Installation of the receiver in case of  

BRC082A41W

1  Remove the suction grille as described in the installation 

manual supplied with the decoration panel.

2  Detach the brand name plate part of the decoration panel 

piece, before attaching the decoration panel. 
This part is not needed hereafter.

3  Remove the electrical wiring box cover as described in the 

installation manual supplied with the indoor unit. (Be sure 
to turn off power, before removing the electrical wiring box 
cover.)

Push three hooks to 
detach them from the 
holes of the rear side.

Decoration 
panel

Brand name plate part

4  Pass the wire harness from the receiver through the wiring 

hole of the decoration panel. Then attach the receiver 
to the decoration panel. Lead the wire harness to the 
electrical wiring box on the indoor unit and connect it to 
X1A connector on the transmitter board.

Remove the screw and 
input the plastic band. 
Then screw it back.
The wire harness goes 
through the plastic band.

Clamp the wire harness 
from the receiver to other 
cables with the clamp.

Installation of the receiver in case of 

BRC082A42W/S

1  Remove the suction grille as described in the installation 

manual supplied with the decoration panel.

2  The receiver (1) should be installed in the corner that is 

surrounded by 2 square marks on one side and 1 square 
mark on the other, as shown in the illustration. Then 
remove the plastic corner cover.

1 square mark

2 square marks

3  Break off the plastic cover from back side of the panel.

01_EN_3P444567-1.indd   4

7/5/2016   11:05:29 AM

Summary of Contents for BRC082A41W

Page 1: ...añol WIRELESS REMOTE CONTROLLER KIT INSTALLATION MANUAL Installation manual Manuel dinstallation Manual de instalación MODELS BRC082A41W BRC082A42W BRC082A42S Manuel dinstallation 00_CV_3P444567 1 indd 1 5 11 2016 13 44 03 ...

Page 2: ...BRC082A42W 1 1 3 4 1 1 BRC082A42S 1 1 3 4 1 1 Figure 1 X24A X1A X2A 1 7 2 3 6 2 7 5 3 4 2 Figure 2 MODE TIMER RESERVE CANCEL DOWN UP TEST SWING FAN TIME TEMP ON OFF SETTING A B C 3 2 4 1 5 MODE TIMER RESERVE CANCEL DOWN UP TEST SWING FAN TIME TEMP ON OFF SETTING B D C A 3 2 4 5 1 6 Figure 3 Figure 4 00_CV_3P444567 1_H2 indd 1 6 29 2016 2 25 08 PM ...

Page 3: ...ow to operate the unit and how to perform maintenance Meaning of caution symbols Failure to observe these instructions properly may result in property damage or personal injury Information classified as NOTE contains instructions to ensure proper use of the equipment Refer also to the installation manual supplied with the indoor unit and the installation manual supplied with the decoration panel T...

Page 4: ...eceiver and the wireless remote controller If using both a wired remote controller and a wireless remote controller with one indoor unit change the MAIN SUB switch of the transmitter board Setting procedure Setting the transmitter board Set the wireless address switch SS2 on the transmitter board according to the table below Unit No 1 2 3 Wireless address switch SS2 1 2 3 1 2 3 1 2 3 When using bo...

Page 5: ...he indications on the wireless remote controller are turned off a discrepancy such as described above no longer occurs Affix the unit number label Affix corresponding unit number labels onto both air outlet of the decoration panel and onto back of the wireless remote controller NOTE Set the Unit No of the receiver and the wireless remote controller to be equal If the settings differ the signal fro...

Page 6: ...e decoration panel Then attach the receiver to the decoration panel Lead the wire harness to the electrical wiring box on the indoor unit and connect it to X1A connector on the transmitter board Remove the screw and input the plastic band Then screw it back The wire harness goes through the plastic band Clamp the wire harness from the receiver to other cables with the clamp Installation of the rec...

Page 7: ... setting If optional accessories are mounted on the indoor unit the indoor unit setting may have to be changed Refer to the instruction manual option handbook for each optional accessory See figure 4 A Mode No B Field Set mode C First code No D Second code No Procedure 1 When in normal mode hold down the button for at least 4 seconds to enter the Field Set mode 2 Select the desired Mode No with th...

Page 8: ...nged in function of ceiling height H 8 7 8ft 2 7m 8 7 8 H 9 13 16ft 2 7 H 3 0m 9 13 16 H 11 1 2ft 3 0 H 3 5m 1 Selection of air flow direction This setting is to be changed when blocking pad optional kit is used 4 way flow 3 way flow 2 way flow 4 Airflow direction range setting This setting is to be changed when range of swing flap movement needs to be changed Upper Medium Lower NOTE Factory setti...

Page 9: ...Two dimensional bar code is a manufacturing code 3P444567 1 M15B280 1607 HT 00_CV_3P444567 1 indd 2 5 11 2016 13 44 03 ...

Reviews: