Operation

User reference guide

40

EHFZ03S18DJ3V

Daikin Altherma 3 R F

4P596825-1 – 2019.10

3.7 Preset values and schedules

3.7.1 Using preset values

About preset values

You  can  define  preset  values  for  multiple  controls.  Preset  values  make  it  easy  to
use the same value in many places (schedules and room temperature home page
(  and  )). If you later want to change the value, you only have to do it in one place.

To define preset values

1

Go to [7.4]:   > 

User settings

 > 

Preset values

.

2

Select  for  which  control  you  want  to  define  a  preset  value. 

Example: 

Room

temperature

.

3

Select a preset value and press  . 

Example: 

Comfort (heating)

.

4

Select a temperature and press  .

Possible preset values

Control

Preset value

Where used

Room
temperature

Comfort

Room temperature schedules

Room  temperature  home  page
(   and  )  if  user  profile  =

Detailed

Eco

LWT main

Comfort

Main leaving water temperature
schedules

Eco

Tank
temperature

Storage comfort

DHW tank temperature schedule
if DHW tank mode is

Scheduled

Sch reheat

Storage eco

Reheat

DHW tank temperature schedule
if DHW tank mode = Sch
reheat

Quiet level

Used when quiet mode is set to

On

3.7.2 Using and programming schedules

About schedules

Depending  on  your  system  layout  and  installer  configuration,  schedules
(predefined and/or user‑defined) for multiple controls may be available.

You can:

Select which schedules you currently want to use.

Program  your  own  schedules  if  the  predefined  schedules  are  not  satisfactory.
The actions you can program are control specific.

Summary of Contents for Altherma 3 R F

Page 1: ...User reference guide Daikin Altherma 3 R F EHFZ03S18DJ3V...

Page 2: ...re control 25 3 4 8 Leaving water temperature control Using leaving water temperature control according to a schedule 26 3 4 9 Leaving water temperature control Using leaving water temperature control...

Page 3: ...desk number 49 6 Troubleshooting 50 6 1 To check the error history 50 6 2 To check the warning history 50 6 3 Symptom You are feeling too cold hot in your living room 51 6 4 Symptom The water at the t...

Page 4: ...ser interface location Number of LWT zones Pump operation mode Domestic hot water settings A 2 2 DHW operation DHW tank type DHW pump Thermostats A 2 2 Contact type main Contact type add External sens...

Page 5: ...ter control A 4 Setting Fill in Type Maximum setpoint INFORMATION There is a risk of a space heating capacity shortage comfort problem when selecting 6 0D 0 A 4 1 Domestic hot water Type Reheat only I...

Page 6: ...of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure tha...

Page 7: ...above a certain concentration Possible chemical symbols are Pb lead 0 004 Waste batteries must be treated at a specialized treatment facility for reuse By ensuring waste batteries are disposed of corr...

Page 8: ...allation good practices reference data Format Digital files on http www daikineurope com support and manuals product information Addendum book for optional equipment Additional info about how to insta...

Page 9: ...injury NOTICE Indicates a situation that could result in equipment or property damage INFORMATION Indicates useful tips or additional information Symbols used on the unit Symbol Explanation Before in...

Page 10: ...hot water 2 3 1 Components in a typical system layout g A d b a f e c B C A Main zone Example Living room B Additional zone Example Bedroom C Technical room Example Garage a Outdoor unit heat pump b...

Page 11: ...age Malfunction information If a malfunction occurs is displayed on the home pages Press to display more information about the malfunction On Off Turn ON or OFF one of the controls room temperature le...

Page 12: ...de Heating Unit is operating Desired room temperature preset value Comfort daytime Desired room temperature preset value Eco nighttime On the room temperature home page Desired room temperature accord...

Page 13: ...nd edit in the menu structure depends on your user permission level End user Default user mode Adv end user As an advanced end user you can read out and edit more information To set the user permissio...

Page 14: ...Running hours Version Energy metering Consumed elec Produced energy Error information Error history Contact helpdesk number Version User interface Indoor unit Outdoor unit User settings Display Tempe...

Page 15: ...home pages is displayed 2 Press again to display the next home page if any 3 3 2 Using the menu structure About the menu structure You can use the menu structure to read out and configure settings tha...

Page 16: ...l leaving water temperature control Room temperature control is automatically turned OFF To check if a control is turned ON or OFF 1 Go to the home page of the control Example Room temperature home pa...

Page 17: ...on modes The heat pump is a heating only model The system can heat up a space but NOT cool down a space 3 4 3 Determining which temperature control you are using To determine which temperature control...

Page 18: ...aving water set point and room temperature set point are Yes NOT linked You can set the leaving water set point on the home page No Linked by their preset values You can set the preset values in the m...

Page 19: ...leaving water temperature Condition Leaving water set point is NOT linked with the room temperature set point Only change this if the desired room temperature cannot be reached Define preset values Co...

Page 20: ...d value at the next scheduled action To change the mode from scheduled to preset value Prerequisite User profile Detailed 1 Go to the room temperature home page Room 2 Press or to select a preset valu...

Page 21: ...the schedule will be used again If user profile Basic then you can temporarily overrule the room temperature schedule by pressing or Situation Description 15 20 18 0 C 15 20 19 0 C 15 20 Scheduled tem...

Page 22: ...set value Desired temperature custom temperature 21 C After 2 hours the schedule will be used again 17 20 20 C To set the overrule period Prerequisite You switched the permission level to Advanced end...

Page 23: ...tat control Using the leaving water temperature home pages INFORMATION The leaving water is the water that is sent to the heat emitters The desired leaving water temperature is set by your installer i...

Page 24: ...value can be modified To adjust overrule the leaving water temperature linked to room temperature setpoint INFORMATION To see if the leaving water temperature setpoint is linked to the room temperatu...

Page 25: ...l means that you only control the leaving water temperature To control the leaving water temperature you can do the following You can Location Read out the desired leaving water temperature main addit...

Page 26: ...47 C INFORMATION In case of weather dependency an offset value can be modified 3 4 9 Leaving water temperature control Using leaving water temperature control NOT according to a schedule To adjust th...

Page 27: ...In case of weather dependency an offset value can be modified 3 5 Domestic hot water control NOTICE Disinfection mode Even if you turn OFF domestic hot water operation via the DHW tank temperature hom...

Page 28: ...t Domestic hot water tank temperature t Time INFORMATION There is a risk of a space heating capacity shortage comfort problem when selecting 6 0D 0 A 4 1 Domestic hot water Type Reheat only In case of...

Page 29: ...lower Example t 60 C 00 00 07 00 50 C 15 C 40 C 14 00 21 00 1 2 3 4 5 Tt Tt Domestic hot water tank temperature t Time Initially the DHW tank temperature is the same as the temperature of the domesti...

Page 30: ...the DHW tank temperature home page 431 3 5 6 Using the DHW tank booster mode 432 3 7 Preset values and schedules 440 3 5 4 Scheduled reheat mode In scheduled reheat mode the domestic hot water control...

Page 31: ...esult You can read out the desired reheat temperature 2 Press or to adjust To read out and overrule the active or next scheduled desired temperature in scheduled mode or scheduled reheat mode 1 Go to...

Page 32: ...er profile Basic If is displayed the DHW tank booster mode is active In user profile Detailed If is selected the DHW tank booster mode is active To activate the DHW tank booster mode user profile Basi...

Page 33: ...1 Press for more than 4 seconds Result Your user permission level is now End user The user interface displays the default home page 3 6 2 Using quiet mode About quiet mode You can use quiet mode to d...

Page 34: ...capacity of the system However during the afternoon the baby is sleeping and you want it to be quiet Then you can do the following Prerequisite You switched the permission level to Advanced end user...

Page 35: ...is activated and or running 1 Press to go to one of the home pages 2 Check the following If is displayed Then One of the following holiday modes is activated Holiday mode Away is activated but NOT run...

Page 36: ...domestic hot water operation during your holiday INFORMATION You can only change the From and Until settings in the End user level For changing the other settings you have to switch to Adv end user l...

Page 37: ...configuration 3 6 4 Reading out information To read out information Prerequisite You switched the permission level to Advanced end user 1 Go to 6 Information Possible read out information In menu You...

Page 38: ...nd user 1 Go to 7 1 1 User settings Display Contrast To configure the backlit LCD time of the user interface Prerequisite You switched the permission level to Advanced end user 1 Go to 7 1 2 User sett...

Page 39: ...people cannot Room On OFF Turn ON or OFF the room temperature control LWT On OFF Turn ON or OFF the leaving water temperature main additional control Tank On OFF Turn ON or OFF the domestic hot water...

Page 40: ...Possible preset values Control Preset value Where used Room temperature Comfort Room temperature schedules Room temperature home page and if user profile Detailed Eco LWT main Comfort Main leaving wat...

Page 41: ...during the night Quiet mode Program when the unit has to use which quiet mode level Level 1 Level 2 Level 3 OFF Only for field supplied domestic hot water pump for secondary return Domestic hot water...

Page 42: ...The procedures to program other schedules are similar In this example Room temperature schedule in heating mode Monday Tuesday Wednesday Thursday Friday Saturday Sunday To program the schedule 1 Selec...

Page 43: ...Predefined schedules Room temperature leaving water temperature main Desired temperature Preset value Comfort Desired temperature Preset value Eco Predefined 1 Mon Fri 07 00 09 00 17 00 23 00 Sat Sun...

Page 44: ...ing water or tank temperature is determined automatically by the outdoor temperature It therefore is connected to a temperature sensor on the North wall of the building If the outdoor temperature drop...

Page 45: ...weather dependent curve with these two setpoints Setpoint X1 Y2 Setpoint X2 Y1 Example Set weather dependent heating Confirm Adjust Scroll Tt Ta X1 Y1 Y2 X2 X1 X2 Examples of outdoor ambient temperatu...

Page 46: ...ints You cannot configure the curve with temperatures that are higher or lower than the set maximum and minimum setpoints for that zone or for the tank When the maximum or minimum setpoint is reached...

Page 47: ...s You can use the holiday mode Tips about leaving water temperature In heating mode a lower desired leaving water temperature results in lower energy consumption and better performance Set the desired...

Page 48: ...t charge in kg 1000 Please contact your installer for more information WARNING FLAMMABLE MATERIAL The refrigerant inside this unit is mildly flammable WARNING The appliance shall be stored in a room w...

Page 49: ...e guide 49 EHFZ03S18DJ3V Daikin Altherma 3 R F 4P596825 1 2019 10 5 2 To find the contact helpdesk number Prerequisite You switched the permission level to Advanced end user 1 Go to 6 3 2 Information...

Page 50: ...below you can try to solve the problem yourself For any other problem contact your installer You can find the contact helpdesk number via the user interface 6 1 To check the error history Prerequisit...

Page 51: ...W tank temperature preset value See 3 7 1 Using preset values 440 Adjust the DHW tank temperature schedule Example Program to additionally heat up the DHW tank to a preset value Storage eco lower tank...

Page 52: ...the system a Various malfunctions Check if is displayed on the home pages of the user interface You can press to display more information about the malfunction a We recommend to purge air with the air...

Page 53: ...in Altherma 3 R F 4P596825 1 2019 10 7 Relocation 7 1 Overview Relocation If you want to relocate parts of your system user interface indoor unit outdoor unit DHW tank contact your installer You can f...

Page 54: ...1 2019 10 8 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units MUST b...

Page 55: ...rvice company Qualified company which can perform or coordinate the required service to the product Installation manual Instruction manual specified for a certain product or application explaining how...

Page 56: ...4P596825 1 2019 10 Copyright 2019 Daikin Verantwortung f r Energie und Umwelt...

Reviews: