5 Operation

Operation manual

13

EWSAH/X06(U)D
Daikin Altherma 3 WS
4P675761-1C – 2023.02

INFORMATION

When  the  DHW  tank  mode  is  reheat,  the  risk  for  capacity
shortage  and  comfort  problem  is  significant.  In  case  of
frequent  reheat  operation,  space  heating/cooling  function
is regularly interrupted.

5.7.2

Scheduled mode

In  scheduled  mode,  the  DHW  tank  produces  hot  water
corresponding  to  a  schedule.  The  best  time  to  allow  the  tank  to
produce hot water is at night, because the space heating demand is
lower.

Example: 

t

60°C

00:00

07:00

50°C

15°C

40°C

14:00

21:00

1

2

3

4

5

Tt

T

t

DHW tank temperature

t

Time

▪ Initially,  the  DHW  tank  temperature  is  the  same  as  the

temperature  of  the  domestic  water  entering  the  DHW  tank
(example: 

15°C

).

▪ At 00:00 the DHW tank is programmed to heat up the water to a

preset value (example: 

Comfort

 = 

60°C

).

▪ During  the  morning,  you  consume  hot  water  and  the  DHW  tank

temperature decreases.

▪ At 14:00 the DHW tank is programmed to heat up the water to a

preset value (example: 

Eco

 = 

50°C

). Hot water is available again.

▪ During  the  afternoon  and  evening,  you  consume  hot  water  again

and the DHW tank temperature decreases again.

▪ At 00:00 the next day, the cycle repeats.

5.7.3

Sch reheat mode

In  scheduled  +  reheat  mode,  the  domestic  hot  water  control  is  the
same  as  in  scheduled  mode.  However,  when  the  DHW  tank
temperature drops below a preset value (=reheat tank temperature –
hysteresis  value;  example:  35°C),  the  DHW  tank  heats  up  until  it
reaches  the  reheat  set  point  (example:  45°C).  This  ensures  that  a
minimum amount of hot water is available at all times.

Example: 

t

Tt

60°C

00:00

07:00

50°C

45°C

15°C

14:00

21:00

35°C

1

2

4

5

3

T

t

Domestic hot water tank temperature

t

Time

5.7.4

Using DHW powerful operation

About powerful operation

Powerful operation

 allows the domestic hot water to be heated by

the  backup  heater.  Use  this  mode  on  days  when  there  is  more  hot
water usage than usual.

To check if powerful operation is active

If 

 is displayed on the home screen, powerful operation is active.

Activate or deactivate 

Powerful operation

 as follows:

1

Go to [5.1]: 

Tank

 > 

Powerful operation

2

Turn powerful operation 

Off

 or 

On

.

Usage example: You immediately need more hot water

You are in the following situation:

▪ You already consumed most of your domestic hot water.

▪ You  cannot  wait  for  the  next  scheduled  action  to  heat  up  the

domestic hot water tank.

Then  you  can  activate  powerful  operation.  The  domestic  hot  water
tank will start heating up the water to the 

Comfort

 temperature.

INFORMATION

When  powerful  operation  is  active,  the  risk  of  space
heating/cooling and capacity shortage comfort problems is
significant.  In  case  of  frequent  domestic  hot  water
operation,  frequent  and  long  space  heating/cooling
interruptions will happen.

5.8

Schedule screen: Example

This  example  shows  how  to  set  a  room  temperature  schedule  in
heating mode for the main zone.

INFORMATION

The procedures to program other schedules are similar.

To program the schedule: overview

Example: 

You want to program the following schedule:

Mon

Sat

Wed

Fri

Thu

Tue

Sun

User defined 1

Prerequisite: 

The  room  temperature  schedule  is  only  available  if

room  thermostat  control  is  active.  If  leaving  water  temperature
control is active, you can program the main zone schedule instead.

1

Go to the schedule.

2

(optional) Clear the content of the whole week schedule or the
content of a selected day schedule.

3

Program the schedule for 

Monday

.

4

Copy the schedule to the other weekdays.

5

Program the schedule for 

Saturday

 and copy it to 

Sunday

.

6

Give the schedule a name.

To go to the schedule

1

Go to [1.1]: 

Room

 > 

Schedule

.

2

Set scheduling to 

Yes

.

3

Go to [1.2]: 

Room

 > 

Heating schedule

.

Summary of Contents for Altherma 3 WS EWSAH06D 9W

Page 1: ...Operation manual Daikin Altherma 3 WS English Operation manual Daikin Altherma 3 WS EWSAH06D 9W EWSAH06UD 9W EWSAX06D 9W EWSAX06UD 9W 1 2 3 9 A B C Z 1 2 3 9...

Page 2: ...d in by installer 20 11 1 Configuration wizard 20 11 2 Settings menu 20 1 About this document Thank you for purchasing this product Please Read the documentation carefully before operating the user in...

Page 3: ...ace any objects containing water on the unit CAUTION Do NOT place any objects or equipment on top of the unit Do NOT sit climb or stand on the unit Units are marked with the following symbol This mean...

Page 4: ...If not you can purge air immediately If yes make sure that the room where you want to purge air is sufficiently ventilated Reason Refrigerant might leak into the water circuit and subsequently into th...

Page 5: ...l room thermostat control the protection is NOT guaranteed 1 Go to C 2 Operation Space heating cooling Operation Space heating cooling Tank Off On C 2 2 Set operation to On or Off To change the desire...

Page 6: ...ugh the temperatures Change the temperature Go to the next temperature Confirm changes and proceed More information For more information see also 5 4 Turning operation ON or OFF 411 5 6 Space heating...

Page 7: ...s and buttons To navigate through the screens menus and settings of the LCD screen To set values a b c d e Item Description a Left dial The LCD shows an arc on the left side of the display when you ca...

Page 8: ...tpoint Eco setpoint Reheat setpoint Schedule WD curve type 8 Information Energy data Malfunction history Dealer information Sensors Actuators Operation modes About Connection status Running hours B Us...

Page 9: ...off e Space operation mode Cooling Heating f Outdoor quiet mode f1 6 Measured outdoor temperature a f2 Quiet mode active f3 Central water loop circuit g Indoor unit domestic hot water tank g1 Floor s...

Page 10: ...ace heating cooling Shows the applicable symbol of your unit Put the unit in heating mode or cooling mode You cannot change the mode on heating only models 5 Tank Set the domestic hot water tank tempe...

Page 11: ...ain active However if you turn it OFF while disinfection is running an AH error occurs 1 Go to C 3 Operation Tank Operation Tank Off On Space heating cooling C 3 2 Set operation to On or Off 5 5 Readi...

Page 12: ...esired room temperature The temperature will stay the same as long as there is no scheduled action The desired room temperature will return to its scheduled value whenever a scheduled action occurs Yo...

Page 13: ...About powerful operation Powerful operation allows the domestic hot water to be heated by the backup heater Use this mode on days when there is more hot water usage than usual To check if powerful ope...

Page 14: ...entry with the right dial You can program up to 6 actions each day On the bar a high temperature has a darker colour than a low temperature 0 6 00 8 30 17 30 20 C 18 C 22 00 18 C 21 C 12 24 Mon Note...

Page 15: ...or on the North wall of the building If the outdoor temperature drops or rises the unit compensates instantly Thus the unit does not have to wait for feedback by the thermostat to increase or decrease...

Page 16: ...temperature for all ambient temperatures Examples Weather dependent curve when slope is selected X1 X2 c d e Y1 Y2 Y3 Y4 a b Weather dependent curve when offset is selected Y1 Y2 Y3 Y4 X1 X2 a b c d...

Page 17: ...s Y2 a Y1 a X1 a X2 a OK Cold OK Hot Cold OK Cold Cold Cold Hot Hot OK Hot Cold Hot Hot a See 5 9 2 2 points curve 415 6 Energy saving tips Tips about room temperature Make sure the desired room tempe...

Page 18: ...ierce or burn refrigerant cycle parts Do NOT use cleaning materials or means to accelerate the defrosting process other than those recommended by the manufacturer Be aware that the refrigerant inside...

Page 19: ...er activates this via the Malfunctioning main menu screen When the heat pump fails or will appear on the user interface Possible cause Corrective action Heat pump is damaged See 8 1 To display the hel...

Page 20: ...ncy 9 5 Number of zones 4 4 Backup heater Voltage 9 3 2 Maximum capacity 9 3 9 Main zone Emitter type 2 7 Control 2 9 Setpoint mode 2 4 Schedule 2 1 WD curve type 2 E Additional zone only if 4 4 1 dua...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...4P675761 1C 2023 02 Copyright 2021 Daikin 4P675761 1 C 00000004 Verantwortung f r Energie und Umwelt...

Reviews: