![background image](http://html1.mh-extra.com/html/daikin/2mkc30qvm4/2mkc30qvm4_service-manual_3289060011.webp)
Si121656E
Electrical Box / PCB
Removal Procedure
9
6
Disconnect the 2
connectors for the
reactor.
7
Remove the 2 screws
of the electrical box.
8
Lift up the electrical box
and remove it.
When reassembling, make
sure to fit the rear hook.
Step
Procedure
Points
Brown
Orange
Reactor
(R23621)
(R23622)
Electrical box
(R23623)
Hook