![background image](http://html.mh-extra.com/html/daikin/4mkd90bvm/4mkd90bvm_service-manual_501127026.webp)
Removal of Compressor
Si12-796
24
Removal Procedure
10.Removal of Compressor
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1
Remove the terminal
cover.
Be careful to avoid burning
the compressor terminals or
the nameplate.
2
3
Disconnect the
terminals of the
compressor.
Remove the overload
protector.
4
There is the nut fixing
the compressor.
Remove the nut with a
spanner.
Terminal cover
(R2274)
U(red)
V(yellow)
W(blue)
N
(brown)
Terminal nameplate
(R2275)
Overload relay