6 Energy saving and optimum operation

Operation manual

9

ATXF20~42C5V1B
Daikin room air conditioner
3P520336-10K – 2020.08

5.3.6

Econo operation

This  is  a  function  which  enables  efficient  operation  by  limiting  the
maximum power consumption value. This function is useful for cases
in which attention should be paid to ensure a circuit breaker will not
trip when the product runs alongside other appliances.

INFORMATION

▪ Powerful and Econo operation CANNOT be used at the

same time. The last selected function takes priority.

▪ Econo  operation  reduces  power  consumption  of  the

outdoor  unit  by  limiting  the  rotation  speed  of  the
compressor.  If  power  consumption  is  already  low,
Econo  operation  will  NOT  further  reduce  power
consumption.

To start/stop Econo operation

1

Press 

 to start.

Result: 

 is displayed on the LCD.

2

Press 

 to stop.

Result: 

 disappears from the LCD.

5.3.7

OFF/ON timer operation

Timer  functions  are  useful  for  automatically  switching  the  air
conditioner off/on at night or in the morning. You can also use OFF
timer and ON timer in combination.

INFORMATION

Program the timer again in case of:

▪ A breaker has turned the unit off.

▪ A power failure.

▪ After replacing batteries in the user interface.

To start/stop ON timer operation

1

Press 

 to start.

Result: 

 is displayed on the LCD and the timer lamp lights

up.

INFORMATION

Each time 

 is pressed, the time setting advances by

1 hour. The timer can be set between 1 to 12 hours.

2

Press 

 to stop.

Result: 

  disappears  from  the  LCD  and  the  timer  lamp

goes off.

To start/stop OFF timer operation

1

Press 

 to start.

Result: 

 is displayed on the LCD and the timer lamp lights

up.

INFORMATION

Each time 

 is pressed, the time setting advances by

1 hour. The timer can be set between 1 to 9 hours.

2

Press 

 to stop.

Result: 

  disappears  from  the  LCD  and  the  timer  lamp

goes off.

INFORMATION

When you set the ON/OFF timer, the time setting is stored
in  the  memory.  The  memory  will  be  reset  when  the  user
interface batteries are replaced.

Use of night set mode in combination with OFF timer

The  air  conditioner  automatically  adjusts  the  temperature
setting  (0.5°C  up  in  cooling,  2.0°C  down  in  heating)  to
prevent 

excessive 

cooling/heating 

and 

ensure 

a

comfortable sleeping temperature.

To combine OFF timer and ON timer

1

To  set  the  timers,  refer  to 

"To  start/stop  OFF  timer

operation" 

[

4

 9] and 

"To start/stop ON timer operation" 

[

4

 9].

Result: 

 and 

 are displayed on the LCD.

2

Example of what is displayed on the LCD if you combine the 2

timers: 

6

Energy saving and optimum
operation

INFORMATION

▪ Even if the unit is turned OFF, it consumes electricity.

▪ When the power turns back on after a power break, the

previously selected mode will be resumed.

CAUTION

NEVER  expose  little  children,  plants  or  animals  directly  to
the airflow.

WARNING

Do NOT place objects below the indoor and/or outdoor unit
that  may  get  wet.  Otherwise  condensation  on  the  unit  or
refrigerant pipes, air filter dirt or drain blockage may cause
dripping,  and  objects  under  the  unit  may  get  dirty  or
damaged.

WARNING

Do  NOT  place  a  flammable  spray  bottle  near  the  air
conditioner and do NOT use sprays near the unit. Doing so
may result in a fire.

CAUTION

Do  NOT  operate  the  system  when  using  a  room
fumigation-type  insecticide.  Chemicals  could  collect  in  the
unit,  and  endanger  the  health  of  people  who  are
hypersensitive to chemicals.

▪ Make  sure  the  area  is  well  ventilated.  Do  NOT  block  any

ventilation openings.

▪ Turn the breaker off when the unit is NOT used for longer periods

of time. If the breaker is on, the unit consumes electricity. Before
restarting the unit, turn the breaker on 6 hours before operation to
ensure smooth running.

▪ Adjust the air flow direction to avoid cool air from gathering on the

floor  or  warm  air  against  the  ceiling.  (Up  during  cooling  or  dry
operation to the ceiling and down during heating operation.)

▪ Avoid direct air flow to room inhabitants.

▪ Operate  the  system  within  the  recommended  temperature  range

(26~28°C for cooling and 20~24°C for heating) to save energy.

Summary of Contents for ATXF20C5V1B

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner ATXF20C5V1B ATXF25C5V1B ATXF35C5V1B ATXF42C5V1B ...

Page 2: ...es while the air conditioner is not in operation 12 8 2 Solving problems based on error codes 12 9 Disposal 13 1 About the documentation 1 1 About this document Thank you for purchasing this product Please Read the documentation carefully before operating the user interface to ensure the best possible performance Request the installer to inform you about the settings that he used to configure your...

Page 3: ...al symbols are Pb lead 0 004 Waste batteries must be treated at a specialized treatment facility for reuse By ensuring waste batteries are disposed of correctly you will help to prevent potential negative consequences for the environment and human health 2 2 Instructions for safe operation WARNING MILDLY FLAMMABLE MATERIAL The refrigerant inside this unit is mildly flammable CAUTION Do NOT insert ...

Page 4: ...therwise an electric shock and injury may result WARNING Stop operation and shut off the power if anything unusual occurs burning smells etc Leaving the unit running under such circumstances may cause breakage electric shock or fire Contact your dealer CAUTION This unit is equipped with electrically powered safety measures such as a refrigerant leak detector In order to be effective the unit must ...

Page 5: ...sabled if fluorescent lamps are in the room In that case contact your installer Other appliances If the user interface signals operate other appliances move the other appliances or contact your installer Curtains Make sure that the signal between the unit and the user interface is NOT blocked by curtains or other objects NOTICE Do NOT drop the user interface Do NOT let the user interface get wet 3...

Page 6: ...out 1 year 1 Remove the back cover 2 Insert both batteries at once 3 Put the cover back 2 3 1 AAA LR03 4 3 To turn on the power supply 1 Turn the circuit breaker on Result The flap of the indoor unit will open and close to set the reference position 5 Operation 5 1 Operation range Operation mode Operation range Cooling a b Outdoor temperature 10 46 C DB Indoor temperature 18 32 C DB Indoor humidit...

Page 7: ...he system s cooling or heating effect decreases when the outside temperature is too high or too low Defrost operation During heating operation frost might occur on the outdoor unit and decrease the heating capacity In that case the system automatically switches to defrosting operation to remove the frost During defrosting operation hot air is NOT blown from the indoor unit 5 3 1 To start stop oper...

Page 8: ...the air 5 3 4 Comfort airflow operation This operation can be used in heating or cooling operation mode It will provide a comfortable wind that will NOT come in direct contact with people The system automatically sets the fixed airflow position upward in Cooling and downward in Heating operation mode Cooling operation mode Heating operation mode INFORMATION Powerful and Comfort airflow operation C...

Page 9: ...ory The memory will be reset when the user interface batteries are replaced Use of night set mode in combination with OFF timer The air conditioner automatically adjusts the temperature setting 0 5 C up in cooling 2 0 C down in heating to prevent excessive cooling heating and ensure a comfortable sleeping temperature To combine OFF timer and ON timer 1 To set the timers refer to To start stop OFF ...

Page 10: ...ioner or air filter be sure to stop operation and turn all power supplies off Otherwise an electric shock and injury may result WARNING To prevent electrical shocks or fire Do NOT rinse the unit Do NOT operate the unit with wet hands Do NOT place any objects containing water on the unit CAUTION After a long use check the unit stand and fitting for damage If damaged the unit may fall and result in ...

Page 11: ...ms into account before a long idle period Operate the unit in fan only mode for several hours to dry the inside of the unit 1 Press and select fan only operation 2 Press to start operation 3 After operation stops turn the breaker off 4 Clean the air filters and replace them in their original position 5 Remove the batteries from the user interface INFORMATION It is recommended to have periodical ma...

Page 12: ...his sound is generated when the refrigerant control valves or electrical parts operate 8 1 6 Symptom A clapping sound is heard This sound is generated when an external device sucks air out of the room e g exhaust fan extractor hood while the doors and windows in the room are closed Open the doors or windows or turn off the device 8 1 7 Symptom The outdoor fan rotates while the air conditioner is n...

Page 13: ...rmistor abnormality Discharge pipe thermistor abnormality Outdoor heat exchanger thermistor abnormality Electrical parts heat error Radiation fin temperature rise Inverter instantaneous overcurrent DC Radiation fin thermistor abnormality Compressor internal temperature error 9 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and...

Page 14: ......

Page 15: ......

Page 16: ...TANBUL TÜRKİYE Tel 0216 453 27 00 Faks 0216 671 06 00 Çağrı Merkezi 444 999 0 Web www daikin com tr Gülsuyu Mahallesi Fevzi Çakmak Caddesi Burçak Sokak No 20 34848 Maltepe 3P520336 10K 2020 08 Copyright 2020 Daikin Verantwortung für Energie und Umwelt ...

Reviews: