7.2 Welding Result Control Function
This section explains about the welding result control function. The function enables the management of
the items below.
Details of control contents (
Details of welding control items)
7.2.1
Setting welding result control function
This section explains how to set the welding result control function.
1.
Press and hold the WELD MONITOR key for one second or more.
Welding control
parameter
Monitor
No.
Initial
value
Setting range
Explanation
Number of welding
point
P10
0
-
Cumulative number of welding points (number of times)
P11
0
0 to 999
Target value of welding points (number of times)
P12
0
0 to 5
Operation at the time when the target value of welding points
is achieved
Wire consumption
P20
0.00
-
Cumulative wire consumption used in welding [lbs (kg)]
P21
0
0 to 999
(0 to 453)
Target wire consumption [lbs (kg)]
P22
0
0 to 5
Operation at the time when the target wire consumption is
achieved
Total welding time
P30
0
-
Cumulative total welding time (minute)
P31
0
0 to 999
Target total welding time (minute)
P32
0
0 to 5
Operation at the time when the target total welding time is
achieved
Welding monitor
P40
0
-
Max. fluctuation value of average range monitor (A or V)
P41
100
0 to 100
Current tolerance (+) (%)
P42
100
0 to 100
Current tolerance (-) (%)
P43
100
0 to 100
Voltage tolerance (+) (%)
P44
100
0 to 100
Voltage tolerance (-) (%)
P45
0
0 to 100
WARNING judgment time (second)
P46
0
0 to 2
Operation at the time of WARNING detection
⇒
The LED of WELD MONITOR key lights up.
⇒
The monitor No. is displayed on the left digital
meter.
⇒
The data value specified for the monitor No. is
displayed on the right digital meter.
A
V
r
㧑
WARNING
IPM.
sec.
JOB No.
WELD
MONITOR
Hz