background image

17

18

Cooling 

only

Heat 

pump

Horizontal Flow

0

°

0

°

Settable to 5 different levels 
between 0

°

 and 35

°

Settable to 5 different levels 
between 0

°

 and 60

°

Settable to 5 different levels 
between 25

°

 and 60

°

Auto-swing 
between 0

°

 and 35

°

Auto-swing 
between 0

°

 and 60

°

Auto-swing 
between 25

°

 and 60

°

Draft 
prevention 
setting

(Set on site)

(Set on site)

Standard 
setting

Setting to 
prevent 
soiling of 
ceiling

Conditioned air is distributed 
evenly by Auto-swing 
operation.

Adjustable airflow angle to 
suit all room conditions.

AUTO-SWING

0

°

0

°

0

°

25

°

60

°

60

°

0

°

35

°

25

°

60

°

35

°

60

°

5 directions

Note: Angles shown above are provided as a guide. They may differ depending on the installation site.

Even for modules other than 600 x 600, no inspection 
opening is required. Maintenance can be performed after 
simply removing the grille, because the switchbox is built 
into the unit.

T-bar grid does not need to be cut

575 

mm

575 

mm

700 

mm

700 

mm

286 

mm

Compact 

decoration panel

T bar

600 

mm

600 

mm

Ceiling panel

Spiral hub cover

At low fan speeds, the 2.5 
kW model produces sound 
of only 24.5 dB (A), and 
even the 6.0 kW model as 
low as 32 dB (A). This is due 
to a spiral hub cover that 
reduces internal airflow 
resistance.

Option

Option

Wireless remote 
controller and signal 
receiver unit are 
sold as a set.

Signal receiver unit

Wireless LCD 
remote controller

Wired LCD 
remote controller

5.0 

kW class

FFQ50BV1B

FFQ50BV1B

3.5 

kW class

FFQ35BV1B

FFQ35BV1B

2.5 

kW class

FFQ25BV1B

FFQ25BV1B

6.0 

kW class

FFQ60BV1B

FFQ60BV1B

FFQ25

29.5/

24.5

 dB(A)

FFQ35

32/

25

 dB(A)

FFQ50

36/

27 

dB(A)

FFQ60

41/

32

 dB(A)

(H/

L

)

4-way flow

1 pattern

3-way flow

4 patterns

2-way flow

1 pattern

"    " denotes piping direction.  "          " denotes sealing member for air discharge
 outlet (option).

Note: For 3-way or 2-way flow installation, the sealing member for air 

discharge outlet (option) must be used to close off the unused outlet(s).

Air discharge patterns can be selected 
according to installation.

Multi-Flow System

Quiet sound level of only 24.5 dB (A)

Two selectable temperature sensors

Both indoor unit and wired remote controller (option) 
contain temperature sensors. Temperature sensing 
can be set at the unit or, to further improve comfort 
level, closer to the target area at the wired remote 
control. This feature requires initial setting by the 
installer.

*Temperature sensor on indoor unit must be used when the air conditioner 

is controlled from another room.

  (Wireless remote controller does not have a temperature sensor.)

If there is a power failure while the unit is operating, 
the system will restart in the same mode when 
power is restored.

Auto-restart

When the filter requires cleaning, the filter icon is 
displayed on the remote controller.

Filter sign

Programme "Dry"

Programme Dry gives priority to reducing the level of
humidity rather than room temperature.  
Dehumidification is computer controlled to prevent 
abrupt and uncomfortable changes in air temperature.

Switchable fan speed: High/Low

Uncomfortable cold air draft is not discharged when 
heating operation starts or when switching to heat 
after defrosting.

Hot start (after defrost)

Note: 
Operation sound   
increases when using 
2-way or 3-way flow.

Provided with drain pump

750 mm

Daikin's innovative air discharge mechanism keeps 
airflow away from the ceiling. Ceiling cleaning is 
required less frequently.

Ceiling soiling prevention function

Compact Multi Flow Ceiling-Mounted Cassette Type

Low draft performance
designed for your comfort

Designed to fit 600 mm wide 
ceiling grids

Comfortable across all areas

Indoor unit lineup

Indoor unit lineup

Less draught

*

* Heat pump only

Summary of Contents for 3MKS58L

Page 1: ...rganization DAIKIN INDUSTRIES THAILAND LTD Scope of Registration THE DESIGN DEVELOPMENT AND MANUFACTURE OF AIR CONDITIONERS AND THE COMPONENTS INCLUDING COMPRESSORS USED FOR THEM All of the Daikin Group s business facilities and subsidiaries in Japan are certified under the ISO 14001 international standard for environment management Warning Daikin products are manufactured for export to numerous c...

Page 2: ... so it is easy to select a model that blends in unobtrusively A single compact outdoor unit allows you to make more efficient use of available space in the installation location such as a balcony The individual indoor units in different rooms the living room study and bedrooms for example can be controlled independently to match your family s lifestyle Super Multi NX can make your home more comfor...

Page 3: ...y efficient 5MK X S series The DC motor swing compressor and other advanced technologies make for energy efficient operation that achieves high COPs The quiet operation mode helps create a more pleasant living environment DC inverter power control provides comfortable temperature control The wide range of indoor unit options provides ample choice A single compact outdoor unit reduces installation ...

Page 4: ...nger magnetic force produced is beneficial particularly at low load conditions 1 A neodymium magnet is approximately 10 times stronger than a standard ferrite magnet 2 The torque created by the change in power between the iron and magnet parts Note Data are based on studies conducted under controlled conditions at a Daikin laboratory Neodymium magnets are used in the pink coloured area 1 2 3 Indoo...

Page 5: ...er rooms may decrease slightly Priority Room Setting also allows Outdoor Unit Quiet Operation to be selected by one command from the priority room If Priority Room Setting has not been set the Outdoor Unit Quiet Operation button must be pushed on the wireless remote controller of all indoor units operating at that time Convenient remote controllers Preferential air conditioning Priority setting wi...

Page 6: ...pe Compact multi flow ceiling mounted cassette type 700 mm width 900 1 100 mm width Cooling only Possible combinations for indoor and outdoor units Heat pump Model Capacity class Model Capacity class Connectable to up to 5 indoor units 2 0 kW 7 1 kW 6 0 kW 5 0 kW 3 5 kW 2 5 kW 2 0 kW 3MKS58L 3MKS68L 4MKS80L 3MXS52L 3MXS68L 4MXS80L Option 5MKS100L 5MXS100L Cooling only Heat pump 5MKS100LVMA 5MXS100...

Page 7: ...ful for preventing circuit breakers from being overloaded by the use of multiple air conditioners and other electrical devices The function is easily activated from the remote controller by pushing the ECONO button This diagram is a representation for illustrative purposes only Maximum capacity decreases during Econo Mode requiring more time to reach the set temperature Running current and power c...

Page 8: ... Purifying Filter Bacteria Removal Test Testing method dropping method Result certificate No 012553 1 and 012553 2 Testing organisation Japan Spinners Inspecting Foundation Clean air Internal structure 3D ait filter catches dust Titanium apatite photocatalytic air purifying filter The remote controller with a backlit liquid crystal display and luminescent control buttons also features a built in W...

Page 9: ... duct Suspension bolt Air discharge grille Signal receiver wire Length 1 900 mm Chamber 700 mm width type 900 1 100 mm width type CDK X S25 35EA 2 5 kW class 3 5 kW class 5 0 kW class 6 0 kW class Cooling only Heat pump CDKS25EAVMA CDXS25EAVMA CDKS35EAVMA CDXS35EAVMA Cooling only Heat pump CDKS25CVMA FDXS25CVMA CDKS35CVMA FDXS35CVMA CDKS50CVMA FDXS50CVMA CDKS60CVMA FDXS60CVMA Duct Connected Type S...

Page 10: ...r discharge outlet option Note For 3 way or 2 way flow installation the sealing member for air discharge outlet option must be used to close off the unused outlet s Air discharge patterns can be selected according to installation Multi Flow System Quiet sound level of only 24 5 dB A Two selectable temperature sensors Both indoor unit and wired remote controller option contain temperature sensors T...

Page 11: ...ndoor unit Wall mounted type FTK X S20 25 35 CDK X S FDXS FTK X S50 60 71 Floor standing type Floor ceiling suspended dual type FVXS FLXS Compact multi flow ceiling mounted cassette type FFQ Duct connected type Power Airflow Dual Flaps Comfortable Airflow Wide Angle Louvres 3 D Airflow Comfort Control Indoor Unit Quiet Operation Outdoor Unit Quiet Operation Night Quiet Mode Inverter Powerful Opera...

Page 12: ... effective cooling heating operation Wide Angle Louvres Comfort Airflow Mode Auto Fan Speed Programme Dry Function Automatic Operation Inverter Powerful Operation Priority Room Setting Home Leave Operation Indoor Unit On Off Switch 24 Hour On Off Timer Night Set Mode See pages 12 and 14 This timer can be preprogrammed with settings for day of the week time of day temperature and operation on off A...

Page 13: ...ons H x W x D Machine weight Piping connections Heat insulation Liquid flare Gas flare Drain dB A dB A mm kg mm Heat pump Cooling only FTKS25KVMA FTKS20KVMA FTKS35KVMA 188 399 42 26 23 58 10 FTKS50KAVMA 245 519 44 35 32 60 FTKS60KAVMA 270 572 45 36 33 61 FTKS71KAVMA 290 614 46 37 34 62 ø15 9 White 5 steps quiet and automatic Microcomputer control ø6 4 Both liquid and gas pipes 38 25 22 54 295 x 80...

Page 14: ...d be replaced approximately every 3 years 5 The photocatalytic deodorising filter is a standard accessory It can be reused indefinitely if it is exposed to direct sunlight once every 6 months This accessory is only required if the original filter is damaged or lost etc 6 The air purifying filter is a standard accessory It should be replaced approximately once every 3 months This accessory is requi...

Page 15: ... 9 9 3 0 14 9 9 4 2 8 15 0 9 4 3 0 15 0 9 4 3 2 15 6 9 4 3 2 15 6 9 1 2 9 15 6 10 1 2 1 13 4 10 1 2 3 13 7 9 9 2 4 13 7 9 3 2 5 14 4 9 1 2 6 15 0 9 1 2 8 15 0 10 1 2 3 14 3 9 9 2 4 14 3 9 3 2 5 15 0 9 1 2 6 15 0 9 1 2 8 15 0 9 9 2 6 14 3 9 1 2 6 15 0 4MKS80LVMA Combinations of indoor units Total capacity kW Rated Min _Max Total power consumption W Rated Min _Max Total current A Rated Min _Max Outd...

Page 16: ...0 1 84 3 18 2 80 2 59 2 40 3 57 3 33 2 50 2 38 2 08 1 92 1 77 3 04 2 69 2 50 2 32 3 45 3 23 2 80 2 50 2 33 3 23 2 50 2 27 2 00 1 85 1 71 2 92 2 59 2 41 2 24 3 33 2 00 2 50 3 50 4 54 4 99 5 41 2 50 3 50 4 35 4 80 5 22 3 18 4 00 4 45 4 86 3 57 4 01 2 50 3 34 4 17 4 62 5 04 3 04 3 85 4 28 4 70 3 45 3 87 2 80 3 57 4 01 3 23 2 50 3 19 4 00 4 45 4 87 2 92 3 71 4 15 4 56 3 33 Capacity of each indoor unit...

Page 17: ... 20 35 35 25 25 25 25 25 35 20 20 50 2 00 1 63 2 95 2 50 1 63 3 24 3 50 1 65 4 52 5 00 1 77 5 84 4 00 1 80 5 96 4 50 1 80 6 23 5 20 1 82 6 24 5 20 1 90 6 91 5 20 1 80 6 23 5 20 1 82 6 35 5 20 1 90 6 91 5 20 1 83 6 40 5 20 1 91 6 96 5 20 1 92 7 08 5 20 1 92 7 08 5 20 1 93 7 17 5 20 1 92 7 08 5 20 1 93 7 17 5 20 1 94 7 18 5 20 1 92 7 08 5 20 1 93 7 17 5 20 1 94 7 30 2 72 1 21 3 76 3 40 1 21 4 05 4 2...

Page 18: ...3 34 3 70 4 02 2 96 3 31 2 00 1 88 1 68 1 45 1 33 1 22 2 22 2 00 1 74 1 60 1 47 2 55 2 24 2 07 2 86 2 11 1 90 1 67 1 54 1 42 2 43 2 15 2 00 2 76 2 24 2 00 2 00 1 82 1 60 1 48 2 33 2 07 1 93 2 15 1 93 2 00 2 00 2 36 2 96 3 65 4 01 4 34 2 22 2 80 3 48 3 84 4 17 2 55 3 20 3 55 2 86 2 11 2 68 3 33 3 69 4 03 2 43 3 08 3 43 2 76 2 24 2 86 2 00 2 54 3 20 3 56 2 33 2 97 3 31 2 15 2 76 2 00 Capacity of eac...

Page 19: ...0 50 20 60 20 71 25 25 25 35 25 50 25 60 25 71 35 35 35 50 35 60 35 71 50 50 50 60 50 71 60 60 60 71 71 71 20 20 20 20 20 25 20 20 35 20 20 50 20 20 60 20 20 71 20 25 25 20 25 35 20 25 50 20 25 60 20 25 71 20 35 35 20 35 50 20 35 60 20 35 71 20 50 50 20 50 60 20 50 71 20 60 60 25 25 25 25 25 35 25 25 50 25 25 60 25 25 71 25 35 35 25 35 50 25 35 60 25 35 71 25 50 50 25 50 60 25 60 60 35 35 35 35 35...

Page 20: ...s of indoor units Total capacity kW Rated Min _Max Total power consumption W Rated Min _Max Total current A Rated Min _Max A room B room C room D room E room 1 32 2 46 2 39 2 31 2 27 2 07 2 33 2 27 2 08 1 91 2 00 1 85 1 71 1 72 1 60 3 14 2 92 2 69 2 48 2 60 2 41 2 24 2 26 3 33 2 00 2 00 2 00 1 82 1 67 1 53 2 00 2 00 1 74 1 60 1 47 1 82 1 60 1 48 1 37 1 43 1 33 2 00 1 90 1 67 1 54 1 42 1 74 1 54 1 ...

Page 21: ... 3 470 2 440 480 3 440 2 430 470 3 360 2 440 480 3 370 2 500 490 3 550 2 430 480 3 430 2 420 480 3 400 11 6 2 0 14 6 11 5 1 9 14 4 11 1 1 9 13 9 11 3 1 9 14 2 11 0 1 9 13 8 10 0 2 0 14 7 10 6 2 0 14 9 11 3 2 0 15 5 12 1 2 0 15 3 11 7 2 0 14 7 11 3 2 0 16 0 12 1 2 0 15 3 11 9 2 0 15 0 11 5 1 9 14 5 11 6 2 0 14 6 11 5 1 9 14 4 11 1 1 9 13 9 11 3 1 9 14 2 11 0 1 9 13 8 11 9 2 0 15 7 11 9 2 0 15 0 11 ...

Page 22: ...MEMO MEMO ...

Reviews: