![Daikin 3MKS50ESG Service Manual Download Page 8](http://html1.mh-extra.com/html/daikin/3mks50esg/3mks50esg_service-manual_3632196008.webp)
Electrical Box
Si121291EC
6
Removal Procedure
10
Disconnect each
connector.
[S90] : thermistors
[S92] : gas pipe thermistors
[S93] : liquid pipe thermistors
When reassembling, insert
each clamp of the thermistor
harnesses into the holes as
below.
50/58 class
3MXS52KVM, 3MXS52LVMA(9)
40/68 class
3AMX52E4V1B, 3MX52E4V1B
11
Disconnect the
connector [S80].
[S80] : four way valve coil
The cooling only models
have no harness for [S80].
12
Pull out the clamp of the
thermistor lead wire.
Step
Procedure
Points
(R5523)
[S90]
[S92]
[S93]
(R20760)
For [S90]
For [S92]
For [S93]
(R20761)
For [S90]
For [S92]
For [S93]
(R5526)
[S80]
Thermistor lead wire
(R18635)
Fixing position for the
thermistor harness
When reassembling, insert
the clamp into the small
hole.