Installation manual

3

ATXF20~42C5V1B
Daikin room air conditioners
3P519299-11X – 2020.12

Table of contents

1 About the documentation

3

1.1

About this document..................................................................

3

2 Specific installer safety instructions

3

3 About the box

5

3.1

Indoor unit .................................................................................

5

3.1.1

To remove the accessories from the indoor unit.........

5

4 About the unit

5

4.1

System layout ............................................................................

5

4.2

Operation range ........................................................................

5

5 Unit installation

6

5.1

Preparing the installation site ....................................................

6

5.1.1

Installation site requirements of the indoor unit ..........

6

5.1.2

Additional installation site requirements of the
outdoor unit in cold climates .......................................

6

5.2

Opening the indoor unit .............................................................

6

5.2.1

To remove the front panel...........................................

6

5.2.2

To re-install the front panel .........................................

6

5.2.3

To remove the front grille ............................................

6

5.2.4

To re-install the front grille ..........................................

7

5.2.5

To remove the electrical wiring box cover...................

7

5.2.6

To open the service cover...........................................

7

5.3

Mounting the indoor unit............................................................

7

5.3.1

To install the mounting plate .......................................

7

5.3.2

To drill a wall hole .......................................................

7

5.3.3

To remove the pipe port cover ....................................

8

5.3.4

To provide drainage ....................................................

8

6 Piping installation

9

6.1

Preparing refrigerant piping .......................................................

9

6.1.1

Refrigerant piping requirements..................................

9

6.1.2

Refrigerant piping insulation .......................................

9

6.2

Connecting the refrigerant piping ..............................................

9

6.2.1

Guidelines when connecting the refrigerant piping .....

9

6.2.2

To connect the refrigerant piping to the indoor unit .... 10

6.3

Checking the refrigerant piping .................................................

10

6.3.1

To check for leaks....................................................... 10

6.3.2

To perform vacuum drying .......................................... 10

7 Electrical installation

10

7.1

Specifications of standard wiring components ..........................

11

7.2

To connect the electrical wiring to the indoor unit .....................

11

8 Finishing the indoor unit installation

11

8.1

To insulate the drain piping, refrigerant piping and
interconnection cable ................................................................

11

8.2

To pass the pipes through the wall hole....................................

11

8.3

To fix the unit on the mounting plate .........................................

12

9 Configuration

12

9.1

To set a different address..........................................................

12

10 Commissioning

13

10.1

Checklist before commissioning ................................................

13

10.2

To perform a test run .................................................................

13

10.2.1

To perform a test run in winter season ....................... 13

11 Disposal

13

12 Technical data

14

12.1

Wiring diagram ..........................................................................

14

12.1.1

Unified wiring diagram legend..................................... 14

1

About the documentation

1.1

About this document

Target audience

INFORMATION

This appliance is intended to be used by expert or trained
users  in  shops,  in  light  industry,  and  on  farms,  or  for
commercial and household use by lay persons.

WARNING

Make  sure  installation,  servicing,  maintenance,  repair  and
applied materials follow the instructions from Daikin and, in
addition,  comply  with  applicable  legislation  and  are
performed  by  qualified  persons  only.  In  Europe  and  areas
where  IEC  standards  apply,  EN/IEC  60335-2-40  is  the
applicable standard.

INFORMATION

This  document  only  describes  installation  instructions
specific  to  the  outdoor  unit.  For  installation  of  the  indoor
unit  (mounting  the  indoor  unit,  connecting  the  refrigerant
piping to the indoor unit, connecting the electrical wiring to
the indoor unit …), see the installation manual of the indoor
unit.

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety instructions that you MUST read before installing

▪ Format: Paper (in the box of the indoor unit)

Indoor unit installation manual:

▪ Installation instructions

▪ Format: Paper (in the box of the indoor unit)

Installer reference guide:

▪ Preparation of the installation, good practices, reference data,…

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.

The original documentation is written in English. All other languages
are translations.

2

Specific installer safety
instructions

Always observe the following safety instructions and regulations.

Unit installation (see 

"5 Unit installation"

 [

4

 6])

WARNING

Installation  shall  be  done  by  an  installer,  the  choice  of
materials  and  installation  shall  comply  with  the  applicable
legislation. In Europe, EN378 is the applicable standard.

Summary of Contents for ATXF20C5V1B

Page 1: ...Installation manual Daikin room air conditioners English Installation manual Daikin room air conditioners ATXF20C5V1B ATXF25C5V1B ATXF35C5V1B ATXF42C5V1B ...

Page 2: ...или други нормативни документи при условие че се използват съгласно нашите инструкции atitinka žemiau nurodytus standartus ir arba kitus norminius dokumentus su sąlyga kad yra naudojami pagal mūsų nurodymus tad ja lietoti atbilstoši ražotāja norādījumiem atbilst sekojošiem standartiem un citiem normatīviem dokumentiem sú v zhode s nasledovnou ými normou ami alebo iným i normatívnym i dokumentom am...

Page 3: ...ning 13 10 2 To perform a test run 13 10 2 1 To perform a test run in winter season 13 11 Disposal 13 12 Technical data 14 12 1 Wiring diagram 14 12 1 1 Unified wiring diagram legend 14 1 About the documentation 1 1 About this document Target audience INFORMATION This appliance is intended to be used by expert or trained users in shops in light industry and on farms or for commercial and household...

Page 4: ...rigerant gas leakage DANGER RISK OF EXPLOSION Do NOT start the unit if it is vacuumed Charging refrigerant see Charging refrigerant WARNING The refrigerant inside the unit is mildly flammable but normally does NOT leak If the refrigerant leaks in the room and comes in contact with fire from a burner a heater or a cooker this may result in fire or the formation of a harmful gas Turn off any combust...

Page 5: ...ff the power supply before servicing Install the switch box cover before turning on the power supply Commissioning see 10 Commissioning 413 DANGER RISK OF ELECTROCUTION DANGER RISK OF BURNING SCALDING CAUTION Do NOT perform the test operation while working on the indoor units When performing the test operation NOT only the outdoor unit but the connected indoor unit will operate as well Working on ...

Page 6: ...loor and keep the following requirements in mind for distances from the walls and the ceiling 50 50 30 mm 5 1 2 Additional installation site requirements of the outdoor unit in cold climates Protect the outdoor unit against direct snowfall and take care that the outdoor unit is NEVER snowed up In heavy snowfall areas it is very important to select an installation site where the snow will NOT affec...

Page 7: ...the centres of the drilling points on the wall using a tape measure Position the end of tape measure at symbol 4 Finish the installation by securing the mounting plate on the wall using M4 25L screws field supply INFORMATION The removed pipe port cover can be kept in the mounting plate pocket 337 770 A 285 44 5 170 48 48 44 5 116 5 1 17 337 50 213 237 170 A d e mm a a f h g a a b a c a c a d e A A...

Page 8: ... field supplied hose with inner Ø16 mm Do NOT forget to use a heat insulation tube on the indoor section of the extension hose a a b c Ø16 Ø16 a Drain hose supplied with the indoor unit b Heat insulation tube field supply c Extension drain hose Ridgid polyvinyl chloride pipe When connecting a ridgid polyvinyl chloride pipe nominal Ø13 mm directly to the drain hose as with embedded piping work use ...

Page 9: ...6 1 1 Refrigerant piping requirements NOTICE The piping and other pressure containing parts shall be suitable for refrigerant Use phosphoric acid deoxidised seamless copper for refrigerant Foreign materials inside pipes including oils for fabrication must be 30 mg 10 m Refrigerant piping diameter Use the same diameters as the connections on the outdoor units Class L1 liquid piping L1 gas piping 20...

Page 10: ... caps Soap water may contain salt which absorbs moisture that will freeze when the piping gets cold Soap water contains ammonia which may lead to corrosion of flared joints between the brass flare nut and the copper flare 1 Charge the system with nitrogen gas up to a gauge pressure of at least 200 kPa 2 bar It is recommended to pressurize to 3000 kPa 30 bar in order to detect small leaks 2 Check f...

Page 11: ...apart from each other Transmission wiring and power supply wiring may cross but may NOT run parallel In order to avoid any electrical interference the distance between both wirings should ALWAYS be at least 50 mm WARNING Provide adequate measures to prevent that the unit can be used as a shelter by small animals Small animals that make contact with electrical parts can cause malfunctions smoke or ...

Page 12: ...ing plate using 2 indoor unit fixing screws M4 12L accessory 9 Configuration 9 1 To set a different address In case 2 indoor units are installed in 1 room different addresses for 2 user interfaces can be set 1 Remove the batteries from the user interface 2 Cut the address jumper a a a Address jumper NOTICE Be careful NOT to damage any of the surrounding parts when cutting the address jumper 3 Turn...

Page 13: ...witch box The insulation resistance of the compressor is OK There are NO damaged components or squeezed pipes on the inside of the indoor and outdoor units There are NO refrigerant leaks The correct pipe size is installed and the pipes are properly insulated The stop valves gas and liquid on the outdoor unit are fully open 10 2 To perform a test run Prerequisite Power supply MUST be in the specifi...

Page 14: ...r D V D Diode DB Diode bridge DS DIP switch E H Heater FU F U for characteristics refer to PCB inside your unit Fuse FG Connector frame ground H Harness H P LED V L Pilot lamp light emitting diode Symbol Meaning HAP Light emitting diode service monitor green HIGH VOLTAGE High voltage IES Intelligent eye sensor IPM Intelligent power module K R KCR KFR KHuR K M Magnetic relay L Live L Coil L R React...

Page 15: ...ion manual 15 ATXF20 42C5V1B Daikin room air conditioners 3P519299 11X 2020 12 Symbol Meaning X M Terminal strip block Y E Electronic expansion valve coil Y R Y S Reversing solenoid valve coil Z C Ferrite core ZF Z F Noise filter ...

Page 16: ...TANBUL TÜRKİYE Tel 0216 453 27 00 Faks 0216 671 06 00 Çağrı Merkezi 444 999 0 Web www daikin com tr Gülsuyu Mahallesi Fevzi Çakmak Caddesi Burçak Sokak No 20 34848 Maltepe 3P519299 11X 2020 12 Copyright 2020 Daikin Verantwortung für Energie und Umwelt ...

Reviews: