Indoor Unit
SiBE121123_A
31
Printed Circuit Board Connector Wiring Diagram
1.2
CTXS15/35K2V1B, FTXS20/25K2V1B
Control PCB
Caution
Replace the PCB if you accidentally cut the jumpers other than JA, JB, and JC.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of
them.
1) S6
Connector for swing motor (horizontal blade)
2) S25
Connector for INTELLIGENT EYE sensor PCB
3) S26
Connector for display PCB
4) S32
Connector for indoor heat exchanger thermistor
5) S200
Connector for fan motor
6) S403
Connector for adaptor PCB (option)
7) FG1, FG2
Connector for terminal board (frame ground)
8) H1, H2, H3
Connector for terminal board (indoor - outdoor transmission)
9) V1
Varistor
10)JA
Address setting jumper
∗
Refer to page 226 for detail.
11)JB
Fan speed setting when compressor stops for thermostat OFF
JC
Power failure recovery function (auto-restart)
∗
Refer to page 230 for detail.
12)LED A
LED for service monitor (green)
13)FU1 (F1U)
Fuse (3.15 A, 250 V)
FU1
FG1, FG2
LED A
S200
2P297453-1
S32
S26
S6
JA JC JB
S25
S403
H2
H3
H1
V1