Operation Manual
177
Table 5-16 Description of people counting parameters
Parameter
Description
OSD
Select the
OSD
checkbox or select the
Enter No.
or
Leave No.
checkbox
under
OSD
to display the people counting data in the image.
Click
Clear
to clear the count.
Flip
Set the viewing angle of the image as
Inclined
or
Vertical
.
Flowrate Alarm
Set
Enter No.
,
Leave No.
, and
Stranded No.
The alarm is triggered when
the configured value is reached.
Regional People
Number Statistics
Alarm
Set the number of people in the people counting region. When the
people count reaches the threshold or the stay duration exceeds the
configured value, the alarm is triggered.
When you set inside number to be 0, and select the type to be
≥
Threshold
, the system will not perform the alarm linkage.
Inside Number
Type
Stranding Alarm
Select the
Stranding Alarm
checkbox, and then set the stranding time,
when the stay duration exceeds the configured value, the alarm will be
triggered.
Stranding Time
Sensitivity
Set the alarm-triggered sensitivity. The higher the sensitivity is, the easier
the alarm will be triggered.
Max Height
Set the maximum height of the people in detection area. The unit is cm,
and the range is 0–300.
Min Height
Set the minimum height of the people in detection area. The unit is cm,
and the range is 0–200.
Step 6
Set arming periods and alarm linkage actions. For details, see "5.1.1 Alarm Linkage".
Step 7
Click
Save
.
To view alarm information on the
Alarm
tab, subscribe relevant alarm event. For details,
see "5.1.2 Subscribing Alarm".
Result
You can view the counting results on the
Live
interface.
●
For
People Counting
rule, the entry and exit numbers are displayed.
●
For
In Area No.
rule, the inside number is displayed.
Summary of Contents for HDBW2831R-ZAS
Page 1: ...Network Camera Web 3 0 Operation Manual ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD V2 1 3...
Page 188: ...Operation Manual 175 Figure 5 64 People counting...
Page 230: ...Operation Manual 217 Select Setting Information Online User Figure 6 12 Online user...
Page 234: ...Operation Manual...
Page 247: ...Quick Start Guide 7 Main interface...
Page 251: ...Quick Start Guide 11 Cable going through the mounting surface...
Page 254: ...Quick Start Guide 14...
Page 255: ......
Page 256: ......