4 Energy saving tips
Operation manual
8
EHBH04~16CBV + EHVH04~16S18+26CBV
Daikin Altherma – Low temperature split
4P449973-1 – 2016.06
INFORMATION
Anti-legionella heater.
In the menu structure the term
"Booster heater" is used. However, this is actually an anti-
legionella heater.
3.8
Installer settings: Tables to be
filled in by installer
3.8.1
Quick wizard
Setting
Default
Fill in…
Backup heater configuration (only for unified backup heater)
[A.2.1.5]
Backup heater steps
0
BUH type
0 (1P,(1/2))
Forced off contact [A.2.1.6]
Forced off contact
0 (No)
Space heating settings [A.2.1]
Unit control method
0 (LWT control)
User interface location
1 (In room)
Number of LWT zones
1 (1 LWT zone)
Pump operation mode
1 (Sample)
Domestic hot water settings [A.2.2]
DHW operation
Depends on
model
DHW tank type
Depends on
model
DHW pump
0 (No)
Thermostats [A.2.2]
Contact type main
2 (Thermo ON/
OFF)
Contact type add.
2 (Thermo ON/
OFF)
External sensor
0 (No)
Digital I/O PCB [A.2.2.6]
Ext. backup heat src
0 (No)
Solar kit
0 (No)
Alarm output
0 (Normally open)
Bottom plate heater
0 (No)
Demand PCB [A.2.2.7]
Demand PCB
0 (No)
Energy metering [A.2.2]
External kWh meter 1
0 (No)
External kWh meter 2
0 (No)
Capacities (energy metering) [A.2.3]
Anti-legionella heater
Depends on
model
BUH: step 1
3 kW
BUH: step 2
3 kW
Bottom plate heater
0 W
3.8.2
Space heating control
Setting
Default
Fill in…
Leaving water temperature: Main zone [A.3.1.1]
LWT setpoint mode
1 (WD)
Leaving water temperature: Additional zone [A.3.1.2]
LWT setpoint mode
1 (WD)
Setting
Default
Fill in…
Leaving water temperature: Delta T source [A.3.1.3]
Heating
5°C
Leaving water temperature: Modulation [A.3.1.1.5]
Modulated LWT
0 (No)
Leaving water temperature: Emitter type [A.3.1.1.7]
Emitter type
1 (Slow)
3.8.3
Domestic hot water control [A.4]
Setting
Default
Fill in…
Type
2 (Scheduled
only)
Maximum setpoint
Depends on
model
INFORMATION
There is a risk of space heating capacity shortage/comfort
problem (in case of frequent domestic hot water operation,
frequent and long space heating interruption will happen)
when selecting [6‑0D]=0 ([A.4.1] Domestic hot water
Type=Reheat only).
INFORMATION
When the DHW tank booster mode is active, the risk of
space heating and capacity shortage comfort problems is
significant. In case of frequent domestic hot water
operation, frequent and long space heating interruptions
will happen.
3.8.4
Contact/helpdesk number [6.3.2]
Setting
Default
Fill in…
Contact/helpdesk number
—
4
Energy saving tips
Tips about room temperature
▪ Make sure the desired room temperature is NEVER too high, but
ALWAYS according to your actual needs. Each saved degree can
save up to 6% of heating costs.
▪ Do NOT increase the desired room temperature to speed up
space heating. The space will NOT heat up faster.
▪ When your system layout contains slow heat emitters (example:
under floor heating), avoid large fluctuation of the desired room
temperature and do NOT let the room temperature drop too low. It
will take more time and energy to heat up the room again.
▪ Use a weekly schedule for your normal space heating needs. If
necessary, you can easily deviate from the schedule:
▪ For shorter periods: You can overrule the scheduled room
temperature.
Example:
When you have a party, or when you
are leaving for a couple of hours.
▪ For longer periods: You can use the holiday mode.
Example:
When you stay at home during your holiday, or when you go
away during your holiday.