SiBE121123_A
Code Indication on Remote Controller
Service Diagnosis
156
4.3
Outdoor Unit
: Displayed only when system-down occurs.
Error Codes
Description
Reference
Page
System
00
Normal
—
U0
Refrigerant shortage
178
U2
Low-voltage detection or over-voltage detection
180
U4
Outdoor unit PCB abnormality or signal transmission error
182
UA
Unspecified voltage (between indoor unit and outdoor unit)
185
UH
Anti-icing control in other room
185
Outdoor
Unit
A5
Anti-icing control for indoor unit
186
E5
OL activation (compressor overload)
188
E6
Compressor lock
190
E7
DC fan lock
191
E8
Input overcurrent detection
192
F3
Discharge pipe temperature control
193
F6
High pressure control in cooling
194
H0
Compressor system sensor abnormality
195
H6
Position sensor abnormality
196
H8
DC voltage / current sensor abnormality
198
H9
Outdoor temperature thermistor or related abnormality
199
J3
Discharge pipe thermistor or related abnormality
199
J6
Outdoor heat exchanger thermistor or related abnormality
199
J8
Liquid pipe temperature thermistor or related abnormality
199
J9
Gas pipe temperature thermistor or related abnormality
199
L3
Electrical box temperature rise
201
L4
Radiation fin temperature rise
202
L5
Output overcurrent detection
204
P4
Radiation fin thermistor or related abnormality
199