3. Product Usage       

                                                                                                             

      3.1 Precautions for Use

You must read this manual carefully and completely before using.
The device should only be operated by laboratory personnel especially trained for 
this purpose and familiar with all precautionary measures required for working in a 
laboratory.

Be careful not to drop when transporting the product.

Place the device on a level, horizontal surface to support the capacity of the 
device without vibration. If there is vibration, install the device on a support 
material with enough space. Small place may cause the device to drop.

Please never tilt or lay the product doing during transportation.

Do not install at a dangerous place.
Do not operate the device where there are flammables. It could be caused serious 
accidents like explosion or fire.

Do not use outdoors avoid overheating or electrical fault. The use in the place 
where the sun continuously shines and can get rained on it is prohibited. It may 
cause overheating or electrical fault of the product.

This product was manufactured to move normally at the rated voltage.
Confirm the voltage state before the installation of product.
(AC 230V, 50/60Hz, Single phase)

Do not install the product where it can get damp or in a dusty environment.
It may cause overheating or short circuit. (Pollution Degree 2)

If the product was moved or stored in high humidity state, identify the packaging 
state of the product before use.
In case that the carton box or wooden box is soaked in water, consult with an 
engineer about the matter. Do not operate the equipment before the safety is 
confirmed. This wetting state may be the cause of an electric shock or a fire.
This product should be operated in a room with temperature maintain between 5

and 40

. Long-term use in an environment that exceeds the allowable range may 

cause a malfunction.
The maximum relative humidity is 80% at 31

and 50% at 40

.

Do not install the product in a location at an altitude of over 2,000 meters. (6,562 
feet).
The Sound Level of the buzzer is maximum 60dB in 1 meter distance when an 
error is detected.
Do not install the product at gloomy place.
If the product is installed at gloomy place, the unexpected accident by the 
movement mistake may occur.

3

Summary of Contents for MaXtable H20

Page 1: ...ed Validation IQ OQ Service Patented Patent No 10 0554098 Jog Shuttle Control System User Manual Version 2 2 1 written for MaXtableTM H20 MaXtableTM H20 High Performance Dry Bath Heating Block DAIHAN...

Page 2: ...Use 3 1 2 Product Introduction 4 1 3 Product Configuration 5 2 Installation 2 1 Product Installation 6 2 2 Product Specifications 7 3 Product Usage 3 1 Precautions for Use 10 3 2 Names of Each Part 1...

Page 3: ...he meaning Warning If the product is mishandled while ignoring this symbol the danger by which human beings are dead or severely injured may occur Caution Failure to follow the instructions may result...

Page 4: ...r entire interval of broad range of temperature The product thus can be applicable to various labs in diverse disciplines and has the following features 1 The Digital Feedback Control controlled by th...

Page 5: ...product is furnished with functions capable of protecting the overheating overcurrent and sensor errors of the product to secure the safety of users 9 The product is furnished with various kinds of b...

Page 6: ...together with the product is damaged and connect it with the product 4 Insert the socket in the other side into the wall plug In case of using a power strip be careful not to exceed the electrical en...

Page 7: ...uct Specifications Models MaXtableTM H20 Only Unit MaXtable TM H20 set included Standard Block Controller Single Digital Fuzzy Controller Useful Block Interchangeable Block 90 120 h60mm for Various Tu...

Page 8: ...t may cause overheating or electrical fault of the product This product was manufactured to move normally at the rated voltage Confirm the voltage state before the installation of product AC 230V 50 6...

Page 9: ...ve sufficient electric capacity The fluctuation of main power voltage should be lower than 10 of the nominal voltage Please separate the power plug from the outlet for safety when the product is unuse...

Page 10: ...the product to other place Please wear the protective equipment because the heating temperature can be overheated above the setting temperature Please always use the safety equipment working clothes...

Page 11: ...ion Power Switch Equipment power ON OFF Fuse Holder Fixing the fuse and protection not to expose Specification sticker Recording the specification and serial number of product Safety symbol sticker De...

Page 12: ...on Mode change button Timer setting mode Temperature setting mode Locking mode LCD Display Display operation information Rotary Switch Turn the clockwise or counterclockwise to adjust the setting valu...

Page 13: ...The range of values of the time set by the timer can be up to 99 time and 59 minutes and the set value will be varying by a unit of 1 minutes 6 Push the Rotary Switch once and shortly then the product...

Page 14: ...se to adjust the set value Press the PUSH button to have the set value fixed on the display The Reservation Timer for reserved operation of product will then begin 4 On completion of the pre setting o...

Page 15: ...value of current temperature whereas the figures displaying on the SV are the values of set temperature 3 Rotate the rotary switch on the controller clockwise or counterclockwise to adjust the set va...

Page 16: ...eleasing the MODE button 3 The scope of the compensative value is 10 0 10 0 and it is possible to adjust at 0 1 unit 4 After setting the compensation value the indication of the current temperature is...

Page 17: ...ll be changed into the display of locking mode 2 Accelerating and stop right after the locked display will prevent potential risks of malfunctioning of the product due to unintended turning of Rotary...

Page 18: ...Centrifuge Tube 48 holes DH WHB521248 Block BLT248 for 12mm Test Tube 48 holes DH WHB521335 Block BLT335 for 13mm Test Tube 30 holes DH WHB521535 Block BLT535 for 15mm Test Tube 30 holes DH WHB521628...

Page 19: ...y using driver Identify the fuse and replace it 120V F5AL 250V 230V F3AL 250V Re install the fuse holder to the body while pushing the holder with hands Classifications A period of checking time Day W...

Page 20: ...sed wipe off only the part with the towel wetting with the solvent that has low freezing point 6 If the materials wetted by liquid or water are entered into this product please immediately disconnect...

Page 21: ...t Switch off of the residual current device at the installation place or occurrence of power failure Inaccurate connection between a power plug and a socket Damage of socket plug power cable Disorder...

Page 22: ...cess about all functions before shipment 2 This instrument is warranted for 2 years from purchasing date 3 A breakdown caused by customer s improper use or natural disaster is excepted from this warra...

Reviews: