3/8
Breadcrumb Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
A.2.1.8
[7-02]
R/W
0: 1 LWT zone
1: 2 LWT zones
A.2.1.9
[F-0D]
R/W
0: Continuous
1: Sample
2: Request
A.2.1.A
[E-04]
R/O
0~1
0: No
A.2.1.B
R/W
0: At unit
1: In room
A.2.1.C
[E-0D]
R/W
0: No
1: Yes
└─ Options
A.2.2.A
[D-02]
R/W
0: No
1: Secondary rtrn
2: Disinf. Shunt
3: Circul. Pump
4: CP & disinf. Sh
A.2.2.B
[C-08]
R/W
0: No
1: Outdoor sensor
2: Room sensor
└────────────────── Control box
A.2.2.E.1
[E-03]
R/W
R/O (*3)(*4)
0: No BUH (*1) (*2)
1: 1 step (*3) (*4)
2: 2 steps
A.2.2.E.2
[5-0D]
R/W
R/O (*3)(*4)
0~5
1: 1P,(1/1+2)
4: 3PN,(1/2)
5: 3PN,(1/1+2)
A.2.2.E.3
[D-01]
R/W
0: No
1: Open tariff
2: Closed tariff
A.2.2.E.4
[E-05]
R/W
0: No
1: Yes
A.2.2.E.5
[C-05]
R/W
1: Thermo ON/OFF
2: C/H request
A.2.2.E.6
[C-06]
R/W
0~2
1: Thermo ON/OFF
└────────────────── Option box
A.2.2.F.1
[C-02]
R/W
0~3
0
A.2.2.F.2
[C-09]
R/W
0: Normally open
1: Normally closed
A.2.2.F.3
[D-08]
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
A.2.2.F.4
[D-09]
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
A.2.2.F.5
[C-08]
R/W
0: No
1: Outdoor sensor
2: Room sensor
A.2.2.F.6
[D-04]
R/O
0: No
1: Yes
└─ Capacities
A.2.3.1
[6-02]
R/W
0~10kW, step: 0,2kW
3kW
A.2.3.2
[6-03]
R/W
0~10kW, step: 0,2kW
3kW
A.2.3.3
[6-04]
R/W
0~10kW, step: 0,2kW
0kW
└─ Space operation
└─ LWT settings
└────────────────── Main
A.3.1.1.1
R/W
0: Fixed
1: Weather dep.
2: Fixed + scheduled
3: WD + scheduled
A.3.1.1.2.1
[9-01]
Temperature range
Minimum temp (heating)
R/W
15~37°C, step: 1°C
25°C
A.3.1.1.2.2
[9-00]
Temperature range
Maximum temp (heating)
R/W
37~55°C, step: 1°C
55°C
A.3.1.1.2.3
[9-03]
Temperature range
Minimum temp (cooling)
R/W
5~18°C, step: 1°C
5°C
A.3.1.1.2.4
[9-02]
Temperature range
Maximum temp (cooling)
R/W
18~22°C, step: 1°C
22°C
A.3.1.1.5
[8-05]
R/W
0: No
1: Yes
A.3.1.1.7
[9-0B]
R/W
0: Quick
1: Slow
└────────────────── Additional
A.3.1.2.1
R/W
0: Fixed
1: Weather dep.
2: Fixed + scheduled
3: WD + scheduled
A.3.1.2.2.1
[9-05]
Temperature range
Minimum temp (heating)
R/W
15~37°C, step: 1°C
25°C
A.3.1.2.2.2
[9-06]
Temperature range
Maximum temp (heating)
R/W
37~55°C, step: 1°C
55°C
A.3.1.2.2.3
[9-07]
Temperature range
Minimum temp (cooling)
R/W
5~18°C, step: 1°C
5°C
A.3.1.2.2.4
[9-08]
Temperature range
Maximum temp (cooling)
R/W
18~22°C, step: 1°C
22°C
└────────────────── Delta T source
A.3.1.3.1
[9-09]
R/W
3~10°C, step: 1°C
5°C
Emitter type
Heating
LWT setpoint mode
External sensor
PCC by digital inputs
BUH: step 1
BUH: step 2 (*1)(*2)
LWT setpoint mode
Modulated LWT
Booster heater
Preferential kWh rate
Contact type main
Ext. backup heat src
Alarm output
External kWh meter 1
External kWh meter 2
DHW operation
Contact type add.
Pump operation mode
Power saving possible
User interface location
External sensor
Backup heater steps
BUH type
DHW pump
Glycol present
Number of LWT zones
(*1) *B*CAV3/CAW1_
(*2) *D*CAV3/CAW1_
(*3) *B*CA3*_(*4) *D*CA3*
4P522033-1A - 2018.06