Daikin BRC082A41W Installation Manual Download Page 4

2

English

Remote controller installation

Installing the wireless remote controller

 

„

Do not throw the remote controller or subject it to powerful 
shocks and do not store the remote controller where it may 
be exposed to moisture or direct sunlight.

 

„

When operating, point the transmitting part of the remote 
controller in the direction of the receiver.

 

„

The direct transmitting distance of the remote controller is 
approximately 23ft (7m).

 

„

The signal cannot be transmitted if something such as 
curtains blocks the receiver and the remote controller.

Installing to a wall or a pillar

1

Turn on all the fluorescent lamps in the room, if any, and 
find a location where the remote controller signals are 

properly received by the indoor unit (within 23ft (7m)).

Fix the remote controller 

holder with the supplied 
screws.

Remote 
controller 
holder

Push

2

Mount

1

Mount the remote 

controller on to the hook 
of the remote controller 
holder and then push it 
toward the wall.

How to insert the batteries

Slide the back cover to take 

it off.

Insert 2 dry batteries AAA.

LR03 (alkaline).

Position (+) and 
(–) correctly!

Replace the back cover.

Determination of address and MAIN/SUB 

remote controller

 

„

If setting multiple wireless remote controllers to operate in 
one room, perform address setting for the receiver and the 
wireless remote controller.

 

„

If using both a wired remote controller and a wireless 
remote controller with one indoor unit, change the MAIN/
SUB switch of the transmitter board.

Setting procedure

Setting the transmitter board

Set the wireless address switch (SS2) on the transmitter 
board according to the table below.

Unit No.

1

2

3

Wireless address switch
(SS2)

1    2    3

1    2    3

1    2    3

When using both a wired and a wireless remote controller 
for 1 indoor unit, the wired controller should be set to MAIN. 
Therefore, set the MAIN/SUB switch (SS1) of the transmitter 
board to SUB.

MAIN

SUB

MAIN/SUB switch (SS1)

MS

MS

Setting the address of the wireless remote controller

(See figure 3)

A  Field Set mode
B  Address (is factory set to “

”)

C  Display setting

Setting from the remote controller
1  Hold down the   button and the 

 button for at 

least 4 seconds to enter the Field Set mode. 

(Indicated in the display area in the figure.)

2  Press the 

 button and select an appropriate display 

setting (

A

/ ). Each time the button is pressed the display 

switches between “ 

” and “   ”. Refer to “Display setting 

A

/ ” on page 3 for full comprehension of this feature.

3  Press the   button and 

 button to set the address.

Address can be set from 1 to 6, but set it to 1-3 and to 
same address as the receiver. (The receiver does not 
work with address 4-6.)

4  Press the 

 button to confirm the setting.

5  Press the 

 button to quit the Field Set mode and 

to return to normal display again.

01_EN_3P444567-1.indd   2

7/5/2016   11:05:28 AM

Summary of Contents for BRC082A41W

Page 1: ...añol WIRELESS REMOTE CONTROLLER KIT INSTALLATION MANUAL Installation manual Manuel dinstallation Manual de instalación MODELS BRC082A41W BRC082A42W BRC082A42S Manuel dinstallation 00_CV_3P444567 1 indd 1 5 11 2016 13 44 03 ...

Page 2: ...BRC082A42W 1 1 3 4 1 1 BRC082A42S 1 1 3 4 1 1 Figure 1 X24A X1A X2A 1 7 2 3 6 2 7 5 3 4 2 Figure 2 MODE TIMER RESERVE CANCEL DOWN UP TEST SWING FAN TIME TEMP ON OFF SETTING A B C 3 2 4 1 5 MODE TIMER RESERVE CANCEL DOWN UP TEST SWING FAN TIME TEMP ON OFF SETTING B D C A 3 2 4 5 1 6 Figure 3 Figure 4 00_CV_3P444567 1_H2 indd 1 6 29 2016 2 25 08 PM ...

Page 3: ...ow to operate the unit and how to perform maintenance Meaning of caution symbols Failure to observe these instructions properly may result in property damage or personal injury Information classified as NOTE contains instructions to ensure proper use of the equipment Refer also to the installation manual supplied with the indoor unit and the installation manual supplied with the decoration panel T...

Page 4: ...eceiver and the wireless remote controller If using both a wired remote controller and a wireless remote controller with one indoor unit change the MAIN SUB switch of the transmitter board Setting procedure Setting the transmitter board Set the wireless address switch SS2 on the transmitter board according to the table below Unit No 1 2 3 Wireless address switch SS2 1 2 3 1 2 3 1 2 3 When using bo...

Page 5: ...he indications on the wireless remote controller are turned off a discrepancy such as described above no longer occurs Affix the unit number label Affix corresponding unit number labels onto both air outlet of the decoration panel and onto back of the wireless remote controller NOTE Set the Unit No of the receiver and the wireless remote controller to be equal If the settings differ the signal fro...

Page 6: ...e decoration panel Then attach the receiver to the decoration panel Lead the wire harness to the electrical wiring box on the indoor unit and connect it to X1A connector on the transmitter board Remove the screw and input the plastic band Then screw it back The wire harness goes through the plastic band Clamp the wire harness from the receiver to other cables with the clamp Installation of the rec...

Page 7: ... setting If optional accessories are mounted on the indoor unit the indoor unit setting may have to be changed Refer to the instruction manual option handbook for each optional accessory See figure 4 A Mode No B Field Set mode C First code No D Second code No Procedure 1 When in normal mode hold down the button for at least 4 seconds to enter the Field Set mode 2 Select the desired Mode No with th...

Page 8: ...nged in function of ceiling height H 8 7 8ft 2 7m 8 7 8 H 9 13 16ft 2 7 H 3 0m 9 13 16 H 11 1 2ft 3 0 H 3 5m 1 Selection of air flow direction This setting is to be changed when blocking pad optional kit is used 4 way flow 3 way flow 2 way flow 4 Airflow direction range setting This setting is to be changed when range of swing flap movement needs to be changed Upper Medium Lower NOTE Factory setti...

Page 9: ...Two dimensional bar code is a manufacturing code 3P444567 1 M15B280 1607 HT 00_CV_3P444567 1 indd 2 5 11 2016 13 44 03 ...

Reviews: