5 Maintenance and service

Operation manual

9

EHBH04~16CBV + EHVH04~16S18+26CBV
Daikin Altherma – Low temperature split
4P449973-1 – 2016.06

Tips about DHW tank temperature

▪ Use a weekly schedule for your normal domestic hot water needs

(only in scheduled mode).

▪ Program  to  heat  up  the  DHW  tank  to  a  preset  value  (Storage

comfort  =  higher  DHW  tank  temperature)  during  the  night,
because then space heating demand is lower.

▪ If  heating  up  the  DHW  tank  once  at  night  is  not  sufficient,

program to additionally heat up the DHW tank to a preset value
(Storage eco = lower DHW tank temperature) during the day.

▪ Make  sure  the  desired  DHW  tank  temperature  is  NOT  too  high.

Example: 

After installation, lower the DHW tank temperature daily

by 1°C and check if you still have enough hot water.

▪ Program  to  turn  ON  the  domestic  hot  water  pump  only  during

periods of the day when instant hot water is necessary. 

Example:

In the morning and evening.

5

Maintenance and service

5.1

Overview: Maintenance and
service

The installer has to perform a yearly maintenance. You can find the
contact/helpdesk number via the user interface.

As end user, you have to:

▪ Keep the area around the unit clean.

▪ Keep the user interface clean with a soft damp cloth. Do NOT use

any detergents.

▪ Regularly check if the water pressure indicated on the manometer

is above 1 bar.

Refrigerant

This  product  contains  fluorinated  greenhouse  gases.  Do  NOT  vent
gases into the atmosphere.

Refrigerant type: R410A

Global warming potential (GWP) value: 2087.5

NOTICE

In  Europe,  the 

greenhouse  gas  emissions

  of  the  total

refrigerant  charge  in  the  system  (expressed  as  tonnes
CO

2

-equivalent)  is  used  to  determine  the  maintenance

intervals. Follow the applicable legislation.

Formula  to  calculate  the  greenhouse  gas  emissions:

GWP value of the refrigerant × Total refrigerant charge [in
kg] / 1000

Please contact your installer for more information.

5.2

To find the contact/helpdesk
number

Prerequisite: 

You  switched  the  permission  level  to  Advanced  end

user.

1

Go  to  [6.3.2]: 

  >  Information  >  Error  handling  >  Contact/

helpdesk number.

6

Troubleshooting

6.1

Symptom: You are feeling too cold
(hot) in your living room

Possible cause

Corrective action

The desired room temperature is
too low (high).

Increase (decrease) the desired
room temperature.

If the problem recurs daily, do
one of the following:

▪ Increase  (decrease)  the  room

temperature preset value.

▪ Adjust  the  room  temperature

schedule.

The desired room temperature
cannot be reached.

Increase the desired leaving
water temperature in accordance
with the heat emitter type.

6.2

Symptom: The water at the tap is
too cold

Possible cause

Corrective action

You ran out of domestic hot
water because of unusual high
consumption.

If you immediately need domestic
hot water, activate the DHW tank
booster mode. However, this
consumes extra energy.

If you can wait, overrule
(increase) the active or next
scheduled desired temperature
so that more hot water will be
produced exceptionally.

If the problems recurs daily, do
one of the following:

▪ Increase 

the 

DHW 

tank

temperature preset value.

▪ Adjust 

the 

DHW 

tank

temperature 

schedule.

Example: 

Program 

to

additionally 

heat 

up 

the

DHW  tank  to  a  preset  value
(Storage  eco  =  lower  tank
temperature) during the day.

The desired DHW tank
temperature is too low.

6.3

Symptom: Heat pump failure

When  the  heat  pump  fails  to  operate,  the  backup  heater  and  anti-
legionella  heater  can  serve  as  an  emergency  heater  and  either
automatically or non-automatically take over the heat load.

▪ When  auto  emergency  is 

activated

  and  a  heat  pump  failure

occurs:

▪ The backup heater will automatically take over the heat load.

▪ The  anti-legionella  heater  will  automatically  take  over  the

domestic hot water production.

▪ When  auto  emergency  is 

not  activated

  and  a  heat  pump  failure

occurs, the domestic hot water and space heating operations will
stop  and  need  to  be  recovered  manually.  The  user  interface  will
then  ask  you  to  confirm  whether  the  backup  heater  or  anti-
legionella heater can take over the heat load or not.

Summary of Contents for Altherma EHBH08CBV

Page 1: ...anual Daikin Altherma Low temperature split English Operation manual Daikin Altherma Low temperature split EHBH04CBV EHBH08CBV EHBH11CBV EHBH16CBV EHVH04S18CBV EHVH08S18CBV EHVH08S26CBV EHVH11S26CBV E...

Page 2: ...to configure your system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation for future reference Target audience End users Documentation set Th...

Page 3: ...edule in the menu structure e NAVIGATING CHANGING SETTINGS Navigates the cursor on the display Navigates through the menu structure Changes settings Selects a mode f OK Confirms a selection Enters a s...

Page 4: ...age Room 2 Press or to select a preset value or Result The mode will return to Scheduled according to the overrule period To set the overrule period Prerequisite You switched the permission level to A...

Page 5: ...it on the home page 3 4 5 Using the DHW tank booster mode To activate the DHW tank booster mode user profile Basic 1 Go to the DHW tank temperature home page Tank 2 Press for more than 5 seconds To ac...

Page 6: ...es and Friday Yes To save the schedule 1 Press select Save schedule and press 2 Select User defined 1 User defined 2 or User defined 3 and press 3 Change the name and press Only applicable for room te...

Page 7: ...modes Running hours Version Energy metering Consumed elec Produced energy Error information Error history Contact helpdesk number Version User interface Indoor unit Outdoor unit User settings Display...

Page 8: ...mperature Modulation A 3 1 1 5 Modulated LWT 0 No Leaving water temperature Emitter type A 3 1 1 7 Emitter type 1 Slow 3 8 3 Domestic hot water control A 4 Setting Default Fill in Type 2 Scheduled onl...

Page 9: ...ct helpdesk number Prerequisite You switched the permission level to Advanced end user 1 Go to 6 3 2 Information Error handling Contact helpdesk number 6 Troubleshooting 6 1 Symptom You are feeling to...

Page 10: ...on of the problem Press again Select to allow the backup heater to take over the heat load Call your local dealer to get the heat pump fixed INFORMATION When the backup heater or anti legionella heate...

Page 11: ......

Page 12: ...4P449973 1 0000000Y 4P449973 1 2016 06 Copyright 2016 Daikin...

Reviews: