![background image](http://html.mh-extra.com/html/daikin/atxg25ev1b/atxg25ev1b_service-manual_501394037.webp)
Si04-858
Removal of PCB
Removal Procedure
35
2. Remove the signal
receiver PCB.
1
Release the hook with a
flat screwdriver.
2
Release the hook and
remove the receiver
unit.
3
Release the 2 hooks
and remove the signal
receiver PCB.
Step
Procedure
Points
INTELLIGENT EYE PCB
Signal
receiver
Buzzer
ON/OFF
switch
(R19143)
(R3888)
Hook
(R3889)
Hook
Hook
(R3890)