background image

7 Maintenance and service

Operation manual

18

EBLA09~16DA + EDLA09~16DA

Daikin Altherma 3 M

4P620243-1B – 2021.02

▪ Use  a  weekly  schedule  for  your  normal  space  heating  or  cooling

needs. If necessary, you can easily deviate from the schedule:

▪ For  shorter  periods:  You  can  overrule  the  scheduled  room

temperature  until  the  next  scheduled  action. 

Example: 

When

you have a party, or when you are leaving for a couple of hours.

▪ For longer periods: You can use the holiday mode.

Tips about DHW tank temperature

▪ Use a weekly schedule for your normal domestic hot water needs

(only in scheduled mode).

▪ Program to heat up the DHW tank to a preset value (

Comfort

 =

higher  DHW  tank  temperature)  during  the  night,  because  then
space heating demand is lower.

▪ If  heating  up  the  DHW  tank  once  at  night  is  not  sufficient,

program to additionally heat up the DHW tank to a preset value
(

Eco

 = lower DHW tank temperature) during the day.

▪ Make  sure  the  desired  DHW  tank  temperature  is  NOT  too  high.

Example: 

After installation, lower the DHW tank temperature daily

by 1°C and check if you still have enough hot water.

▪ Program  to  turn  ON  the  domestic  hot  water  pump  only  during

periods of the day when instant hot water is necessary. 

Example:

In the morning and evening.

7

Maintenance and service

7.1

Overview: Maintenance and
service

The installer has to perform a yearly maintenance. You can find the
contact/helpdesk number via the user interface.

1

Go to [8.3]: 

Information

 > 

Dealer information

.

As end user, you have to:

▪ Keep the area around the unit clean.

▪ Keep the user interface clean with a soft damp cloth. Do NOT use

any detergents.

▪ Regularly check if the water pressure is above 1 bar.

Refrigerant

This  product  contains  fluorinated  greenhouse  gases.  Do  NOT  vent
gases into the atmosphere.

Refrigerant type: R32

Global warming potential (GWP) value: 675

NOTICE

Applicable  legislation  on 

fluorinated  greenhouse  gases

requires  that  the  refrigerant  charge  of  the  unit  is  indicated
both in weight and CO

2

 equivalent.

Formula  to  calculate  the  quantity  in  CO

2

  equivalent

tonnes:

  GWP  value  of  the  refrigerant  ×  total  refrigerant

charge [in kg] / 1000

Please contact your installer for more information.

WARNING: MILDLY FLAMMABLE MATERIAL

The refrigerant inside this unit is mildly flammable.

WARNING

The appliance shall be stored so as to prevent mechanical
damage and in a well-ventilated room without continuously
operating  ignition  sources  (example:  open  flames,  an
operating gas appliance or an operating electric heater).

WARNING

▪ Do NOT pierce or burn refrigerant cycle parts.

▪ Do NOT use cleaning materials or means to accelerate

the  defrosting  process  other  than  those  recommended
by the manufacturer.

▪ Be  aware  that  the  refrigerant  inside  the  system  is

odourless.

WARNING

The  refrigerant  inside  the  unit  is  mildly  flammable,  but
normally  does  NOT  leak.  If  the  refrigerant  leaks  in  the
room  and  comes  in  contact  with  fire  from  a  burner,  a
heater, or a cooker, this may result in fire, or the formation
of a harmful gas.

Turn  off  any  combustible  heating  devices,  ventilate  the
room,  and  contact  the  dealer  where  you  purchased  the
unit.

Do  NOT  use  the  unit  until  a  service  person  confirms  that
the  part  from  which  the  refrigerant  leaked  has  been
repaired.

8

Troubleshooting

Contact

For  the  symptoms  listed  below,  you  can  try  to  solve  the  problem
yourself. For any other problem, contact your installer. You can find
the contact/helpdesk number via the user interface.

1

Go to [8.3]: 

Information

 > 

Dealer information

.

8.1

To display the help text in case of a
malfunction

In  case  of  a  malfunction,  the  following  will  appear  on  the  home
screen depending on the severity:

: Error

: Malfunction

You  can  get  a  short  and  a  long  description  of  the  malfunction  as
follows:

1

Press the left dial to open the main menu and go to

Malfunctioning

.

Result: 

A short description of the error and the error

code is displayed on the screen.

2

Press   in the error screen.

Result: 

A long description of the error is displayed

on the screen.

8.2

To check the malfunction history

Conditions: 

The user permission level is set to advanced end user.

1

Go to [8.2]: 

Information

 > 

Malfunction history

.

You see a list of the most recent malfunctions.

Summary of Contents for Altherma 3 M EDLA09-16D3V3

Page 1: ...Operation manual Daikin Altherma 3 M English Operation manual Daikin Altherma 3 M EBLA09 16DAV3 EBLA09 16DAW1 EBLA09 16DA3V3 EBLA09 16DA3W1 EDLA09 16DAV3 EDLA09 16DAW1 EDLA09 16DA3V3 EDLA09 16DA3W1...

Page 2: ...wizard 20 11 2 Settings menu 20 1 About this document Thank you for purchasing this product Please Read the documentation carefully before operating the user interface to ensure the best possible per...

Page 3: ...lace any objects containing water on the unit CAUTION Do NOT place any objects or equipment on top of the unit Do NOT sit climb or stand on the unit Units are marked with the following symbol This mea...

Page 4: ...rant might leak into the water circuit and subsequently into the room when you purge air from the heat emitters or collectors 3 About the system Depending on the system layout the system can Heat up a...

Page 5: ...ation to On or Off To change the desired room temperature During room temperature control you can use the room temperature setpoint screen to read out and adjust the desired room temperature 1 Go to 1...

Page 6: ...mation see also 5 4 Turning operation ON or OFF 411 5 6 Space heating cooling control 412 5 8 Schedule screen Example 414 5 9 Weather dependent curve 415 User reference guide 4 3 Domestic hot water To...

Page 7: ...5 min of non interaction with the user interface the screen darkens Pressing any button or rotating any dial awakens the display Dials and buttons You use the dials and buttons To navigate through the...

Page 8: ...Quiet Activation Schedule Level 1 5 Setpoint range Heating minimum Heating maximum Cooling minimum Cooling maximum 4 Space heating cooling Operation mode Operation mode schedule Room comfort setpoint...

Page 9: ...ive Powerful operation mode active c Emergency Heat pump failure and system operates in Emergency mode or heat pump is forced off d Current date and time e Smart energy e1 Smart energy is available vi...

Page 10: ...in zone Shows the applicable symbol for your main zone emitter type Set the leaving water temperature for the main zone 3 Additional zone Restriction Only displayed if there are two leaving water temp...

Page 11: ...ng operation ON b Space heating cooling operation OFF Tank heating operation 55 21 35 45 c 55 21 35 45 d c Tank heating operation ON d Tank heating operation OFF 5 4 2 To turn ON or OFF Space heating...

Page 12: ...ng Only heating mode Cooling Only cooling mode Automatic The operation mode changes automatically between heating and cooling based on the outdoor temperature Restricted per month according to the Ope...

Page 13: ...hot water is at night because the space heating demand is lower Example t 60 C 00 00 07 00 50 C 15 C 40 C 14 00 21 00 1 2 3 4 5 Tt Tt DHW tank temperature t Time Initially the DHW tank temperature is...

Page 14: ...control is active you can program the main zone schedule instead 1 Go to the schedule 2 optional Clear the content of the whole week schedule or the content of a selected day schedule 3 Program the s...

Page 15: ...ter of the schedule name 4 To name the current schedule browse through the character list and confirm the selected character The schedule name can contain up to 15 characters 5 Confirm the new name IN...

Page 16: ...to the next temperature Confirm changes and proceed 5 9 3 Slope offset curve Slope and offset Define the weather dependent curve by its slope and offset Change the slope to differently increase or dec...

Page 17: ...one Cooling WD curve Additional zone Heating 3 5 Additional zone Heating WD curve Additional zone Cooling 3 6 Additional zone Cooling WD curve Zone Go to Tank Restriction Only available to installers...

Page 18: ...Formula to calculate the quantity in CO2 equivalent tonnes GWP value of the refrigerant total refrigerant charge in kg 1000 Please contact your installer for more information WARNING MILDLY FLAMMABLE...

Page 19: ...re occurs the backup heater automatically takes over the heat load and the booster heater in the optional tank takes over the domestic hot water production When Emergency is set to Manual and a heat p...

Page 20: ...type of building for domestic purposes LWT Leaving water temperature Water temperature at the water outlet of the unit 11 Installer settings Tables to be filled in by installer 11 1 Configuration wiza...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...4P620243 1B 2021 02 Copyright 2020 Daikin 4P620243 1 B 0000000V Verantwortung f r Energie und Umwelt...

Reviews: