14 Technical data
Installer reference guide
84
EBLQ+EDLQ011~0W1 + EK(2)CB07CAV3
Daikin Altherma low temperature monobloc
4P538847-1 – 2018.05
Electrical connection diagram
4D116771-1
1
1
X3M: 1-2
X3M: 5-6
X3M: 3-4
X5M: 3-4
X5M: 1-2
X5M: 5-6
X5Y
X2M: 9-10
X8M: 5-4-3
X1M: L-N-PE
A4P: X5A: 1-2-3
X2M: 13-15
X8M: 3-4
X8M: 1-2
X2M: 7-8
X2M: 9-10
X2M: 1a-2a
X1M: L-N-PE
A4P: X5A: 1-2-3
2x0.75
X8M: 6-7
X8M: 8-9
X2M: 20-21
X2M: 22-23
X8M: 10
X2M: 1-2-1a
X2M: 1-2-1a
X8M: 4-5
X2M: 1-2
X8M: 6-7
2
2
2
2
X11M: 3-4-5-6
A7P: X1M: H-C-com
X2M: L-N
A3P: X1M: 1-3
230 V
2x0.75
2x0.75
230 V
230 V
A3P: X1M: C-com-H
230 V
230 V
230 V
230V
3
3
230 V
230 V
K1
X2M: 3-4
F2B: 2+4 + earth
X4M: L-N + earth
Standard part
Monobloc unit
Power supply
unit preferential kWh rate power supply:
400 V or 230 V + earth
unit power supply: 400 V or 230 V + earth
2 core
2 core
3 or 5 core
3 or 5 core
Optional part
Field supply
Optional part
Option box
X1M: L1-L2-L3 or L-N-earth
Preferential kWh rate power supply contact
1 core
communication
communication
2 core
2 core
2 core
2 core
230V
230V
230V
Control box
External room thermostat / Heat pump convector
(main and/or additional zone)
230 V
3 core
Only for normal power supply installation
Backup heater power supply (3 kW): 230 V + earth (F1B)
Only for preferential kWh rate power supply installation
normal kWh rate power supply for unit: 230 V
Booster heater power supply
(3 kW): 230 V + earth
Main: X2M: 1-2
Add: X2M: 1a-2
Only for
(heat pump convector)
Only for *KRTR
(wireless room thermostat)
Only for *KRTW
(wired room thermostat)
2 core
(3m included)
signal
R2T
External sensor
(floor or ambient)
Only for *KRTETS
External indoor thermistor
Electricity pulse
meter input 2
Electricity pulse
meter input 1
Space cooling/heating
On/OFF output
Ext. heat source (eg boiler)
Alarm Output
Only for KRCS01-1
3 core
communication
3 core
Power supply
Optional part
Domestic hot
water tank
Standard: 4 low voltage wires
Optional: 4 high voltage wires
2 low voltage wires
Standard part
Optional part
A5P: P1-P2 user interface
A5P: P1-P2 user interface
Only for *KRUCB*
communication
2 core
communication
2 core
signal
signal
3 core
4 core
4 core for H only operation
5 core for C/H operation
2 core for H only operation
3 core for C/H operation
Control
Box
External outdoor thermistor
Only for EKRSCA1
Optional part
signal
2 core
2 core
2 core
2 core
2 core
signal
signal
2 core
signal
3 way valve
M3S (when *KHW is installed)
selection domestic hot water-floor heating
Control box power supply: 230 V + earth
3 core
Dual setpoint application
(refer to installation manual)
signal
2 core
signal
3 core
Typical configuration
Notes:
- In case of signal cable: keep minimum distance
to power cables > 5 cm
- Available heaters: see combination table
Optional part
Not for E(B/D)LQ*3V3/3W1
DHW pump
Shut-off valve
Field supply
2 core
2 core 230V
X6M
Only for *KHWP*/*HYC*
Only for *KHWS*V3
3 core 3Gx2.5
3 core 3Gx2.5
X4M/X7M: 1-2-earth
X4M: 1-2-earth
Booster heater
R5T - thermistor
water temperature
Booster heater
signal
14.4
ESP curve: Outdoor unit
Note:
A flow error will occur when the minimum water flow rate is not
reached.
0
10
20
30
40
50
60
70
80
90
100
0
5
10
15
20
25
30
35
40
45
50
A (kPa)
B (l/min)
4D117234
C
D
E
A
External static pressure
B
Water/glycol flow rate
C
Operation range
D
Minimum water flow during normal operation.
E
Minimum water flow during defrost operation.
Notes:
▪ About the dashed lines: The operation area is extended to lower
flow rates only in case the unit operates with heat pump only, and
the temperature of the flow medium is sufficiently high. (This does
not apply to start-up operation, defrost operation, and backup
heater operation in case a backup heater is installed.)
▪ The upper operation range is only valid if the flow medium is
water. If glycol is added to the system, the operation range limit is
lower.
▪ Selecting a flow outside the operating area can damage the unit or
cause the unit to malfunction.