7 Installation
Installer reference guide
37
EBLQ+EDLQ011~0W1 + EK(2)CB07CAV3
Daikin Altherma low temperature monobloc
4P538847-1 – 2018.05
INFORMATION
In case of preferential kWh rate power supply, the
necessity of a separate normal kWh rate power supply to
the hydro part of the outdoor unit X3M/5+6 depends on the
type of preferential kWh rate power supply.
A separate connection to the hydro part of the outdoor unit
is required:
▪ if preferential kWh rate power supply is interrupted
when active, OR
▪ if no power consumption by the hydro part of the
outdoor unit is allowed at the preferential kWh rate
power supply when active.
7.7.6
To connect the backup heater power
supply
CAUTION
To guarantee the unit is completely earthed, always
connect the backup heater power supply and the earth
cable.
Make sure that the power supply is in accordance with the backup
heater capacity, as listed in the table below.
Backup
heater type
Backup
heater
capacity
Power
supply
Maximum
running
current
Z
max
(Ω)
*3V
3 kW
1~ 230 V
13 A
—
1
Open the backup heater switch box (see
"7.2.4 To open the
backup heater switch box cover of the outdoor unit" on
page 29
).
2
Route the wiring as follows:
K1M
K5M
X4M
PE
L
N
1
2
3
230 V AC
3 kW
L N
3
Fix the cable with cable ties to the cable tie mountings.
INFORMATION
For more information on the backup heater types, and for
how to configure the backup heater, refer to the
"Configuration" chapter of the installation manual of the
outdoor unit.
7.7.7
To connect the user interface
Connection to outdoor unit
INFORMATION
▪ If control box EKCB07CAV3 is NOT part of the system,
connect the user interface directly to the outdoor unit
according to the instructions below.
▪ If control box EKCB07CAV3 is part of the system,
connect the user interface to the control box. For
instructions, see "Connection to control box" below.
#
Action
1
Connect the user interface cable to the outdoor unit.
X5M
A5P
A5P
1 2
a
b
a
Main user interface
(a)
b
Optional user interface
2
Insert a screwdriver into the slots underneath the user
interface and carefully separate the faceplate from the
wallplate.
The PCB is mounted in the faceplate of the user interface.
Be careful NOT to damage it.
3
Fix the wallplate of the user interface to the wall.
4
Connect as shown in 4A, 4B, 4C or 4D.
5
Reinstall the faceplate onto the wallplate.
Be careful NOT to pinch the wiring when attaching the
frontplate to the unit.
(a)
The main user interface is required for operation, but has to
be ordered separately (mandatory option).
Connection to control box
▪ If you use 1 user interface, you can connect it onto control box
EKCB07CAV3 (for control close to the control box), or in the room
(where used as room thermostat).
▪ If you use 2 user interfaces, you can connect 1 user interface onto
control box EKCB07CAV3 (for control close to the control box) + 1
user interface in the room (where used as room thermostat).