14 Technical data
Installation and operation manual
41
EHYKOMB33A
Daikin Altherma hybrid heat pump – gas boiler module
4P353067-1K – 2020.10
Country
Country code
(EN 437)
Gas category
Default setting
After conversion to
G25
After conversion to
G31
Czech Republic
CZ
II
2H3P
G20 (20 mbar)
—
G31 (37 mbar)
Germany
DE
II
2ELL3P
G20 (20 mbar)
G25 (20 mbar)
G31 (50 mbar)
Denmark
DK
I
2H
G20 (20 mbar)
—
—
Spain
ES
II
2H3P
G20 (20 mbar)
—
G31 (37 mbar)
France
FR
II
2Esi3P
G20/G25 (20/25 mbar)
—
G31 (37 mbar)
United Kingdom
GB
II
2H3P
G20 (20 mbar)
—
G31 (37 mbar)
Greece
GR
II
2H3P
G20 (20 mbar)
—
G31 (37 mbar)
Croatia
HR
II
2H3P
G20 (20 mbar)
—
G31 (37 mbar)
Hungary
HU
I
2H
G20 (25 mbar)
—
—
Ireland
IE
II
2H3P
G20 (20 mbar)
—
G31 (37 mbar)
Italy
IT
II
2H3P
G20 (20 mbar)
—
G31 (37 mbar)
Lithuania
LT
II
2H3P
G20 (20 mbar)
—
G31 (37 mbar)
Latvia
LV
I
2H
G20 (20 mbar)
—
—
Malta
MT
I
3P
—
—
G31 (30 mbar)
Poland
PL
II
2E3P
G20 (20 mbar)
—
G31 (37 mbar)
Portugal
PT
II
2H3P
G20 (20 mbar)
—
G31 (37 mbar)
Slovenia
SI
II
2H3P
G20 (20 mbar)
—
G31 (37 mbar)
Slovakia
SK
II
2H3P
G20 (20 mbar)
—
G31 (37 mbar,
50 mbar)
Romania
RO
II
2H3P
G20 (20 mbar)
—
G31 (30 mbar)
Turkey
TR
I
2H
G20 (20 mbar)
—
—
Ukraine
UA
II
2H
G20 (20 mbar)
—
—