Si121291EC
Electrical Box
Removal Procedure
7
2. Remove the electrical
box.
1
Remove the 2 screws
of the earth / ground
wires.
2
Remove the screws on
the terminal board and
disconnect all the
connecting wires and
the power supply wire.
3
Remove the 2 screws
and remove the wire
fixture.
4
Detach the outdoor
temperature thermistor.
5
Remove the screw on
the right side of the
electrical box.