background image

General Information

www.DaikinApplied.com 

IM 916-5 • MICROTECH COMMUNICATION MODULE

General Information

 NOTICE

Use this manual to physically install the communication module into the 

unit controller and connect the Applied Air Handling unit controller to your 

network. Use the appropriate Engineering Data (ED), known as the Protocol 

Information document, to integrate the unit into your network. The Protocol 

Information document contains addressing details, BACnet protocol 

information, and a list of the data points available to the network. See 

the Reference Documents section of this manual for Protocol Information 

document numbers. Unit control integration literature is available from your 

local Daikin Sales Representative and www.DaikinApplied.com.

 NOTICE

This equipment generates, uses and can radiate radio frequency energy 

and, if not installed and used in accordance with this instruction manual, 

may cause interference to radio communications. It has been tested and 

found to comply with the limits for a Class A digital device, pursuant to 

part 15 of the FCC rules. These limits are designed to provide reasonable 

protection against harmful interference when the equipment is operated in a 

commercial environment. Operation of this equipment in a residential area 

is likely to cause harmful interference in which case the user will be required 

to correct the interference at his or her own expense. Daikin disclaims any 

liability resulting from any interference or for the correction thereof.

Hazardous Information Messages

 CAUTION

Cautions indicate potentially hazardous situations, which can result in 

personal injury or equipment damage if not avoided. 

 WARNING

Warnings indicate potentially hazardous situations, which can result in 

property damage, severe personal injury, or death if not avoided. 

 WARNING

Warning indicates potentially hazardous situations for PVC (Polyvinyl 

Chloride) and CPVC (Clorinated Polyvinyl Chloride) piping in chilled water 

systems. In the event the pipe is exposed to POE (Polyolester) oil used 

in the refrigerant system, the pipe can be chemically damaged and pipe 

failure can occur.

 

DANGER

Dangers indicate a hazardous electrical situation which will result in death 

or serious injury if not avoided.

 

DANGER

Dangers indicate a hazardous gas situation which will result in death or 

serious injury if not avoided.

 NOTICE

Notices give important information concerning a process, procedure, 

special handling or equipment attributes.

Revision History

IM 916

Oct 2008

Initial release

IM 916-1

May 2009

Modified Step 5 of “To Configure the Module using 

the Keypad/Display” section. Additional steps 

were added to describe how to properly set Given 

IP Address, Given IP Mask, or Given IP Gateway.

IM 916-2

Oct 2009

Added Maverick II (MPS) model. Additional 

changes to keypad display for new global 

navigation menu.

IM 916-3

Aug 2010

Removed note regarding about needing a 

crossover cable. Updated BSP in Table 1 to 

v1.1.30s.

IM 916-3

Mar 2012

•  Update Daikin logo and references. Added 

Rebel to cover.

•  Added step to turn OFF Control Mode on 

HMI prior to installing a new module on unit 

controller.

•  Removed NC Dev3 and RcvHrtBt from the 

Network Configuration Menu table these are no 

longer used.

•  Added AHU Loc/Net, Comm Status and 

RstOutOfSrvc to the Network Configuration 

Menu table

•  Changed BACnetBSP Initial Value in the 

Network Configuration Menu table to 9.26

IM 916-4

Dec 2019

Rebranded layout and added MicroTech 4 Rebel 

Applied. Other minor corrections.

IM 916-5

Aug 2020

OM 1288 added to Reference Documents

Reference Documents

Number

Company

Title

Source

ANSI/

ASHRAE 

135-2001

American Society 

of Heating, 

Refrigerating and 

Air-Conditioning 

Engineers

BACnet, a Data 

Communication 

Protocol for Building 

Automation and Control 

Networks

www.ashrae.org

OM 1288

Daikin Applied 

MicroTech 4 Rebel 

Applied™ Unit 

Controller Operation 

Manual

www.

DaikinApplied.

com

OM 920

MicroTech III Unit 

Controller Operation 

Manual for Applied 

Rooftop and Self-

Contained Systems

ED 19117

MicroTech 4 Rebel 

Applied Unit Controller 

Network Integration 

Guide, BACnet and 

LONWORKS Networks

ED 15112

MicroTech III Rooftop 

and Self Contained 

Unit Controller 

Network Integration 

Guide, BACnet and 

LONWORKS Networks

Limited Warranty

Consult your local Daikin Representative for warranty 

details. To find your local Daikin Representative, go to 

www.DaikinApplied.com.
Copyright ©2020 Daikin Applied Americas, Minneapolis MN. All 

rights reserved throughout the world.
Daikin reserves the right to change any information contained 

herein without prior notice. The user is responsible for 

determining whether this software is appropriate for his or her 

application.
®™ The following are tradenames or registered trademarks of 

their respective companies. BACnet from the American Society 

of Heating, Refrigerating and Air-Conditioning Engineers, 

Summary of Contents for 090016709

Page 1: ...p Controls Part Number IM 916 Date August 2020 BACnet IP Communication Module for MicroTech III and MicroTech 4 Unit Controllers Applied Rooftop Systems and Self Contained Units Models DPS DPH MPS RAH RCE RCS RDE RDS RDT RFS RPE RPS SWP and SWT ...

Page 2: ...ght Emitting Diodes LEDs 5 BACnet Network Connector 5 Board to Board Connector 5 Installation 6 Installation and Mounting 6 Field Installation Kit 6 Installing a new Communication Module 6 Replacing a Communication Module 6 Integration 6 Configuring the BACnet Communication Module 7 BACnet IP Addressing 7 Configurable Parameters 7 Service Information 9 Troubleshooting 9 Parts 9 Technical Support 9...

Page 3: ...eath or serious injury if not avoided NOTICE Notices give important information concerning a process procedure special handling or equipment attributes Revision History IM 916 Oct 2008 Initial release IM 916 1 May 2009 Modified Step 5 of To Configure the Module using the Keypad Display section Additional steps were added to describe how to properly set Given IP Address Given IP Mask or Given IP Ga...

Page 4: ...ature numbers and locations Specifications General Dimensions W x H x D 1 77 x 4 33 x 2 95 in 45 x 110 x 75 mm Weight 3 5 oz 98 g Material Base plastic pigeon blue Housing plastic light gray Operating Temperature 40 158 F 40 70 C Humidity 90 RH Atmospheric pressure Min 10 psi 70kPa corresponding to max 9 842 ft 3 000 m above sea level Storage and Transportation Temperature 40 158 F 40 70 C Humidit...

Page 5: ...flashing with 2Hz Software error1 Red Hardware error1 1 In the event that this should occur cycle power to the unit controller to attempt to clear the problem Contact the Controls Customer Support Group at 866 462 7829 for additional assistance if necessary BUS LED The BUS LED indicates the communication status between the BACnet communication module and the BACnet IP network Table 2 describes the...

Page 6: ...r tool to the tab on the bottom of the unit controller and pull the screwdriver away from the controller 5 Carefully remove the blue plastic knockout on the far right side of the BACnet communication module 6 Insert the board to board connector into the BACnet communication module Note that it only fits one way and that the baffles must line up with corresponding slots in BACnet communication modu...

Page 7: ...ntered a password skip to step 3 2 Enter Password 6363 3 Continue to navigate to the BMS Communications BACnet IP Set Up menu NOTE The IP Setup menu only appears if a BACnet communication module installed correctly If the BACnet communication module is installed correctly and this menu still does not appear cycle power to the unit controller and repeat the procedure from Step 3 above 4 Modify the ...

Page 8: ...et Mask Gvn Msk provided the network is connected when Apply Changes is set to Yes Act Gwy If DHCP set to On Address automatically assigned by network If DHCP set to Off Address Given Gateway Address Actual Gateway Address Item remains blank if the network is not connected when power is applied to the unit controller If DHCP is set to On the network automatically assigns this address If DHCP is se...

Page 9: ...onfirm that the DHCP parameter is set to Off when a static IP address is being used for non DHCP networks Check that the defined UDP port e g BAC0 is open in the firewall Verify if BBMDs are required BBMD must be used if the BACnet client and BACnet server are located on different subnets Use the command tracert to check this Tracert shows all stations used to forward the signal to another segment...

Page 10: ...Identifier or their BACnet address The IP address is part of the BACnet address and may not be changed for the alarm recipient For this reason option Device Object Identifier must always be used Access rights If access rights are assigned based on IP address such as firewalls the address must be static Access rights are based off of the UDP Port Number ex UDP 47808 or the MAC Address of the BACnet...

Page 11: ......

Page 12: ...ant to its standard terms and conditions of sale including Limited Product Warranty Consult your local Daikin Applied Representative for warranty details To find your local Daikin Applied Representative go to www DaikinApplied com Aftermarket Services To find your local parts office visit www DaikinApplied com or call 800 37PARTS 800 377 2787 To find your local service office visit www DaikinAppli...

Reviews: