![Daikin Altherma EAVX-D9WG Installer'S Reference Manual Download Page 83](http://html1.mh-extra.com/html/daikin/altherma-eavx-d9wg/altherma-eavx-d9wg_installers-reference-manual_4220413083.webp)
13 Disposal
Installer reference guide
83
EPGA11~ EAVH/9W
Daikin Altherma – Low temperature split
4P556070-1 – 2019.02
13.5.3
To handle the stem cap
▪ The stem cap is sealed where indicated with the arrow. Do NOT
damage it.
▪ After handling the stop valve, tighten the stem cap, and check for
refrigerant leaks.
Item
Tightening torque (N∙m)
Stem cap, liquid side
13.5~16.5
Stem cap, gas side
22.5~27.5
13.5.4
To handle the service cap
▪ ALWAYS use a charge hose equipped with a valve depressor pin,
since the service port is a Schrader type valve.
▪ After handling the service port, tighten the service port cap, and
check for refrigerant leaks.
Item
Tightening torque (N∙m)
Service port cap
11.5~13.9
Summary of Contents for Altherma EAVX-D9WG
Page 103: ......