6
|
Troubleshooting
User reference guide
51
EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596825-1 – 2019.10
6.3 Symptom: You are feeling too cold (hot) in your living room
6.4 Symptom: The water at the tap is too cold
Possible cause
Corrective action
You ran out of domestic hot water
because of unusual high consumption.
If you immediately need domestic hot
water, activate the DHW tank booster
mode. However, this consumes extra
energy. See
If you can wait, overrule (increase) the
active or next scheduled desired
temperature so that more hot water
will be produced exceptionally. See
If the problems recurs daily, do one of
the following:
▪
Increase the DHW tank temperature
preset value. See
▪
Adjust the DHW tank temperature
schedule.
Example:
Program to
additionally heat up the DHW tank to
a preset value (
Storage eco
=
lower tank temperature) during the
day.
See
40] and
42].
The desired DHW tank temperature is
too low.
6.5 Symptom: Heat pump failure
When the heat pump fails to operate, the backup heater can serve as an
emergency heater and either automatically or non-automatically take over the
heat load.
▪
When auto emergency is
activated
and a heat pump failure occurs, the backup
heater will automatically take over the heat load.
▪
When auto emergency is
not activated
and a heat pump failure occurs, the
domestic hot water and space heating operations will stop and need to be
recovered manually. The user interface will then ask you to confirm whether the
backup heater can take over the heat load or not.
When the heat pump fails, will appear on the user interface.