .......Perform 

 and 

 steps

1 long beep ........Normal state

Press OPERATION MODE SELECTOR 

BUTTON

” on the left-hand of the malfunction code 

blinks. 

Press PROGRAMMING TIMER BUT-

TON and change the malfunction code.

Press until the indoor unit beeps twice.

1

TEST

2

DOWN

UP

3

6

3

6

MODE

3

4

DOWN

UP

01_EN_3P107422-10F.fm  Page 10  Wednesday, August 31, 2005  1:44 PM

Summary of Contents for BRC7EA618

Page 1: ...das Innenaggregat beschrieben Verwenden Sie diese Anleitung zusammen mit der Bedienungsanleitung des Au enaggregats Nach dem Lesen der Anleitung legen Sie diese griffbereit zum Nachschlagen auf Nous v...

Page 2: ...or voordat u de airconditioner gebruikt Het omvat uitleg over het correcte gebruik van de unit en biedt hulp in geval een storing mocht optreden Gebruik deze handleding voor verdere raadpleging Obriga...

Page 3: ...5 7 DOWN FAN UP ON OFF M H L C hr hr TEST MODE TIMER RESERVE CANCEL DOWN UP TEST SWING FAN TIME TEMP ON OFF M H L C hr hr TEST 24 25 COOL HEAT CHANGEOVER REMOTE CONTROL SWITCH 21 20 19 18 23 22 00_CV_...

Page 4: ...uso del control remoto sin cables Lea tambi n el manual de instrucciones que viene con la unidad interior para un uso seguro del sistema y para su mantenimiento PRIMA DELL USO Il presente manuale d u...

Page 5: ...tact your dealer for instructions If you keep using the air conditioner under these conditions it will eventually break down and could cause electric shocks or catch fire Ask your dealer to install yo...

Page 6: ...set fan speed 7 DISPLAY INSPECTION TEST OPERATION When the INSPECTION TEST OPER ATION BUTTON is pressed the dis play shows the system mode is in 8 ON OFF BUTTON Press the button and the system will st...

Page 7: ...fil ter press the filter sign reset button on the remote controller The air filter clean ing time indicator lamp on the receiver will go out The Defrost Lamp will flash when the power is turned on Thi...

Page 8: ...CENTRALIZED CONTROL SYSTEM If the indoor unit is under centralized control it is necessary to switch the remote controller s setting In this case contact your DAIKIN dealer VRV System See the operati...

Page 9: ...er is automatically conducted FAN OPERATION DRY OPERATION 5 OPERATION PROCEDURE COOLING HEATING AUTOMATIC FAN AND PROGRAM DRY OPERATION 1 MODE The function of this program is to decrease the humidity...

Page 10: ...peed until the air conditioner reaches a certain temperature on the inside In this sit uation all you can do is wait If hot air accumulates on the ceiling and feet are left feeling cold it is recom me...

Page 11: ...ry cooling or programmed drying while the flaps are facing downward air flow direction may change unexpectedly There is nothing wrong with the equipment This serves to prevent dew formed on parts in t...

Page 12: ...CONTROLLER For VRV system MODE TIMER RESERVE CANCEL DOWN UP FAN TIME TEMP ON OFF C hr hr For Heat recovery system When one BS unit is connected with several indoor units Only the master remote control...

Page 13: ...ystem operates with the previously set air flow direction 1 MODE 2 MODE EMERGENCY OPERATION 1 2 1 STOP Press the EMERGENCY OPERA TION switch again This system provides two other control systems beside...

Page 14: ...against cold air being blown from the unit There is nothing wrong with the equipment I EMERGENCY STOP When the air conditioner stops in emergency the run lamp on the indoor unit starts blinking Take...

Page 15: ...re are batteries in the remote controller Place the batteries Check if the indoor unit number and wireless remote controller number are equal Operate the indoor unit with the remote con troller of the...

Page 16: ...Check the malfunction code A1 UF on the remote controller and contact the place of purchase See page 10 MODE TIMER RESERVE CANCEL DOWN UP TEST SWING FAN TIME TEMP ON OFF UNIT NO CODE Malfunction Code...

Page 17: ...0510 HT 3P107422 10F EM01A186B FS 00_CV_3P107422 10F_1 fm Page 2 Wednesday August 31 2005 1 42 PM...

Reviews: