background image

5 Operation

Operation manual

7

ATXF20~42C5V1B
Daikin room air conditioner
3P520336-10K – 2020.08

Feature

Tasks

 Airflow rate

To adjust the amount of air blown into
the room.

To run more quietly.

Advanced features

 Econo

To use the system when you are also
using other power-consuming
appliances.

To save energy.

 Comfort

To provide a comfortable airflow that
does NOT come in direct contact with
people.

 Powerful

To cool down or heat up the room
quickly.

 ON timer + 

 OFF

timer

To automatically turn ON or OFF the
system.

5.3

Operation mode and temperature
setpoint

When.

  Adjust  the  system  operation  mode  and  set  the  temperature

when you want to:

▪ Heat up or cool down a room

▪ Blow air in a room without heating or cooling

▪ Decrease the humidity in a room

What.

  The  system  operates  differently,  depending  on  the  user

selection.

Setting

Description

 Automatic

The system cools down or heats up a
room to the temperature setpoint. It
automatically switches between cooling
and heating if necessary.

 Drying

The system decreases the humidity in a
room.

 Heating

The system heats up a room to the
temperature setpoint.

 Cooling

The system cools down a room to the
temperature setpoint.

 Fan

The system only controls the airflow
(airflow rate and airflow direction).

The system does NOT control the
temperature.

Additional info:

Outside  temperature.

  The  system's  cooling  or  heating  effect

decreases when the outside temperature is too high or too low.

Defrost operation.

 During heating operation, frost might occur on

the  outdoor  unit  and  decrease  the  heating  capacity.  In  that  case,
the  system  automatically  switches  to  defrosting  operation  to
remove  the  frost.  During  defrosting  operation,  hot  air  is  NOT
blown from the indoor unit.

5.3.1

To start/stop operation mode and to set
the temperature

: Unit is operating.

: Operation mode = Automatic

: Operation mode = Drying

: Operation mode = Heating

: Operation mode = Cooling

: Operation mode = Fan only

: Shows the set temperature.

1

Press 

 one or more times to select the operation mode.

Result: 

The mode will be set in the following sequence:

2

Press 

 to 

start

 operation.

Result: 

 is displayed on the LCD.

Result: 

The operation lamp lights up.

3

Press   or   on the 

 button one or more times to lower or

raise the 

temperature

.

Note:

  When  using  drying  or  fan  only  mode,  you  cannot  adjust  the

temperature.

4

Press 

 to 

stop

 operation.

Result: 

 disappears from the LCD.

Result: 

The operation lamp goes off.

5.3.2

Airflow rate

1

Press 

 to choose:

5 airflow rate levels, from "

" to "

"

Automatic airflow rate operation

Indoor unit quiet operation. When the airflow rate is

set to "

", the noise from the unit will be reduced.

INFORMATION

▪ If  the  unit  reaches  the  temperature  setpoint  in  cooling

or heating mode, the fan will stop operating.

▪ When  using  drying  operation  mode,  you  CANNOT

adjust the airflow rate setting.

To adjust the airflow rate

1

Press 

 to change the airflow setting as follows:

Summary of Contents for ATXF20C5V1B

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner ATXF20C5V1B ATXF25C5V1B ATXF35C5V1B ATXF42C5V1B ...

Page 2: ...es while the air conditioner is not in operation 12 8 2 Solving problems based on error codes 12 9 Disposal 13 1 About the documentation 1 1 About this document Thank you for purchasing this product Please Read the documentation carefully before operating the user interface to ensure the best possible performance Request the installer to inform you about the settings that he used to configure your...

Page 3: ...al symbols are Pb lead 0 004 Waste batteries must be treated at a specialized treatment facility for reuse By ensuring waste batteries are disposed of correctly you will help to prevent potential negative consequences for the environment and human health 2 2 Instructions for safe operation WARNING MILDLY FLAMMABLE MATERIAL The refrigerant inside this unit is mildly flammable CAUTION Do NOT insert ...

Page 4: ...therwise an electric shock and injury may result WARNING Stop operation and shut off the power if anything unusual occurs burning smells etc Leaving the unit running under such circumstances may cause breakage electric shock or fire Contact your dealer CAUTION This unit is equipped with electrically powered safety measures such as a refrigerant leak detector In order to be effective the unit must ...

Page 5: ...sabled if fluorescent lamps are in the room In that case contact your installer Other appliances If the user interface signals operate other appliances move the other appliances or contact your installer Curtains Make sure that the signal between the unit and the user interface is NOT blocked by curtains or other objects NOTICE Do NOT drop the user interface Do NOT let the user interface get wet 3...

Page 6: ...out 1 year 1 Remove the back cover 2 Insert both batteries at once 3 Put the cover back 2 3 1 AAA LR03 4 3 To turn on the power supply 1 Turn the circuit breaker on Result The flap of the indoor unit will open and close to set the reference position 5 Operation 5 1 Operation range Operation mode Operation range Cooling a b Outdoor temperature 10 46 C DB Indoor temperature 18 32 C DB Indoor humidit...

Page 7: ...he system s cooling or heating effect decreases when the outside temperature is too high or too low Defrost operation During heating operation frost might occur on the outdoor unit and decrease the heating capacity In that case the system automatically switches to defrosting operation to remove the frost During defrosting operation hot air is NOT blown from the indoor unit 5 3 1 To start stop oper...

Page 8: ...the air 5 3 4 Comfort airflow operation This operation can be used in heating or cooling operation mode It will provide a comfortable wind that will NOT come in direct contact with people The system automatically sets the fixed airflow position upward in Cooling and downward in Heating operation mode Cooling operation mode Heating operation mode INFORMATION Powerful and Comfort airflow operation C...

Page 9: ...ory The memory will be reset when the user interface batteries are replaced Use of night set mode in combination with OFF timer The air conditioner automatically adjusts the temperature setting 0 5 C up in cooling 2 0 C down in heating to prevent excessive cooling heating and ensure a comfortable sleeping temperature To combine OFF timer and ON timer 1 To set the timers refer to To start stop OFF ...

Page 10: ...ioner or air filter be sure to stop operation and turn all power supplies off Otherwise an electric shock and injury may result WARNING To prevent electrical shocks or fire Do NOT rinse the unit Do NOT operate the unit with wet hands Do NOT place any objects containing water on the unit CAUTION After a long use check the unit stand and fitting for damage If damaged the unit may fall and result in ...

Page 11: ...ms into account before a long idle period Operate the unit in fan only mode for several hours to dry the inside of the unit 1 Press and select fan only operation 2 Press to start operation 3 After operation stops turn the breaker off 4 Clean the air filters and replace them in their original position 5 Remove the batteries from the user interface INFORMATION It is recommended to have periodical ma...

Page 12: ...his sound is generated when the refrigerant control valves or electrical parts operate 8 1 6 Symptom A clapping sound is heard This sound is generated when an external device sucks air out of the room e g exhaust fan extractor hood while the doors and windows in the room are closed Open the doors or windows or turn off the device 8 1 7 Symptom The outdoor fan rotates while the air conditioner is n...

Page 13: ...rmistor abnormality Discharge pipe thermistor abnormality Outdoor heat exchanger thermistor abnormality Electrical parts heat error Radiation fin temperature rise Inverter instantaneous overcurrent DC Radiation fin thermistor abnormality Compressor internal temperature error 9 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and...

Page 14: ......

Page 15: ......

Page 16: ...TANBUL TÜRKİYE Tel 0216 453 27 00 Faks 0216 671 06 00 Çağrı Merkezi 444 999 0 Web www daikin com tr Gülsuyu Mahallesi Fevzi Çakmak Caddesi Burçak Sokak No 20 34848 Maltepe 3P520336 10K 2020 08 Copyright 2020 Daikin Verantwortung für Energie und Umwelt ...

Reviews: