25

26

Cooling only use

Options

Control system

  Indoor unit

  Outdoor unit

No.

1

2

3

4

5
6
7
8
9

10
11
12

Wired remote controller*

1

Wired remote controller 
cord

5-room centralised controller*

2

Wiring adaptor for time clock/remote controller*

3

(Normal open pulse contact/normal open contact)

Titanium apatite photocatalytic air-purifying filter*

4

Photocatalytic deodorising filter with frame*

5

Photocatalytic deodorising filter without frame*

5

Air-purifying filter with frame*

6

Air-purifying filter without frame*

6

Wireless remote controller loss prevention chain
Suction grille
Insulation kit for high humidity

Length 3 m (shielded wire)
Length 8 m (shielded wire)

C(F)DK(X)S25-50C C(F)DK(X)S60C

KRC72

KRP413AB1S

KAF970A46




KAZ917B41 
KAZ917B42 
KAF925B41 
KAF925B42 

KKF917A4 

No.

1
2
3
4

Item 

Central remote controller*
Unified on/off controller*
Schedule timer*
Interface adaptor for DIII-NET use

DCS302CA61
DCS301BA61

DST301BA61

KRP928BB2S

Note: * Interface adaptor for DIII-NET use (KRP928BB2S) is also required for each indoor unit. 

KPW945A4

KPW5E112

Wall-mounted type

Wall-mounted type

Duct-connected type

Floor-standing 

type

Floor/ceiling-

suspended dual type

Duct-connected type

Floor-standing type

Floor/ceiling-suspended dual type

Item

KAF968A42

KDGF19A45

KDT25N50

KDT25N32

KDT25N63

Notes: *1. One set includes 5 pieces for 5 units.

   *2. One set includes 1 piece for 1 unit.

5-room centralised 

controller

KRC72

Remote controller loss 

prevention chain

KKF917A4

Air direction adjustment grille

KPW945A4

Drain plug

KKP937A4

Central remote controller

DCS302CA61

Unified on/off controller

DCS301BA61

Schedule timer

DST301BA61

Item

Decoration panel

Fresh air intake kit
Sealing member of air discharge outlet
Panel spacer

Wiring adaptor for electrical appendices

*

2

Installation box for adaptor PCB

Replacement long-life filter

Remote controller

Wired type

*

1

Heat pump use

Wireless type

Remote sensor (for indoor temperature)

Adaptor for wiring

*

2

Notes:  *1. Wiring for wired remote controller should be obtained locally.

*2. Installation box for adaptor PCB (KRP1BA101) is necessary.

KDDQ44XA60
KDBH44BA60

KDBQ44BA60A

KRP4AA53

KRP1BA57

KRP1BA101

KRCS01-1B

BYFQ60B8W1

KAFQ441BA60

BRC1C61

BRC7E530W
BRC7E531W

Compact multi flow ceiling-mounted cassette type

1

3

2

4
5
6
7
8
9

10

No.

CDK(X)S25/35EA

BRC944B2

BRCW901A03
BRCW901A08



Titanium apatite photocatalytic 
air-purifying filter 

KAF970A46

Direct installation type

Specifications

Options

Notes: *1. 3 m (BRCW901A03) or 8 m (BRCW901A08) length wired remote controller cord is necessary.
            *2. A wiring adaptor (KRP413AB1S) is also required for each indoor unit.
            *3. Time clock and other devices should be obtained locally.
            *4. Filter is a standard accessory. It should be replaced approximately every 3 years.
            *5. The photocatalytic deodorising filter is a standard accessory. It can be reused indefinitely if it is exposed to direct sunlight once every 6 months.
                  This accessory is only required if the original filter is damaged or lost, etc.
            *6. The air-purifying filter is a standard accessory. It should be replaced approximately once every 3 months. This accessory is required for the replacement of filters.

KKF917A4

KKF910A4

KKF910A4

Floor/ceiling-suspended dual type

FLXS25BVMA

126 (268)
153 (325)

37/31/28
37/31/29

53
53

FLXS35GVMA

143 (304)
163 (346)

38/32/29
39/33/30

54
55

FLXS50GVMA

190 (402)
202 (427)

47/39/36
46/35/33

63
62

FLXS60GVMA

200 (424)
213 (452)

48/41/39
47/37/34

64
63

Cooling 

Heating

Cooling 

Heating  

Cooling 

Heating  

 
 

Liquid (flare)

Gas (flare)

Drain

Liquid (flare)

Gas (flare)

Drain

Cooling 

Heating

Cooling 

Heating

  /s

(cfm)

dB (A)

dB (A)

mm

kg

mm

ø12.7

16

ø9.5

17

1 phase, 220-240 V/220-230 V, 50/60 Hz

Almond white

5 steps, quiet and automatic

Microcomputer control

490 x 1,050 x 200

ø6.4

ø18.0

Both liquid and gas pipes

Model name

Power supply
Front grille colour

Airflow rate
(H)

Sound level
(H/L/SL)

Sound power
level (H)

Fan speed
Temperature control
Dimensions (H x W x D)
Machine weight

Piping 

connections

Heat insulation

Compact multi flow ceiling-mounted cassette type

Note: 

Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.

Model name

Power supply

Airflow rate 
(H)

Sound level* 
(H/L)

Sound power 
level (H)

Fan speed
Temperature control
Unit dimensions (H x W x D)
Machine weight

Piping  
connections

Heat insulation

  /s

(cfm)

dB (A)

dB (A)

mm

kg

mm

Model

Colour

Dimensions (H x W x D)

Weight

mm

kg

Panel 
(option)

FFQ35BV1B

167 (353)

32/25

49

FFQ50BV1B

200 (424)

36/27

53

FFQ60BV1B

250 (530)

41/32

58

FFQ25BV1B

150 (318)

29.5/24.5

46.5

FFQ35BV1B

167 (353)
167 (353)

32/25
32/25

49
49

FFQ50BV1B

200 (424)
200 (424)

36/27
36/27

53
53

FFQ60BV1B

250 (530)
250 (530)

41/32
41/32

58
58

FFQ25BV1B

150 (318)
150 (318)
29.5/24.5
29.5/24.5

46.5
46.5

Cooling only

Heat pump

1 phase, 220-240 V, 50 Hz

2 steps

Microcomputer control

286 x 575 x 575

17.5
ø6.4

VP20 (External Dia. 26/Internal Dia. 20)

Both liquid and gas pipes

BYFQ60B8W1

White

2.7

ø9.5

ø12.7

ø9.5

ø12.7

55 x 700 x 700

Cooling 

Heating

Measurement conditions
1. Cooling operation data is based on the following conditions: indoor temp. 27

°

CDB, 19

°

CWB; outdoor temp. 35

°

CDB; piping length 5 m.

2. Heating operation data is based on the following conditions: indoor temp. 20

°

CDB; outdoor temp. 7

°

CDB, 6

°

CWB; piping length 5 m.

3. Sound levels are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.

Wired remote 

controller

BRC944B2

No.

1
2

Item

Air direction adjustment grille
Drain plug

3MXS52L

3MKS58L

3MXS68L

3MKS68L

4MXS80L

4MKS80L

5MXS100L 5MKS100L

KKP937A4*

1

KKP945A4*

2

Summary of Contents for 3MKS58L

Page 1: ...rganization DAIKIN INDUSTRIES THAILAND LTD Scope of Registration THE DESIGN DEVELOPMENT AND MANUFACTURE OF AIR CONDITIONERS AND THE COMPONENTS INCLUDING COMPRESSORS USED FOR THEM All of the Daikin Group s business facilities and subsidiaries in Japan are certified under the ISO 14001 international standard for environment management Warning Daikin products are manufactured for export to numerous c...

Page 2: ... so it is easy to select a model that blends in unobtrusively A single compact outdoor unit allows you to make more efficient use of available space in the installation location such as a balcony The individual indoor units in different rooms the living room study and bedrooms for example can be controlled independently to match your family s lifestyle Super Multi NX can make your home more comfor...

Page 3: ...y efficient 5MK X S series The DC motor swing compressor and other advanced technologies make for energy efficient operation that achieves high COPs The quiet operation mode helps create a more pleasant living environment DC inverter power control provides comfortable temperature control The wide range of indoor unit options provides ample choice A single compact outdoor unit reduces installation ...

Page 4: ...nger magnetic force produced is beneficial particularly at low load conditions 1 A neodymium magnet is approximately 10 times stronger than a standard ferrite magnet 2 The torque created by the change in power between the iron and magnet parts Note Data are based on studies conducted under controlled conditions at a Daikin laboratory Neodymium magnets are used in the pink coloured area 1 2 3 Indoo...

Page 5: ...er rooms may decrease slightly Priority Room Setting also allows Outdoor Unit Quiet Operation to be selected by one command from the priority room If Priority Room Setting has not been set the Outdoor Unit Quiet Operation button must be pushed on the wireless remote controller of all indoor units operating at that time Convenient remote controllers Preferential air conditioning Priority setting wi...

Page 6: ...pe Compact multi flow ceiling mounted cassette type 700 mm width 900 1 100 mm width Cooling only Possible combinations for indoor and outdoor units Heat pump Model Capacity class Model Capacity class Connectable to up to 5 indoor units 2 0 kW 7 1 kW 6 0 kW 5 0 kW 3 5 kW 2 5 kW 2 0 kW 3MKS58L 3MKS68L 4MKS80L 3MXS52L 3MXS68L 4MXS80L Option 5MKS100L 5MXS100L Cooling only Heat pump 5MKS100LVMA 5MXS100...

Page 7: ...ful for preventing circuit breakers from being overloaded by the use of multiple air conditioners and other electrical devices The function is easily activated from the remote controller by pushing the ECONO button This diagram is a representation for illustrative purposes only Maximum capacity decreases during Econo Mode requiring more time to reach the set temperature Running current and power c...

Page 8: ... Purifying Filter Bacteria Removal Test Testing method dropping method Result certificate No 012553 1 and 012553 2 Testing organisation Japan Spinners Inspecting Foundation Clean air Internal structure 3D ait filter catches dust Titanium apatite photocatalytic air purifying filter The remote controller with a backlit liquid crystal display and luminescent control buttons also features a built in W...

Page 9: ... duct Suspension bolt Air discharge grille Signal receiver wire Length 1 900 mm Chamber 700 mm width type 900 1 100 mm width type CDK X S25 35EA 2 5 kW class 3 5 kW class 5 0 kW class 6 0 kW class Cooling only Heat pump CDKS25EAVMA CDXS25EAVMA CDKS35EAVMA CDXS35EAVMA Cooling only Heat pump CDKS25CVMA FDXS25CVMA CDKS35CVMA FDXS35CVMA CDKS50CVMA FDXS50CVMA CDKS60CVMA FDXS60CVMA Duct Connected Type S...

Page 10: ...r discharge outlet option Note For 3 way or 2 way flow installation the sealing member for air discharge outlet option must be used to close off the unused outlet s Air discharge patterns can be selected according to installation Multi Flow System Quiet sound level of only 24 5 dB A Two selectable temperature sensors Both indoor unit and wired remote controller option contain temperature sensors T...

Page 11: ...ndoor unit Wall mounted type FTK X S20 25 35 CDK X S FDXS FTK X S50 60 71 Floor standing type Floor ceiling suspended dual type FVXS FLXS Compact multi flow ceiling mounted cassette type FFQ Duct connected type Power Airflow Dual Flaps Comfortable Airflow Wide Angle Louvres 3 D Airflow Comfort Control Indoor Unit Quiet Operation Outdoor Unit Quiet Operation Night Quiet Mode Inverter Powerful Opera...

Page 12: ... effective cooling heating operation Wide Angle Louvres Comfort Airflow Mode Auto Fan Speed Programme Dry Function Automatic Operation Inverter Powerful Operation Priority Room Setting Home Leave Operation Indoor Unit On Off Switch 24 Hour On Off Timer Night Set Mode See pages 12 and 14 This timer can be preprogrammed with settings for day of the week time of day temperature and operation on off A...

Page 13: ...ons H x W x D Machine weight Piping connections Heat insulation Liquid flare Gas flare Drain dB A dB A mm kg mm Heat pump Cooling only FTKS25KVMA FTKS20KVMA FTKS35KVMA 188 399 42 26 23 58 10 FTKS50KAVMA 245 519 44 35 32 60 FTKS60KAVMA 270 572 45 36 33 61 FTKS71KAVMA 290 614 46 37 34 62 ø15 9 White 5 steps quiet and automatic Microcomputer control ø6 4 Both liquid and gas pipes 38 25 22 54 295 x 80...

Page 14: ...d be replaced approximately every 3 years 5 The photocatalytic deodorising filter is a standard accessory It can be reused indefinitely if it is exposed to direct sunlight once every 6 months This accessory is only required if the original filter is damaged or lost etc 6 The air purifying filter is a standard accessory It should be replaced approximately once every 3 months This accessory is requi...

Page 15: ... 9 9 3 0 14 9 9 4 2 8 15 0 9 4 3 0 15 0 9 4 3 2 15 6 9 4 3 2 15 6 9 1 2 9 15 6 10 1 2 1 13 4 10 1 2 3 13 7 9 9 2 4 13 7 9 3 2 5 14 4 9 1 2 6 15 0 9 1 2 8 15 0 10 1 2 3 14 3 9 9 2 4 14 3 9 3 2 5 15 0 9 1 2 6 15 0 9 1 2 8 15 0 9 9 2 6 14 3 9 1 2 6 15 0 4MKS80LVMA Combinations of indoor units Total capacity kW Rated Min _Max Total power consumption W Rated Min _Max Total current A Rated Min _Max Outd...

Page 16: ...0 1 84 3 18 2 80 2 59 2 40 3 57 3 33 2 50 2 38 2 08 1 92 1 77 3 04 2 69 2 50 2 32 3 45 3 23 2 80 2 50 2 33 3 23 2 50 2 27 2 00 1 85 1 71 2 92 2 59 2 41 2 24 3 33 2 00 2 50 3 50 4 54 4 99 5 41 2 50 3 50 4 35 4 80 5 22 3 18 4 00 4 45 4 86 3 57 4 01 2 50 3 34 4 17 4 62 5 04 3 04 3 85 4 28 4 70 3 45 3 87 2 80 3 57 4 01 3 23 2 50 3 19 4 00 4 45 4 87 2 92 3 71 4 15 4 56 3 33 Capacity of each indoor unit...

Page 17: ... 20 35 35 25 25 25 25 25 35 20 20 50 2 00 1 63 2 95 2 50 1 63 3 24 3 50 1 65 4 52 5 00 1 77 5 84 4 00 1 80 5 96 4 50 1 80 6 23 5 20 1 82 6 24 5 20 1 90 6 91 5 20 1 80 6 23 5 20 1 82 6 35 5 20 1 90 6 91 5 20 1 83 6 40 5 20 1 91 6 96 5 20 1 92 7 08 5 20 1 92 7 08 5 20 1 93 7 17 5 20 1 92 7 08 5 20 1 93 7 17 5 20 1 94 7 18 5 20 1 92 7 08 5 20 1 93 7 17 5 20 1 94 7 30 2 72 1 21 3 76 3 40 1 21 4 05 4 2...

Page 18: ...3 34 3 70 4 02 2 96 3 31 2 00 1 88 1 68 1 45 1 33 1 22 2 22 2 00 1 74 1 60 1 47 2 55 2 24 2 07 2 86 2 11 1 90 1 67 1 54 1 42 2 43 2 15 2 00 2 76 2 24 2 00 2 00 1 82 1 60 1 48 2 33 2 07 1 93 2 15 1 93 2 00 2 00 2 36 2 96 3 65 4 01 4 34 2 22 2 80 3 48 3 84 4 17 2 55 3 20 3 55 2 86 2 11 2 68 3 33 3 69 4 03 2 43 3 08 3 43 2 76 2 24 2 86 2 00 2 54 3 20 3 56 2 33 2 97 3 31 2 15 2 76 2 00 Capacity of eac...

Page 19: ...0 50 20 60 20 71 25 25 25 35 25 50 25 60 25 71 35 35 35 50 35 60 35 71 50 50 50 60 50 71 60 60 60 71 71 71 20 20 20 20 20 25 20 20 35 20 20 50 20 20 60 20 20 71 20 25 25 20 25 35 20 25 50 20 25 60 20 25 71 20 35 35 20 35 50 20 35 60 20 35 71 20 50 50 20 50 60 20 50 71 20 60 60 25 25 25 25 25 35 25 25 50 25 25 60 25 25 71 25 35 35 25 35 50 25 35 60 25 35 71 25 50 50 25 50 60 25 60 60 35 35 35 35 35...

Page 20: ...s of indoor units Total capacity kW Rated Min _Max Total power consumption W Rated Min _Max Total current A Rated Min _Max A room B room C room D room E room 1 32 2 46 2 39 2 31 2 27 2 07 2 33 2 27 2 08 1 91 2 00 1 85 1 71 1 72 1 60 3 14 2 92 2 69 2 48 2 60 2 41 2 24 2 26 3 33 2 00 2 00 2 00 1 82 1 67 1 53 2 00 2 00 1 74 1 60 1 47 1 82 1 60 1 48 1 37 1 43 1 33 2 00 1 90 1 67 1 54 1 42 1 74 1 54 1 ...

Page 21: ... 3 470 2 440 480 3 440 2 430 470 3 360 2 440 480 3 370 2 500 490 3 550 2 430 480 3 430 2 420 480 3 400 11 6 2 0 14 6 11 5 1 9 14 4 11 1 1 9 13 9 11 3 1 9 14 2 11 0 1 9 13 8 10 0 2 0 14 7 10 6 2 0 14 9 11 3 2 0 15 5 12 1 2 0 15 3 11 7 2 0 14 7 11 3 2 0 16 0 12 1 2 0 15 3 11 9 2 0 15 0 11 5 1 9 14 5 11 6 2 0 14 6 11 5 1 9 14 4 11 1 1 9 13 9 11 3 1 9 14 2 11 0 1 9 13 8 11 9 2 0 15 7 11 9 2 0 15 0 11 ...

Page 22: ...MEMO MEMO ...

Reviews: