5.7
LUTControl
In this property, you can stretch and highlight the gray-level range of the region of interest. The
operation applies to linear curve as well as customized mapping curve, as shown in Figure 5-7; please
refer to Sheet 5-8 for detailed parameter settings.
LUT: short for Look-Up Table.
LUT and Gamma are mutually exclusive. If Gamma is enabled, LUT will not take effect. If LUT is
enabled, Gamma needs to be set to 1.
Figure 5-7
LUT Control
Sheet 5-8
LUT Control - Parameter Explanation
Parameter
Explanation
LUTSelector
Selects the channel of LUT.
Currently only Luminance
(
brightness
)
Look-Up Table is supported.
LUTEnable
LUT setting.
1.
Enables LUT for LUT lookup table function.
2.
Sets digital points of the lookup table in LUTIndex with range of
0~4095.
3.
When LUTIndex is selected, you can set corresponding values in
LUTValue.
LUTIndex
LUTValue
LUTValueAll
Sets all the values of Index to the same value.
5.8
TransportLayerControl
In this property, you can set parameters related to camera’s transport layer protocol, as shown in Figure
5-8; please refer to Sheet 5-9 for detailed parameter settings.