![background image](http://html.mh-extra.com/html/daikin/4mxm110pvlt/4mxm110pvlt_service-manual_501133010.webp)
Electrical Box
Si121293EC
8
Removal Procedure
3. Remove the electrical
box.
1
Detach the clamp of the
fan motor lead wire.
2
3
Disconnect the
connector [S70].
Release the fan motor
lead wire from the 3
hooks.
[S70]: fan motor
When reassembling, put the
fan motor lead wire through
the back of the fan motor so
as not to be entangled with
the outdoor fan.
4
Detach the 3 clamps.
5
Disconnect the 5
connectors for the
electronic expansion
valve coils.
[S20] (white): room A
[S21] (red): room B
[S22] (blue): room C
[S23] (yellow): room D
[S24] (white): room E
4-room models do not have
[S24].
Step
Procedure
Points
(R22548)
Clamp
(R17956)
[S70]
Hook
Fan motor
lead wire
Lead wire
Outdoor fan
(R3249)
(R17970)
[S20] [S21] [S22] [S23]
[S24]
(R18093)