Removal Procedure
1. Outer Panels
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
Remove the 4 screws
and remove the top
panel.
The illustrations are for 3-
room models as
representative.
2
Remove the 6 screws
of the front panel.
3
Remove the screw of
the shield plate.
4
Unfasten the 2 hooks
and remove the shield
plate.
5
Unfasten the 4 hooks
and remove the front
panel.
Front panel
(R17891)
Top panel
Shield plate
(R11204)
(R17754)
Hook
Hook
(R17755)