background image

4 Operation

User reference guide

11

EA9W
Daikin Altherma – Low temperature split
4P556076-1 – 2018.10

4.7

Preset values and schedules

4.7.1

Using preset values

About preset values

For some settings in the system, you can define preset values. You
only  need  to  set  these  values  one  time,  then  reuse  the  values  in
other  screens  such  as  the  scheduling  screen.  If  you  later  want  to
change the value, you only have to do it in one place.

To define tank temperature preset values

The  domestic  hot  water  schedule  makes  use  of  different  preset
values:

Preset value

Where used

Comfort setpoint

In schedule if domestic hot water tank
mode is

▪ Schedule only

▪ Sc reheat

Eco setpoint

Reheat setpoint

If domestic hot water tank mode is

▪ Sc reheat

To define energy prices

Only possible if Bivalent is enabled by the installer.

Preset value

Where used

Electricity price >

▪ High

▪ Medium

▪ Low

Used in the weekly schedule screen
when setting the energy prices.

Gas price

4.7.2

Setting the energy prices

In the system, you can set the following energy prices:

▪ a fixed gas price

▪ 3 electricity price levels

▪ a weekly schedule timer for electricity prices.

Refer to the installation manual for more information.

Example: How to set the energy prices on the user interface?

Price

Value in breadcrumb

Fuel: 5.3 euro cents/kWh

[7.6]=5.3

Electricity: 12 euro cents/kWh

[7.5.1]=12

To set the gas price

1

Go to [7.6]: User settings > Gas price.

2

Select the correct gas price.

3

Confirm the changes.

INFORMATION

Price  value  ranging  from  0.00~990  valuta/kWh  (with  2
significant values).

To set the electricity price

1

Go to [7.5.1]/[7.5.2]/[7.5.3]: User settings > Electricity
price > High/Medium/Low.

2

Select the correct electricity price.

3

Confirm the changes.

4

Repeat this for all three electricity prices.

INFORMATION

Price  value  ranging  from  0.00~990  valuta/kWh  (with  2
significant values).

INFORMATION

If no schedule is set, the Electricity price for High is taken
into account.

To set the electricity price schedule timer

1

Go to [7.5.4]: User settings > Electricity price >
Schedule.

2

Program the selection using the scheduling screen.
You can set the High, Medium and Low electricity
prices according to your electricity supplier.

3

Confirm the changes.

INFORMATION

The  values  correspond  with  the  electricity  price  values  for
High,  Medium  and  Low  previously  set.  If  no  schedule  is
set, the electricity price for High is taken into account.

About energy prices in case of an incentive per
kWh renewable energy

An  incentive  can  be  taken  into  account  when  setting  the  energy
prices.  Although  the  running  cost  can  increase,  the  total  operation
cost, taking into account the reimbursement will be optimized.

NOTICE

Make sure to modify the setting of the energy prices at the
end of the incentive period.

To set the gas price in case of an incentive per kWh renewable
energy

Calculate the value for the gas price with the following formula:

▪ Actual gas price+(Incentive/kWh×0.9)

For the procedure to set the gas price, see 

"To set the gas price" on

page 11

.

To set the electricity price in case of an incentive per kWh
renewable energy

Calculate the value for the electricity price with following formula:

▪ Actual electricity price+Incentive/kWh

For  the  procedure  to  set  the  electricity  price,  see 

"To  set  the

electricity price" on page 11

.

Example

This  is  an  example  and  the  prices  and/or  values  used  in  this
example are NOT accurate.

Data

Price/kWh

Gas price

4.08

Electricity price

12.49

Renewable heat incentive per
kWh

5

Calculation of the gas price:

Gas price=Actual gas price+(Incentive/kWh×0.9)

Gas price=4.08+(5×0.9)

Gas price=8.58

Calculation of the electricity price:

Electricity price=Actual electricity price+Incentive/kWh

Electricity price=12.49+5

Electricity price=17.49

Summary of Contents for Altherma EAVZ16S23DA6V

Page 1: ...User reference guide Daikin Altherma Low temperature split English User reference guide Daikin Altherma Low temperature split EAVZ16S18DA6V EAVZ16S23DA6V EAVZ16S18DA9W EAVZ16S23DA9W...

Page 2: ...lpdesk number 17 7 Troubleshooting 17 7 1 To display the help text in case of a malfunction 17 7 2 To check the malfunction history 17 7 3 Symptom You are feeling too cold hot in your living room 17 7...

Page 3: ...health 2 About this document Thank you for purchasing this product Please Read the documentation carefully before operating the user interface to ensure the best possible performance Request the insta...

Page 4: ...the screen darkens Pressing any button or rotating any dial awakens the display The time of non interaction differs depending on the user permission level User or Advanced user 15 min Installer 1 h D...

Page 5: ...Description Additional zone h3 h1 h2 h1 Heat emitter type Underfloor heating Fancoil unit Radiator h2 Leaving water temperature setpoint h3 Room thermostat type External control Hidden Leaving water t...

Page 6: ...he home screen On the home screen you can read out the most important settings that are meant for daily usage The setup of the unit is displayed in a schematic way See 4 2 1 Home screen on page 5 for...

Page 7: ...t automatic changeover according to a monthly schedule To check which space operation mode is currently used The space operation mode is displayed on the home screen When the unit is in heating mode t...

Page 8: ...point screen 2 Adjust the desired leaving water temperature If scheduling is on after changing the desired leaving water temperature The temperature will stay the same as long as there is no scheduled...

Page 9: ...can read out the desired and actual room temperature in the center of the setpoint screen 2 Turn the right dial to adjust the domestic hot water temperature In other modes you can only view the setpo...

Page 10: ...n its most quiet level 4 6 2 Using holiday mode About holiday mode During your holiday you can use the holiday mode to deviate from your normal schedules without having to change them While holiday mo...

Page 11: ...y prices INFORMATION Price value ranging from 0 00 990 valuta kWh with 2 significant values INFORMATION If no schedule is set the Electricity price for High is taken into account To set the electricit...

Page 12: ...settings Electricity price Schedule Program when a certain electricity tariff is valid Example of programming a schedule See 4 7 4 Schedule screen Example on page 12 4 7 4 Schedule screen Example This...

Page 13: ...nt schedule Mon Sat Wed Fri Thu Tue Sun User defined 1 2 Select the Rename option Delete Rename 3 Browse through the character list and confirm the selected character 4 Confirm the new name Usage exam...

Page 14: ...dent curves are defined by two setpoints Setpoint X1 Y2 Setpoint X2 Y1 Weather dependent curve X1 Y1 Y2 X2 Y a X Possible actions on this screen Go through the temperatures Change the temperature Go t...

Page 15: ...day Quiet Electricity price Gas price C Operation Room Space heating cooling Tank B User profile 7 3 Holiday Activation From Till 7 4 Quiet Activation Schedule 7 5 Electricity price High Medium Low Sc...

Page 16: ...temperature In heating mode a lower desired leaving water temperature results in lower energy consumption and better performance Set the desired leaving water temperature in accordance with the heat...

Page 17: ...ur living room Possible cause Corrective action The desired room temperature is too low high Increase decrease the desired room temperature If the problem recurs daily do one of the following Increase...

Page 18: ...dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units MUST be treated at a specialised treatment facil...

Page 19: ......

Page 20: ...4P556076 1 2018 10 Copyright 2018 Daikin...