3/8
Breadcrumb
Field code
Setting name
Range, step
Default value
Date
Value
User settings
└─
Preset values
└─
Room temperature
7.4.1.1
R/W
[3-07]~[3-06], step: A.3.2.4
21°C
7.4.1.2
R/W
[3-07]~[3-06], step: A.3.2.4
19°C
└─
LWT main
7.4.2.1
[8-09]
R/W
[9-01]~[9-00], step: 1°C
35°C
7.4.2.2
[8-0A]
R/W
[9-01]~[9-00], step: 1°C
33°C
7.4.2.5
R/W
-10~10°C, step: 1°C
0°C
7.4.2.6
R/W
-10~10°C, step: 1°C
-2°C
└─
Tank temperature
7.4.3.1
[6-0A]
R/W
30~[6-0E]°C, step: 1°C
60°C
7.4.3.2
[6-0B]
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
7.4.3.3
[6-0C]
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
└─
Quiet level
7.4.4
R/W
0: Level 1
1: Level 2
2: Level 3
└─
Electricity price
7.4.5.1
[C-0C]
[D-0C]
R/W
0,00~990/kWh
0/kWh
7.4.5.2
[C-0D]
[D-0D]
R/W
0,00~990/kWh
0/kWh
7.4.5.3
[C-0E]
[D-0E]
R/W
0,00~990/kWh
0/kWh
└─
Fuel price
7.4.6
R/W
0,00~990/kWh
0,00~290/MBtu
8,0/kWh
└─
Set weather dependent
└─
Main
└──────────────────
Set weather-dependent heating
7.7.1.1
[1-00]
Set weather-dependent heating
Low ambient temp. for LWT main zone heating
WD curve.
R/W
-40~5°C, step: 1°C
-10°C
7.7.1.1
[1-01]
Set weather-dependent heating
High ambient temp. for LWT main zone heating
WD curve.
R/W
10~25°C, step: 1°C
15°C
7.7.1.1
[1-02]
Set weather-dependent heating
Leaving water value for low ambient temp. for
LWT main zone heating WD curve.
R/W
[9-01]~[9-00]°C, step: 1°C
35°C
7.7.1.1
[1-03]
Set weather-dependent heating
Leaving water value for high ambient temp. for
LWT main zone heating WD curve.
R/W
[9-01]~min(45, [9-00])°C , step: 1°C
25°C
└─
Additional
└──────────────────
Set weather-dependent heating
7.7.2.1
[0-00]
Set weather-dependent heating
Leaving water value for high ambient temp. for
LWT add zone heating WD curve.
R/W
[9-05]~min(45,[9-06])°C, step: 1°C
35°C
7.7.2.1
[0-01]
Set weather-dependent heating
Leaving water value for low ambient temp. for
LWT add zone heating WD curve.
R/W
[9-05]~[9-06]°C, step: 1°C
45°C
7.7.2.1
[0-02]
Set weather-dependent heating
High ambient temp. for LWT add zone heating
WD curve.
R/W
10~25°C, step: 1°C
15°C
7.7.2.1
[0-03]
Set weather-dependent heating
Low ambient temp. for LWT add zone heating
WD curve.
R/W
-40~5°C, step: 1°C
-10°C
Installer settings
└─
System layout
└─
Standard
A.2.1.1
[E-00]
R/O
0~5
0: LT split
A.2.1.2
[E-01]
R/O
0: 8 (*5)
1: 16 (*6)
A.2.1.3
[E-02]
R/O
1: Type 2
A.2.1.4
[E-03]
R/O
1: 1 step
A.2.1.5
[5-0D]
R/O
1: 1P,(1/1+2)
A.2.1.6
[D-01]
R/W
0: No
1: Active open
2: Active closed
A.2.1.7
[C-07]
R/W
0: LWT control
1: Ext RT control
2: RT control
A.2.1.8
[7-02]
R/W
0: 1 LWT zone
1: 2 LWT zones
A.2.1.9
[F-0D]
R/W
0: Continuous
1: Sample
2: Request
A.2.1.A
[E-04]
R/O
0: No (*6)
1: Yes (*5)
A.2.1.B
R/W
0: At unit
1: In room
└─
Options
A.2.2.1
[E-05]
R/W
0: No
1: Yes
A.2.2.3
[E-07]
R/O
0~6
1: Type 2
A.2.2.4
[C-05]
R/W
1: Thermo ON/OFF
2: C/H request
A.2.2.5
[C-06]
R/W
1: Thermo ON/OFF
2: C/H request
A.2.2.6.1
[C-02]
Digital I/O PCB
Ext. backup heat src
R/W
0~3
0: No
1: Bivalent
A.2.2.6.2
[D-07]
Digital I/O PCB
Solar kit
R/O
0~1
0: No
A.2.2.6.3
[C-09]
Digital I/O PCB
Alarm output
R/W
0: Normally open
1: Normally closed
A.2.2.6.4
[F-04]
Digital I/O PCB
Bottom plate heater
R/W
0: No
1: Yes
A.2.2.7
[D-04]
R/W
0: No
1: Pwr consmp ctrl
Field settings table
Installer setting at variance with
default value
Comfort (heating)
Eco (heating)
Storage comfort
Storage eco
Comfort (heating)
Eco (heating)
Comfort (heating)
Eco (heating)
High
Medium
Low
Reheat
Unit type
Compressor type
Indoor software type
Backup heater steps
BUH type
Preferential kWh rate
Unit control method
Number of LWT zones
Pump operation mode
Power saving possible
User interface location
DHW operation
DHW tank type
Contact type main
Contact type add.
Demand PCB
(*5) *04/08*
(*6) *16*
4P401673-1 - 2015.04