Installation manual

2

If any refrigerant has leaked out during the installation
work, ventilate the room.
The refrigerant produces a toxic gas if exposed to
flames.

After all installation is complete, check to make sure
that no refrigerant is leaking.
The refrigerant produces a toxic gas if exposed to
flames.

When installing or relocating the system, be sure to keep the
refrigerant circuit free from substances other than the specified
refrigerant (R410A), such as air.
Any presence of air or other foreign substance in the refrigerant
circuit causes an abnormal pressure rise or rupture, resulting in
injury.

During pump down operation, stop the compressor before
removing the refrigerant piping.
If the compressor is still running and the stop valve is open
during pump-down, air will be sucked in when the refrigerant
piping is removed, causing abnormal pressure in the freezer
cycle which will lead to breakage and even to injury.

During installation, attach the refrigerant piping securely before
running the compressor.
If the compressor is not attached and the stop valve is open
during pump-down, air will be sucked in when the compressor is
running, causing abnormal pressure in the freezer cycle which
will lead to breakage and even to injury.

Be sure to establish an earth. Do not earth the unit to
a utility pipe, surge absorber, or telephone earth.
Incomplete earth may cause electrical shock. A high
surge current from lightning or other sources may
cause damage to the air conditioner.

Be sure to install an earth leakage breaker.
Failure to do so may cause electrical shock.

CAUTION

Do not install the air conditioner in a place where there
is danger of exposure to inflammable gas leakage.
If the gas leaks and builds up around the unit, it may
catch fire.

Establish drain piping according to the instructions of this
manual.
Inadequate piping may cause flooding.

Note for installing the outdoor unit.
In cold areas where the outside air temperature remains below
or around the freezing-point for a few days, the outdoor unit's
drain may freeze. If so, it is recommended to install an electric
heater in order to protect drain from freezing.

Tighten the flare nut according to the specified method such as
with a torque wrench.
If the flare nut is tightened too hard, the flare nut may crack after
a long time and cause refrigerant leakage.

Sound pressure level is less than 70dB(A).

Accessories

Accessories supplied with the outdoor unit:

Precautions for selecting the location

1

The equipment is not intended for use in a potentially explosive
atmosphere.

2

Choose a place solid enough to bear the weight and vibration of
the unit, where the operation noise will not be amplified.

3

Choose a location where the hot air discharged from the unit or
the operation noise will not cause a nuisance to the neighbours
of the user.

4

Avoid places near a bedroom and the like, so that the operation
noise will cause no trouble.

5

There must be sufficient space for carrying the unit into and out
of the site.

6

There must be sufficient space for air passage and no
obstructions around the air inlet and the air outlet.

7

The site must be free from the possibility of flammable gas
leakage in a nearby place.
Locate the unit so that the noise and the discharged hot air will
not annoy the neighbours.

8

Install units, power cords and inter-unit cables at least 3 m away
from television and radio sets. This is to prevent interference to
images and sounds.
Depending on radio wave conditions, electromagnetic
interference may still occur even if installed more than 3 m away.

Installation manual

1

Drain socket (A)

1

Drain cap (B)

2

Drain receiver (C)

3

Insulation tape (D)

1

Reducer assembly

1

Fluorinated greenhouse gases label

1

Multilingual fluorinated greenhouse 
gases label

1

Screws for field installation

4

Make sure to provide adequate measures in order to
prevent that the outdoor unit will be used as a shelter
by small animals.

Small animals making contact with electrical parts can
cause malfunctions, smoke or fire. Please instruct the
customer to keep the area around the unit clean.

Summary of Contents for 4MXS80E3V3B2

Page 1: ...INSTALLATION MANUAL 4MXS80E3V3B2 5MXS90E3V3B2 R410A Split series ...

Page 2: ...Certificato C 07 Σημείωση όπως καθορίζεται στο A και κρίνεται θετικά από το B σύμφωνα με το Πιστοποιητικό C 08 Nota tal como estabelecido em A e com o parecer positivo de B de acordo com o Certificado C 09 Примечание как указано в A и в соответствии с положительным решением B согласно Свидетельству C 10 Bemærk som anført i A og positivt vurderet af B i henhold til Certifikat C 11 Information enlig...

Page 3: ...8 6 15 m 2 15 m 2 7 5 m 1 7 5 m 1 1 2 3 A 1 2 3 4 5 L N 5 50 Hz 230 V A B 3 C D E 1 E D C B A 2 S102 S2 S52 A BC D E ON SERVICE MONITOR S15 S10 S23 S24 S22 S21 S20 A A H05RN A B C D E 3 1 4 4 P 2 5 A A A A A B B B B B B B B 1 2 3 4 5 6 7 ...

Page 4: ...r leakage electrical shock or fire Install the air conditioner on a solid base that can support the weight of the unit An inadequate base or incomplete installation may cause injury in the event the unit falls off the base Electrical work should be carried out in accordance with the installation manual and the national electrical wiring rules or code of practice Insufficient capacity or incomplete...

Page 5: ... air temperature remains below or around the freezing point for a few days the outdoor unit s drain may freeze If so it is recommended to install an electric heater in order to protect drain from freezing Tighten the flare nut according to the specified method such as with a torque wrench If the flare nut is tightened too hard the flare nut may crack after a long time and cause refrigerant leakage...

Page 6: ...nstall the outdoor unit with its suction side facing the wall Never install the outdoor unit at a site where the suction side may be exposed directly to wind To prevent exposure to wind install a baffle plate on the air discharge side of the outdoor unit In heavy snowfall areas select an installation site where the snow will not affect the unit Construct a large canopy Construct a pedestal Install...

Page 7: ...gth per room is 3 m If the outdoor unit is positioned higher than the indoor units See figure 2 If the outdoor unit is positioned otherwise i e lower than one or more indoor units See figure 3 Refrigerant piping work Installing the outdoor unit When installing the outdoor unit refer to Precautions for selecting the location on page 2 and Indoor outdoor unit installation drawings on page 3 If drain...

Page 8: ...oupling meter needle does not go back If it does go back this may indicate presence of moisture or leaking from connecting parts Repeat steps 2 4 after checking all connecting parts and slightly loosening and retightening the nuts 5 Remove covers from liquid stop valve and gas stop valve 6 Turn the liquid stop valve s rod 90 degrees counterclockwise with a hexagonal wrench to open the valve Close ...

Page 9: ...ipe bends should be as gentle as possible Use a pipe bender for bending Bending radius should be 30 to 40 mm or larger Selection of copper and heat insulation materials When using commercial copper pipes and fittings observe the following Insulation material polyethylene foam Heat transfer rate 0 041 to 0 052 W mK 0 035 to 0 045 kcal mh C Refrigerant gas pipe s surface temperature reaches 110 C ma...

Page 10: ...are tool Clutch type Clutch type Ridgid Wing nut type Imperial A 0 0 5 mm 1 0 1 5 mm 1 5 2 0 mm 1 Flare s inner surface must be flaw free 2 The pipe end must be evenly flared in a perfect circle 3 Make sure that the flare nut is fitted WARNING Do not use mineral oil on flared part Prevent mineral oil from getting into the system as this would reduce the lifetime of the units Never use piping which...

Page 11: ...rds or connections from a star system as they may cause overheating electrical shock or fire Do not use locally purchased electrical parts inside the product and do not branch the power for the drain pump etc from the terminal block Doing this may cause electrical shock or fire Be sure to install an earth leakage breaker This unit uses an inverter which means that an earth leakage breaker capable ...

Page 12: ...f the indoor unit which is set for priority room is operating at Powerful operation distribution of capacity to other indoor units will be reduced This means that the room of which the indoor unit is set for priority room will be cooled or heated much quicker than other rooms Indoor or outdoor unit quiet operation priority Pressing the Quiet operation button on the remote controller of the indoor ...

Page 13: ...cannot be directly checked Wiring error check This product is capable of automatic correction of wiring errors Press the wiring error check switch SW3 on the outdoor unit service PCB Approximately 15 20 minutes after the switch is pressed the errors in the connection wiring will be corrected However the wiring error check switch will not function the first 3 minutes after the safety breaker was tu...

Page 14: ...p For 4 rooms LED 5 does not light up 2 If the outside air temperature is 5 C the wiring error check function will not operate 3 After wiring error check operation is completed LED indication will continue until ordinary operation starts This is normal 4 Follow procedures as mentioned on the service sticker on the rear side of the service cover Cooling Heating Temperature difference between inlet ...

Page 15: ......

Page 16: ...3P401524 4 2015 02 Copyright 2015 Daikin ...

Reviews: