Fan Motor
Si121291EC
12
Removal Procedure
4. Fan Motor
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
Remove the 2 screws
and remove the fan
motor fixing plate.
When reassembling, fit the
lower hooks.
2
Remove the nut and
remove the outdoor fan.
Nut size: M6
When reassembling, align
the
mark of the outdoor
fan with the D-cut section of
the motor shaft.
When reassembling, put the
fan motor lead wire through
the back of the fan motor so
as not to be entangled with
the outdoor fan.
3
Open the 2 hooks and
release the fan motor
lead wire.
4
Remove the 4 screws
and remove the fan
motor.
Fan motor fixing plate
(R12908)
(R5564)
(R17764)
Nut
D-cut
mark
Outdoor fan
10 mm
(0.39 inch)
(R18954)
Lead wire
Outdoor fan
(R12215)
(R17765)
Hook
(R12913)
Fan motor