4 Installation
Installation manual
7
EBLQ+07CAV3
Daikin Altherma low temperature monobloc
4P403578-1C – 2016.02
1
Lift the outdoor unit.
2
Install the outdoor unit as follows:
1
1×
3
1×
2
1×
4
a
a
a
a
Air outlet
NOTICE
Properly align the unit. Make sure the backside of the unit
does NOT protrude.
3
Remove the protective cardboard and instruction sheet.
b
a
a
Protective cardboard
b
Instruction sheet
NOTICE
To prevent damage to the supporting feet, do NOT tilt the
unit sideways in any way:
4.2.3
To provide drainage
Make sure that condensate can be evacuated properly. When the
unit is in cooling mode, condensate may also form in the hydro part.
When providing drainage, therefore make sure to cover the entire
unit.
NOTICE
If the unit is installed in a cold climate, take adequate
measures so that the evacuated condensate cannot
freeze.
INFORMATION
For information on the available options, contact your
dealer.
NOTICE
Provide at least 300 mm of free space below the unit.
Additionally, make sure the unit is positioned at least
100 mm above the expected level of snow.
4.2.4
To prevent the outdoor unit from falling
over
1
Prepare 2 cables as indicated in the following illustration (field
supply).
2
Place the 2 cables over the outdoor unit.
3
Insert a rubber sheet between the cables and the outdoor unit
to prevent the cable from scratching the paint (field supply).
4
Attach the cable’s ends. Tighten those ends.