Si12-796
Removal of Electrical Box
Removal Procedure
7
3
Remove the earth wire.
4
Remove 1 screw of the
terminal board.
5
Release the tab on the
top right of the terminal
board.
6
Pull out the terminal
board and open it.
Glass tube fuse and varistor
cannot be replaced
individually because lead-
free soldering is provided.
Step
Procedure
Points
(R2222)
(R2223)
(R2224)
Tab
Glass tube fuse (Soldered)
Varister
(R2225)