To check if powerful operation is active

If 

 is displayed on the home screen, powerful operation is active.

Activate or deactivate 

Powerful operation

 as follows:

1

Go to [5.1]: 

Tank

 > 

Powerful operation

2

Turn powerful operation 

Off

 or 

On

.

Usage example: You immediately need more hot water

You are in the following situation:

▪ You already consumed most of your domestic hot water.

▪ You  cannot  wait  for  the  next  scheduled  action  to  heat  up  the

domestic hot water tank.

Then  you  can  activate  powerful  operation.  The  domestic  hot  water
tank will start heating up the water to the 

Comfort

 temperature.

INFORMATION

When  powerful  operation  is  active,  the  risk  of  space
heating/cooling and capacity shortage comfort problems is
significant.  In  case  of  frequent  domestic  hot  water
operation,  frequent  and  long  space  heating/cooling
interruptions will happen.

5.8

Schedule screen: Example

This  example  shows  how  to  set  a  room  temperature  schedule  in
heating mode for the main zone.

INFORMATION

The procedures to program other schedules are similar.

To program the schedule: overview

Example: 

You want to program the following schedule:

Mon

Sat

Wed

Fri

Thu

Tue

Sun

User defined 1

Prerequisite: 

The  room  temperature  schedule  is  only  available  if

room  thermostat  control  is  active.  If  leaving  water  temperature
control is active, you can program the main zone schedule instead.

1

Go to the schedule.

2

(optional) Clear the content of the whole week schedule or the
content of a selected day schedule.

3

Program the schedule for 

Monday

.

4

Copy the schedule to the other weekdays.

5

Program the schedule for 

Saturday

 and copy it to 

Sunday

.

6

Give the schedule a name.

To go to the schedule

1

Go to [1.1]: 

Room

 > 

Schedule

.

2

Set scheduling to 

Yes

.

3

Go to [1.2]: 

Room

 > 

Heating schedule

.

To clear the content of the week schedule

1

Select the name of the current schedule.

Mon

Sat

Wed

Fri

Thu

Tue

Sun

User defined 1

2

Select 

Delete

.

Delete

Rename

Select

3

Select 

OK

 to confirm.

To clear the content of a day schedule

1

Select the day of which you want to clear the
content. For example 

Friday

Mon

Sat

Wed

Fri

Thu

Tue

Sun

User defined 1

C

2

Select 

Delete

.

Delete

Edit

Copy

3

Select 

OK

 to confirm.

To program the schedule for Monday

1

Select 

Monday

.

Mon

Sat

Wed

Fri

Thu

Tue

Sun

User defined 1

2

Select 

Edit

.

Delete

Edit

Copy

3

Use the left dial to select an entry and edit the entry
with the right dial. You can program up to 6 actions
each day. On the bar, a high temperature has a
darker colour than a low temperature.

0

6:00
8:30

17:30

20°C
18°C

22:00

--:--

18°C

--

21°C

12

24

Mon

Note: 

To clear an action, set its time as the time of

the previous action.

4

Confirm the changes.

Result: 

The schedule for Monday is defined. The

value of the last action is valid until the next
programmed action. In this example, Monday is the
first day you programmed. Thus, the last
programmed action is valid up to the first action of
next Monday.

Summary of Contents for Altherma 3 M EDLA09-16D3V3

Page 1: ...Operation manual Daikin Altherma 3 M English Operation manual Daikin Altherma 3 M EBLA09 16DAV3 EBLA09 16DAW1 EBLA09 16DA3V3 EBLA09 16DA3W1 EDLA09 16DAV3 EDLA09 16DAW1 EDLA09 16DA3V3 EDLA09 16DA3W1...

Page 2: ...wizard 20 11 2 Settings menu 20 1 About this document Thank you for purchasing this product Please Read the documentation carefully before operating the user interface to ensure the best possible per...

Page 3: ...lace any objects containing water on the unit CAUTION Do NOT place any objects or equipment on top of the unit Do NOT sit climb or stand on the unit Units are marked with the following symbol This mea...

Page 4: ...rant might leak into the water circuit and subsequently into the room when you purge air from the heat emitters or collectors 3 About the system Depending on the system layout the system can Heat up a...

Page 5: ...ation to On or Off To change the desired room temperature During room temperature control you can use the room temperature setpoint screen to read out and adjust the desired room temperature 1 Go to 1...

Page 6: ...mation see also 5 4 Turning operation ON or OFF 411 5 6 Space heating cooling control 412 5 8 Schedule screen Example 414 5 9 Weather dependent curve 415 User reference guide 4 3 Domestic hot water To...

Page 7: ...5 min of non interaction with the user interface the screen darkens Pressing any button or rotating any dial awakens the display Dials and buttons You use the dials and buttons To navigate through the...

Page 8: ...Quiet Activation Schedule Level 1 5 Setpoint range Heating minimum Heating maximum Cooling minimum Cooling maximum 4 Space heating cooling Operation mode Operation mode schedule Room comfort setpoint...

Page 9: ...ive Powerful operation mode active c Emergency Heat pump failure and system operates in Emergency mode or heat pump is forced off d Current date and time e Smart energy e1 Smart energy is available vi...

Page 10: ...in zone Shows the applicable symbol for your main zone emitter type Set the leaving water temperature for the main zone 3 Additional zone Restriction Only displayed if there are two leaving water temp...

Page 11: ...ng operation ON b Space heating cooling operation OFF Tank heating operation 55 21 35 45 c 55 21 35 45 d c Tank heating operation ON d Tank heating operation OFF 5 4 2 To turn ON or OFF Space heating...

Page 12: ...ng Only heating mode Cooling Only cooling mode Automatic The operation mode changes automatically between heating and cooling based on the outdoor temperature Restricted per month according to the Ope...

Page 13: ...hot water is at night because the space heating demand is lower Example t 60 C 00 00 07 00 50 C 15 C 40 C 14 00 21 00 1 2 3 4 5 Tt Tt DHW tank temperature t Time Initially the DHW tank temperature is...

Page 14: ...control is active you can program the main zone schedule instead 1 Go to the schedule 2 optional Clear the content of the whole week schedule or the content of a selected day schedule 3 Program the s...

Page 15: ...ter of the schedule name 4 To name the current schedule browse through the character list and confirm the selected character The schedule name can contain up to 15 characters 5 Confirm the new name IN...

Page 16: ...to the next temperature Confirm changes and proceed 5 9 3 Slope offset curve Slope and offset Define the weather dependent curve by its slope and offset Change the slope to differently increase or dec...

Page 17: ...one Cooling WD curve Additional zone Heating 3 5 Additional zone Heating WD curve Additional zone Cooling 3 6 Additional zone Cooling WD curve Zone Go to Tank Restriction Only available to installers...

Page 18: ...Formula to calculate the quantity in CO2 equivalent tonnes GWP value of the refrigerant total refrigerant charge in kg 1000 Please contact your installer for more information WARNING MILDLY FLAMMABLE...

Page 19: ...re occurs the backup heater automatically takes over the heat load and the booster heater in the optional tank takes over the domestic hot water production When Emergency is set to Manual and a heat p...

Page 20: ...type of building for domestic purposes LWT Leaving water temperature Water temperature at the water outlet of the unit 11 Installer settings Tables to be filled in by installer 11 1 Configuration wiza...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...4P620243 1B 2021 02 Copyright 2020 Daikin 4P620243 1 B 0000000V Verantwortung f r Energie und Umwelt...

Reviews: