S
ETTING
I
NTERNAL
F
UNCTIONS
W
ELDING
C
ONDITION
C
HAPTER
6
6-42
6.7.2.32 F48: Adjusting current with torch switch
Increases/decreases the welding current by the torch switch operation.
•
[ON]: the setting of "CRATER-FILL ON" is selected, enabling to increase or decrease welding current by
single-clicking or double-clicking the torch switch in the period of welding condition (during start input
holding)
If this function is enabled, the LED of "CRATER-FILL ON" of the CRATER-FILL key flashes.
Set the increase/decrease current volume through F49 (Current increase and decrease by single-clicking)
and F50 (Current increase and decrease by double-clicking).
•
[OFF]: disables the function.
T I P S
• When the internal function F45 is set to [ON], automatically the setting of "CRATER-FILL
ON" is selected, disabling other welding modes. (The CRATER-FILL key does not work.)
• Setting for current increase and decrease is available for both single-clicking and
doubleclicking.
• Single-clicking or double-clicking operation should be within 0.3 seconds.
• At the time of transition to crater, press the torch switch for at least 0.3 seconds.
• Welding method at crater treatment is the same as that of main welding.
Example:
In the setting examples of Crater setting: ON; Initial condition: OFF; Welding current: 100 A; Crater
current: 60 A; F48: "ON"; F49:"-10"; and F50: "20", the following diagram is available:
•
In the following cases, this function cannot be used:
–
An analog remote control (optional) is connected.
–
Internal function F11 (Fine adjustment of welding conditions memory) is set to "1" to "30" (enabled);
–
Internal function F44 (Reading welding condition with remote control) is set to "ON" (enabled);
–
Internal function F45 (Special crater sequence) is set to "ON" (enabled);
–
Internal function F51 (Special crater repeat) is set to "ON" (enabled); or
–
Either of the internal functions F29 to F32 (External input terminal setting) is set to either "4" (Start) or
"5" (Loading welding condition).
100 A
90 A
80 A
100 A
90 A
110 A
100 A
60 A
Press 0.3 sec. or more
Single
(within 0.3 sec.)
Double
(within 0.3 sec.
x 2 times)
ON
OFF
Within
0.3 sec.
Torch switch
Welding current
Crater-fil
㫃
Main welding
Within
0.3 sec.