Step 4
Configure the parameters of the doors.
Figure 5-4 Configure door parameters
Table 5-1 Parameter description
Parameter
Description
Entry Card Reader
Select the card reader protocol.
●
Wiegand: Connects to a Wiegand reader. You can connect the
LED wire to the LED port of the controller, and the reader will
beep and flash when the door unlocks.
●
OSDP: Connects to an OSDP reader.
●
RS-485: Connects to a RS-485 reader.
Exit Button
Connects to an exit button.
Door Detector
Connects to a door detector.
Power Supply of Locks
●
12 V: The controller provides power to the lock.
Fail secure: When the power is interrupted or fails, the door
stays locked.
Fail safe: When the power is interrupted or fails, the door
automatically unlocks to let people leave.
●
Relay: The relay supplies power for the lock.
Relay open = locked: Sets the lock to remain locked when the
relay is open.
Quick Start Guide
28