4 Installation
Installation manual
7
EPGA11~16DAV3
Daikin Altherma – Low temperature split
4P556065-1 – 2018.10
≥150
620
350
(345-355)
a
(mm)
261.5
6× M12
a
Make sure not to cover the drain holes.
In any case, make sure the unit is positioned at least 100 mm above
the maximum expected level of snow.
4.2.2
To install the outdoor unit
6× M12
4.2.3
To provide drainage
Make sure that condensate can be evacuated properly. When the
unit is in cooling mode, condensate may also form in the hydro part.
When providing drainage, therefore make sure to cover the entire
unit.
NOTICE
If the unit is installed in a cold climate, take adequate
measures so that the evacuated condensate CANNOT
freeze.
Drain holes (dimensions in mm)
160
620
261.5
119
161
260
285
279
345
595
416
262
38
71
C
D
E
D
D
D
D
A
B
A
Discharge side
B
Distance between anchor points
C
Bottom frame
D
Drain holes
E
Knockout hole for snow
NOTICE
If drain holes of the outdoor unit are covered by a mounting
base or by floor surface, raise the unit to provide a free
space of more than 150 mm under the outdoor unit.
≥150 mm
4.2.4
To fix the fluorinated greenhouse gases
label
1
Fill in the label as follows:
RXXX
d
Contains fluorinated greenhouse gases
kg
tCO
2
eq
GWP × kg
1000
=
GWP: XXX
a
b
c
a
If a multilingual fluorinated greenhouse gases label is
delivered with the unit (see accessories), peel off the
applicable language and stick it on top of
a
.
b
Total refrigerant charge
c
Greenhouse gas emissions
of the total refrigerant charge
expressed as tonnes CO
2
equivalent
d
GWP = Global warming potential
NOTICE
In Europe, the
greenhouse gas emissions
of the total
refrigerant charge in the system (expressed as tonnes CO
2
equivalent) is used to determine the maintenance intervals.
Follow the applicable legislation.
Formula to calculate the greenhouse gas emissions:
GWP value of the refrigerant × Total refrigerant charge [in
kg] / 1000
2
Fix the label on the inside of the outdoor unit near the gas and
liquid stop valves.
4.2.5
To prevent the outdoor unit from falling
over
In case the unit is installed in places where strong wind can tilt the
unit, take following measure:
1
Prepare 2 cables as indicated in the following illustration (field
supply).
2
Place the 2 cables over the outdoor unit.
3
Insert a rubber sheet between the cables and the outdoor unit
to prevent the cables from scratching the paint (field supply).
4
Attach the ends of the cables and tighten them.