EDUS721438
Installation Manual
BRC1E73
73
5.8
Procedure for Checking Error History
3P243521-7L
18
English
Remote controller display
Description
No display
Power outage, power voltage error or open-phase
Ɣ
Incorrect wiring (between indoor and outdoor units)
Ɣ
Indoor printed-circuit board assembly failure
Ɣ
Remote controller wiring not connected
Ɣ
Remote controller failure
Ɣ
Open fuse or tripped circuit breaker (outdoor unit)
Ɣ
Checking the connection.
Please stand by.
∗
Indoor printed-circuit board assembly failure
Ɣ
Wrong wiring (between indoor and outdoor units)
Ɣ
[
∗
Checking the connection. Please stand by.
] will be displayed for up to 90 seconds following the
application of power to the indoor unit. This is normal and does not indicate a malfunction.
Procedure for Checking Error History
8.
8-1
Press and hold
Cancel
button for
4 seconds or longer in the basic
screen. Service settings menu is
displayed.
Select
8-2
Error History
in the service
settings menu, and press
Menu/OK
button. The error history menu screen
is displayed.
Select
8-3
RC Error History
in the error
history menu, and press
Menu/OK
button.
Error codes and unit No. can be
confi rmed in the RC error history
screen.
In the error history, the 10 most recent
8-4
items are displayed in order of
occurrence.
Press
8-5
Cancel
button in the RC error
history screen 3 times.
The basic screen returns.
1
8-
<Basic screen>
<Service settings menu screen>
2
8-
Setting
Service Settings
Outdoor unit AirNet Address
Error History
Indoor Unit Status
Outdoor Unit Status
Forced Fan ON
Switch Main Sub Controller
2/3
Press
Menu/OK
button.
3
8-
Setting
Error History
RC Error History
Indoor unit Error History
2/2
Press
Menu/OK
button.
4
8-
5
8-
Setting
RC Error History
Unit
Error Date
Time
01 –– –– ––
/
––
/
–– ––:––
02 –– –– ––
/
––
/
–– ––:––
03 –– –– ––
/
––
/
–– ––:––
04 –– –– ––
/
––
/
–– ––:––
1/3
Unit No.
Latest record
01_EN_3P243521-7L.indd 18
11/27/2014 11:21:46 AM