5

Repeat this action for all other weekdays.

Mon

Sat

Wed

Fri

Thu

Tue

Sun

User defined 1

C

To program the schedule for Saturday and copy it to Sunday

1

Select 

Saturday

.

2

Select 

Edit

.

3

Use the left dial to select an entry and edit the entry
with the right dial.

0

8:00

23:00

--:--

21°C
18°C

--

12

24

Sat

4

Confirm the changes.

5

Select 

Saturday

.

6

Select 

Copy

.

7

Select 

Sunday

.

8

Select 

Paste

.

Result:

Mon

Sat

Wed

Fri

Thu

Tue

Sun

User defined 1

C

To rename the schedule

1

Select the name of the current schedule.

Mon

Sat

Wed

Fri

Thu

Tue

Sun

User defined 1

2

Select 

Rename

.

Delete

Rename

Select

3

(optional) To delete the current schedule name,
browse through the character list until 

 is

displayed, then press to remove the previous
character. Repeat for each character of the schedule
name.

4

To name the current schedule, browse through the
character list and confirm the selected character.
The schedule name can contain up to 15 characters.

5

Confirm the new name.

INFORMATION

Not all schedules can be renamed.

5.9

Weather-dependent curve

5.9.1

What is a weather-dependent curve?

Weather-dependent operation

The unit operates 'weather-dependent' if the desired leaving water or
tank  temperature  is  determined  automatically  by  the  outdoor
temperature.  It  therefore  is  connected  to  a  temperature  sensor  on
the  North  wall  of  the  building.  If  the  outdoor  temperature  drops  or
rises, the unit compensates instantly. Thus, the unit does not have to
wait  for  feedback  by  the  thermostat  to  increase  or  decrease  the
temperature  of  the  leaving  water  or  tank.  Because  it  reacts  more
quickly,  it  prevents  high  rises  and  drops  of  the  indoor  temperature
and water temperature at tap points.

Advantage

Weather-dependent operation reduces energy consumption.

Weather-dependent curve

To  be  able  to  compensate  for  differences  in  temperature,  the  unit
relies on its weather-dependent curve. This curve defines how much
the  temperature  of  the  tank  or  leaving  water  must  be  at  different
outdoor  temperatures.  Because  the  slope  of  the  curve  depends  on
local  circumstances  such  as  climate  and  the  insulation  of  the
building, the curve can be adjusted by an installer or user.

Types of weather-dependent curve

There are 2 types of weather-dependent curves:

▪ 2-points curve

▪ Slope-offset curve

Which type of curve you use to make adjustments, depends on your
personal  preference.  See 

"5.9.4  Using  weather-dependent

curves"

 [

4

 16].

Availability

The weather-dependent curve is available for:

▪ Main zone - Heating

▪ Main zone - Cooling

▪ Additional zone - Heating

▪ Additional zone - Cooling

▪ Tank (only available to installers)

INFORMATION

To  operate  weather-dependent,  correctly  configure  the
setpoint  of  the  main  zone,  additional  zone  or  tank.  See

"5.9.4 Using weather-dependent curves"

 [

4

 16].

5.9.2

2-points curve

Define the weather-dependent curve with these two setpoints:

▪ Setpoint (X1, Y2)

▪ Setpoint (X2, Y1)

Example

Y1

Y2

X1

X2

a

Summary of Contents for Altherma 3 WS EWSAH06D 9W

Page 1: ...Operation manual Daikin Altherma 3 WS English Operation manual Daikin Altherma 3 WS EWSAH06D 9W EWSAH06UD 9W EWSAX06D 9W EWSAX06UD 9W 1 2 3 9 A B C Z 1 2 3 9...

Page 2: ...d in by installer 20 11 1 Configuration wizard 20 11 2 Settings menu 20 1 About this document Thank you for purchasing this product Please Read the documentation carefully before operating the user in...

Page 3: ...ace any objects containing water on the unit CAUTION Do NOT place any objects or equipment on top of the unit Do NOT sit climb or stand on the unit Units are marked with the following symbol This mean...

Page 4: ...If not you can purge air immediately If yes make sure that the room where you want to purge air is sufficiently ventilated Reason Refrigerant might leak into the water circuit and subsequently into th...

Page 5: ...l room thermostat control the protection is NOT guaranteed 1 Go to C 2 Operation Space heating cooling Operation Space heating cooling Tank Off On C 2 2 Set operation to On or Off To change the desire...

Page 6: ...ugh the temperatures Change the temperature Go to the next temperature Confirm changes and proceed More information For more information see also 5 4 Turning operation ON or OFF 411 5 6 Space heating...

Page 7: ...s and buttons To navigate through the screens menus and settings of the LCD screen To set values a b c d e Item Description a Left dial The LCD shows an arc on the left side of the display when you ca...

Page 8: ...tpoint Eco setpoint Reheat setpoint Schedule WD curve type 8 Information Energy data Malfunction history Dealer information Sensors Actuators Operation modes About Connection status Running hours B Us...

Page 9: ...off e Space operation mode Cooling Heating f Outdoor quiet mode f1 6 Measured outdoor temperature a f2 Quiet mode active f3 Central water loop circuit g Indoor unit domestic hot water tank g1 Floor s...

Page 10: ...ace heating cooling Shows the applicable symbol of your unit Put the unit in heating mode or cooling mode You cannot change the mode on heating only models 5 Tank Set the domestic hot water tank tempe...

Page 11: ...ain active However if you turn it OFF while disinfection is running an AH error occurs 1 Go to C 3 Operation Tank Operation Tank Off On Space heating cooling C 3 2 Set operation to On or Off 5 5 Readi...

Page 12: ...esired room temperature The temperature will stay the same as long as there is no scheduled action The desired room temperature will return to its scheduled value whenever a scheduled action occurs Yo...

Page 13: ...About powerful operation Powerful operation allows the domestic hot water to be heated by the backup heater Use this mode on days when there is more hot water usage than usual To check if powerful ope...

Page 14: ...entry with the right dial You can program up to 6 actions each day On the bar a high temperature has a darker colour than a low temperature 0 6 00 8 30 17 30 20 C 18 C 22 00 18 C 21 C 12 24 Mon Note...

Page 15: ...or on the North wall of the building If the outdoor temperature drops or rises the unit compensates instantly Thus the unit does not have to wait for feedback by the thermostat to increase or decrease...

Page 16: ...temperature for all ambient temperatures Examples Weather dependent curve when slope is selected X1 X2 c d e Y1 Y2 Y3 Y4 a b Weather dependent curve when offset is selected Y1 Y2 Y3 Y4 X1 X2 a b c d...

Page 17: ...s Y2 a Y1 a X1 a X2 a OK Cold OK Hot Cold OK Cold Cold Cold Hot Hot OK Hot Cold Hot Hot a See 5 9 2 2 points curve 415 6 Energy saving tips Tips about room temperature Make sure the desired room tempe...

Page 18: ...ierce or burn refrigerant cycle parts Do NOT use cleaning materials or means to accelerate the defrosting process other than those recommended by the manufacturer Be aware that the refrigerant inside...

Page 19: ...er activates this via the Malfunctioning main menu screen When the heat pump fails or will appear on the user interface Possible cause Corrective action Heat pump is damaged See 8 1 To display the hel...

Page 20: ...ncy 9 5 Number of zones 4 4 Backup heater Voltage 9 3 2 Maximum capacity 9 3 9 Main zone Emitter type 2 7 Control 2 9 Setpoint mode 2 4 Schedule 2 1 WD curve type 2 E Additional zone only if 4 4 1 dua...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...4P675761 1C 2023 02 Copyright 2021 Daikin 4P675761 1 C 00000004 Verantwortung f r Energie und Umwelt...

Reviews: