background image

4 Operation

User reference guide

4

EA9W

Daikin Altherma – Low temperature split

4P556076-1 – 2018.10

3.1

Components in a typical system
layout

d

a

b c

e

f

g

B

C

A

A

Main zone. 

Example: 

Living room.

B

Additional zone. 

Example: 

Bedroom.

C

Technical room. 

Example: 

Garage.

a

Outdoor unit heat pump

b

Indoor unit heat pump

c

Domestic hot water (DHW) tank

d

User interface at the indoor unit

e

User interface used as room thermostat

f

Underfloor heating

g

Radiators, heat pump convectors, or fan coil units

4

Operation

4.1

User interface: Overview

The user interface has the following components:

a

b

c

a

Status indicator

b

LCD screen

c

Dials and buttons

Status indicator

The  LEDs  of  the  status  indicator  light  up  or  blink  to  show  the
operating mode of the unit.

LED

Mode

Description

Blinking blue

Standby

The unit is not in operation.

Continuous blue Operation

The unit is in operation.

Blinking red

Malfunction

A malfunction occurred.

See 

"7.1 To display the help text

in case of a malfunction" on
page 17

 for more information.

LCD screen

The LCD screen has a sleeping function. After a certain time of non-
interaction with the user interface, the screen darkens. Pressing any
button  or  rotating  any  dial  awakens  the  display.  The  time  of  non-
interaction differs depending on the user permission level:

▪ User or Advanced user: 15 min

▪ Installer: 1 h

Dials and buttons

You use the dials and buttons:

▪ To navigate through the screens, menus and settings of the LCD

screen

▪ To set values

a

b

c

d

e

Item

Description

a

Left dial

The LCD shows an arc on the left side of the
display when you can use the left dial.

: Turn, then press the left dial. Navigate

through the menu structure.

: Turn the left dial. Choose a menu item.

: Press the left dial. Confirm your choice

or go to a submenu.

b

Back button

: Press to go back 1 step in the menu structure.

c

Home
button

: Press to go back to the home screen.

d

Help button

: Press to show a help text related to the current

page (if available).

e

Right dial

The LCD shows an arc on the right side of the
display when you can use the right dial.

: Turn, then press the right dial. Change

a value or setting, shown at the right side of the
screen.

:  Turn  the  right  dial.  Navigate  through

the possible values and settings.

:  Press  the  right  dial.  Confirm  your

choice and go to the next menu item.

4.2

Possible screens: Overview

The most common screens are as follows:

+

a

b

c

c2

c1

a

Home screen

b

Main menu screen

c

Lower level screens:

c1

: Setpoint screen

c2

: Detailed screen with values

Summary of Contents for Altherma EAVZ16S23DA6V

Page 1: ...User reference guide Daikin Altherma Low temperature split English User reference guide Daikin Altherma Low temperature split EAVZ16S18DA6V EAVZ16S23DA6V EAVZ16S18DA9W EAVZ16S23DA9W...

Page 2: ...lpdesk number 17 7 Troubleshooting 17 7 1 To display the help text in case of a malfunction 17 7 2 To check the malfunction history 17 7 3 Symptom You are feeling too cold hot in your living room 17 7...

Page 3: ...health 2 About this document Thank you for purchasing this product Please Read the documentation carefully before operating the user interface to ensure the best possible performance Request the insta...

Page 4: ...the screen darkens Pressing any button or rotating any dial awakens the display The time of non interaction differs depending on the user permission level User or Advanced user 15 min Installer 1 h D...

Page 5: ...Description Additional zone h3 h1 h2 h1 Heat emitter type Underfloor heating Fancoil unit Radiator h2 Leaving water temperature setpoint h3 Room thermostat type External control Hidden Leaving water t...

Page 6: ...he home screen On the home screen you can read out the most important settings that are meant for daily usage The setup of the unit is displayed in a schematic way See 4 2 1 Home screen on page 5 for...

Page 7: ...t automatic changeover according to a monthly schedule To check which space operation mode is currently used The space operation mode is displayed on the home screen When the unit is in heating mode t...

Page 8: ...point screen 2 Adjust the desired leaving water temperature If scheduling is on after changing the desired leaving water temperature The temperature will stay the same as long as there is no scheduled...

Page 9: ...can read out the desired and actual room temperature in the center of the setpoint screen 2 Turn the right dial to adjust the domestic hot water temperature In other modes you can only view the setpo...

Page 10: ...n its most quiet level 4 6 2 Using holiday mode About holiday mode During your holiday you can use the holiday mode to deviate from your normal schedules without having to change them While holiday mo...

Page 11: ...y prices INFORMATION Price value ranging from 0 00 990 valuta kWh with 2 significant values INFORMATION If no schedule is set the Electricity price for High is taken into account To set the electricit...

Page 12: ...settings Electricity price Schedule Program when a certain electricity tariff is valid Example of programming a schedule See 4 7 4 Schedule screen Example on page 12 4 7 4 Schedule screen Example This...

Page 13: ...nt schedule Mon Sat Wed Fri Thu Tue Sun User defined 1 2 Select the Rename option Delete Rename 3 Browse through the character list and confirm the selected character 4 Confirm the new name Usage exam...

Page 14: ...dent curves are defined by two setpoints Setpoint X1 Y2 Setpoint X2 Y1 Weather dependent curve X1 Y1 Y2 X2 Y a X Possible actions on this screen Go through the temperatures Change the temperature Go t...

Page 15: ...day Quiet Electricity price Gas price C Operation Room Space heating cooling Tank B User profile 7 3 Holiday Activation From Till 7 4 Quiet Activation Schedule 7 5 Electricity price High Medium Low Sc...

Page 16: ...temperature In heating mode a lower desired leaving water temperature results in lower energy consumption and better performance Set the desired leaving water temperature in accordance with the heat...

Page 17: ...ur living room Possible cause Corrective action The desired room temperature is too low high Increase decrease the desired room temperature If the problem recurs daily do one of the following Increase...

Page 18: ...dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units MUST be treated at a specialised treatment facil...

Page 19: ......

Page 20: ...4P556076 1 2018 10 Copyright 2018 Daikin...